Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails

Abstract This prospective study aimed to introduce the application of the multiplanar fracture redactor (MFR) in the treatment of tibial shaft fractures with intramedullary nails (IMNs). From February to June 2018, a total of 18 patients with tibial shaft fractures were recruited. MFR was used to he...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kuo Zhao, Hongzhi Lv, Chun Zhang, Zhongzheng Wang, Zhiyong Hou, Wei Chen, Qi Zhang, Yingze Zhang
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/013d087f0b1d4edf8c66383a6df00fad
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:013d087f0b1d4edf8c66383a6df00fad
record_format dspace
spelling oai:doaj.org-article:013d087f0b1d4edf8c66383a6df00fad2021-12-02T15:27:05ZApplication of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails10.1038/s41598-021-87913-52045-2322https://doaj.org/article/013d087f0b1d4edf8c66383a6df00fad2021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-87913-5https://doaj.org/toc/2045-2322Abstract This prospective study aimed to introduce the application of the multiplanar fracture redactor (MFR) in the treatment of tibial shaft fractures with intramedullary nails (IMNs). From February to June 2018, a total of 18 patients with tibial shaft fractures were recruited. MFR was used to help achieve the reduction of tibial shaft fractures with IMN in all patients. The demographic and fracture characteristics, surgical data, postoperative complications and prognostic indicators of 16 patients were recorded. All operations were performed under closed reduction, excellent radiological and functional outcomes were observed. The average duration of surgery, intraoperative blood loss, intraoperative fluoroscopy times, number of intraoperative assistants, and duration of postoperative hospital stay were 91.2 ± 26.1 min, 95.0 ± 58.3 ml, 19.2 ± 2.3 times, 1 (1–2), and 7.8 ± 2.6 days, respectively. The mean Lysholm Knee Function Score (LKFS), American Orthopaedic Foot and Ankle Society (AOFAS) and visual analogue scale (VAS) scores at one year after surgery were 96.8 ± 2.1, 94.8 ± 2.9, and 1 (0–3), respectively. Wound infection, non-union, malunion or complications associated with MFR were not observed in this study. Thus, MFR was a safe and neater method to achieve and maintain the reduction of tibial shaft fractures with IMN.Kuo ZhaoHongzhi LvChun ZhangZhongzheng WangZhiyong HouWei ChenQi ZhangYingze ZhangNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Kuo Zhao
Hongzhi Lv
Chun Zhang
Zhongzheng Wang
Zhiyong Hou
Wei Chen
Qi Zhang
Yingze Zhang
Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails
description Abstract This prospective study aimed to introduce the application of the multiplanar fracture redactor (MFR) in the treatment of tibial shaft fractures with intramedullary nails (IMNs). From February to June 2018, a total of 18 patients with tibial shaft fractures were recruited. MFR was used to help achieve the reduction of tibial shaft fractures with IMN in all patients. The demographic and fracture characteristics, surgical data, postoperative complications and prognostic indicators of 16 patients were recorded. All operations were performed under closed reduction, excellent radiological and functional outcomes were observed. The average duration of surgery, intraoperative blood loss, intraoperative fluoroscopy times, number of intraoperative assistants, and duration of postoperative hospital stay were 91.2 ± 26.1 min, 95.0 ± 58.3 ml, 19.2 ± 2.3 times, 1 (1–2), and 7.8 ± 2.6 days, respectively. The mean Lysholm Knee Function Score (LKFS), American Orthopaedic Foot and Ankle Society (AOFAS) and visual analogue scale (VAS) scores at one year after surgery were 96.8 ± 2.1, 94.8 ± 2.9, and 1 (0–3), respectively. Wound infection, non-union, malunion or complications associated with MFR were not observed in this study. Thus, MFR was a safe and neater method to achieve and maintain the reduction of tibial shaft fractures with IMN.
format article
author Kuo Zhao
Hongzhi Lv
Chun Zhang
Zhongzheng Wang
Zhiyong Hou
Wei Chen
Qi Zhang
Yingze Zhang
author_facet Kuo Zhao
Hongzhi Lv
Chun Zhang
Zhongzheng Wang
Zhiyong Hou
Wei Chen
Qi Zhang
Yingze Zhang
author_sort Kuo Zhao
title Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails
title_short Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails
title_full Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails
title_fullStr Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails
title_full_unstemmed Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails
title_sort application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/013d087f0b1d4edf8c66383a6df00fad
work_keys_str_mv AT kuozhao applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails
AT hongzhilv applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails
AT chunzhang applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails
AT zhongzhengwang applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails
AT zhiyonghou applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails
AT weichen applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails
AT qizhang applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails
AT yingzezhang applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails
_version_ 1718387183293825024