Analytical methods for the determination of endocrine disruptors, UV filters and plastic additives in packaging and pharmaceuticals
This thesis is presented as a compilation of publications and deals with the development, optimization and validation of different analytical methods to determine in packaging: UV filters by HPLC-DAD, plastic additives by UHPLC-(ToF)MS and perfluorinated compounds by UHPLC-(QToF)MS/MS. In each work,...
Guardado en:
Autor principal: | |
---|---|
Otros Autores: | |
Formato: | text (thesis) |
Lenguaje: | eng |
Publicado: |
Universidad de La Rioja (España)
2015
|
Acceso en línea: | https://dialnet.unirioja.es/servlet/oaites?codigo=46519 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai-TES0000008965 |
---|---|
record_format |
dspace |
spelling |
oai-TES00000089652019-07-19Analytical methods for the determination of endocrine disruptors, UV filters and plastic additives in packaging and pharmaceuticalsMoreta Sánchez, CristinaThis thesis is presented as a compilation of publications and deals with the development, optimization and validation of different analytical methods to determine in packaging: UV filters by HPLC-DAD, plastic additives by UHPLC-(ToF)MS and perfluorinated compounds by UHPLC-(QToF)MS/MS. In each work, a focused ultrasonic solid-liquid extraction (FUSLE), a fast, simple and relatively new extraction technique, is developed and optimized; and its efficiency is evaluated by comparing it with other extraction techniques. Lastly, the developed methods are applied to the analysis of several real samples. In the case of the UV filters method, it was also applied to evaluate the migration and delamination capacities of these analytes through different contact layers in multilayer packaging. Finally, on a line parallel to these works, an analytical method for the determination of parabens in pharmaceuticals by SLE-SPE-UHPLC-(QqQ)MS/MS was developed. Moreover, the optimized method was also applied to the analysis of more than one hundred samples in order to evaluate if the use of medicines may be a source of exposure to parabens. Esta tesis se presenta como compendio de publicaciones y trata del desarrollo, optimización y validación de diferentes métodos de análisis para la determinación en el embalaje de filtros UV por HPLC-DAD, aditivos plásticos por UHPLC-(ToF)MS y compuestos perfluorados por UHPLC-(QToF)MS/MS. En cada trabajo, una extracción sólido-líquido con ultrasonidos focalizados (FUSLE), una técnica de extracción rápida, sencilla y relativamente nueva, es desarrollada y optimizada. Asimismo, la eficacia del método FUSLE es evaluada comparándola con otras técnicas de extracción. Finalmente los métodos desarrollados se aplican para el análisis de varias muestras reales. En el caso del método para determinar filtros UV, también se aplicó para estudiar los procesos de migración y delaminación de los filtros UV en el embalaje flexible multicapa a través de diferentes capas de contacto. Finalmente, en una línea paralela, se desarrolló un método analítico para la determinación de parabenos en productos farmacéuticos por SLE-SPE-UHPLC-(QqQ)MS/MS. Además, el método desarrollado se aplicó para el análisis de más de cien muestras con el fin de evaluar si el consumo de medicamentos puede ser una fuente de exposición a los parabenos.Universidad de La Rioja (España)Tena Vázquez de la Torre, María Teresa (Universidad de La Rioja)2015text (thesis)application/pdfhttps://dialnet.unirioja.es/servlet/oaites?codigo=46519engLICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI |
institution |
DialNet |
collection |
DialNet |
language |
eng |
description |
This thesis is presented as a compilation of publications and deals with the development, optimization and validation of different analytical methods to determine in packaging: UV filters by HPLC-DAD, plastic additives by UHPLC-(ToF)MS and perfluorinated compounds by UHPLC-(QToF)MS/MS. In each work, a focused ultrasonic solid-liquid extraction (FUSLE), a fast, simple and relatively new extraction technique, is developed and optimized; and its efficiency is evaluated by comparing it with other extraction techniques. Lastly, the developed methods are applied to the analysis of several real samples. In the case of the UV filters method, it was also applied to evaluate the migration and delamination capacities of these analytes through different contact layers in multilayer packaging. Finally, on a line parallel to these works, an analytical method for the determination of parabens in pharmaceuticals by SLE-SPE-UHPLC-(QqQ)MS/MS was developed. Moreover, the optimized method was also applied to the analysis of more than one hundred samples in order to evaluate if the use of medicines may be a source of exposure to parabens.
Esta tesis se presenta como compendio de publicaciones y trata del desarrollo, optimización y validación de diferentes métodos de análisis para la determinación en el embalaje de filtros UV por HPLC-DAD, aditivos plásticos por UHPLC-(ToF)MS y compuestos perfluorados por UHPLC-(QToF)MS/MS. En cada trabajo, una extracción sólido-líquido con ultrasonidos focalizados (FUSLE), una técnica de extracción rápida, sencilla y relativamente nueva, es desarrollada y optimizada. Asimismo, la eficacia del método FUSLE es evaluada comparándola con otras técnicas de extracción. Finalmente los métodos desarrollados se aplican para el análisis de varias muestras reales. En el caso del método para determinar filtros UV, también se aplicó para estudiar los procesos de migración y delaminación de los filtros UV en el embalaje flexible multicapa a través de diferentes capas de contacto. Finalmente, en una línea paralela, se desarrolló un método analítico para la determinación de parabenos en productos farmacéuticos por SLE-SPE-UHPLC-(QqQ)MS/MS. Además, el método desarrollado se aplicó para el análisis de más de cien muestras con el fin de evaluar si el consumo de medicamentos puede ser una fuente de exposición a los parabenos. |
author2 |
Tena Vázquez de la Torre, María Teresa (Universidad de La Rioja) |
author_facet |
Tena Vázquez de la Torre, María Teresa (Universidad de La Rioja) Moreta Sánchez, Cristina |
format |
text (thesis) |
author |
Moreta Sánchez, Cristina |
spellingShingle |
Moreta Sánchez, Cristina Analytical methods for the determination of endocrine disruptors, UV filters and plastic additives in packaging and pharmaceuticals |
author_sort |
Moreta Sánchez, Cristina |
title |
Analytical methods for the determination of endocrine disruptors, UV filters and plastic additives in packaging and pharmaceuticals |
title_short |
Analytical methods for the determination of endocrine disruptors, UV filters and plastic additives in packaging and pharmaceuticals |
title_full |
Analytical methods for the determination of endocrine disruptors, UV filters and plastic additives in packaging and pharmaceuticals |
title_fullStr |
Analytical methods for the determination of endocrine disruptors, UV filters and plastic additives in packaging and pharmaceuticals |
title_full_unstemmed |
Analytical methods for the determination of endocrine disruptors, UV filters and plastic additives in packaging and pharmaceuticals |
title_sort |
analytical methods for the determination of endocrine disruptors, uv filters and plastic additives in packaging and pharmaceuticals |
publisher |
Universidad de La Rioja (España) |
publishDate |
2015 |
url |
https://dialnet.unirioja.es/servlet/oaites?codigo=46519 |
work_keys_str_mv |
AT moretasanchezcristina analyticalmethodsforthedeterminationofendocrinedisruptorsuvfiltersandplasticadditivesinpackagingandpharmaceuticals |
_version_ |
1718346636259753984 |