Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails
Abstract This prospective study aimed to introduce the application of the multiplanar fracture redactor (MFR) in the treatment of tibial shaft fractures with intramedullary nails (IMNs). From February to June 2018, a total of 18 patients with tibial shaft fractures were recruited. MFR was used to he...
Guardado en:
Autores principales: | , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/013d087f0b1d4edf8c66383a6df00fad |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:013d087f0b1d4edf8c66383a6df00fad |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:013d087f0b1d4edf8c66383a6df00fad2021-12-02T15:27:05ZApplication of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails10.1038/s41598-021-87913-52045-2322https://doaj.org/article/013d087f0b1d4edf8c66383a6df00fad2021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-87913-5https://doaj.org/toc/2045-2322Abstract This prospective study aimed to introduce the application of the multiplanar fracture redactor (MFR) in the treatment of tibial shaft fractures with intramedullary nails (IMNs). From February to June 2018, a total of 18 patients with tibial shaft fractures were recruited. MFR was used to help achieve the reduction of tibial shaft fractures with IMN in all patients. The demographic and fracture characteristics, surgical data, postoperative complications and prognostic indicators of 16 patients were recorded. All operations were performed under closed reduction, excellent radiological and functional outcomes were observed. The average duration of surgery, intraoperative blood loss, intraoperative fluoroscopy times, number of intraoperative assistants, and duration of postoperative hospital stay were 91.2 ± 26.1 min, 95.0 ± 58.3 ml, 19.2 ± 2.3 times, 1 (1–2), and 7.8 ± 2.6 days, respectively. The mean Lysholm Knee Function Score (LKFS), American Orthopaedic Foot and Ankle Society (AOFAS) and visual analogue scale (VAS) scores at one year after surgery were 96.8 ± 2.1, 94.8 ± 2.9, and 1 (0–3), respectively. Wound infection, non-union, malunion or complications associated with MFR were not observed in this study. Thus, MFR was a safe and neater method to achieve and maintain the reduction of tibial shaft fractures with IMN.Kuo ZhaoHongzhi LvChun ZhangZhongzheng WangZhiyong HouWei ChenQi ZhangYingze ZhangNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Kuo Zhao Hongzhi Lv Chun Zhang Zhongzheng Wang Zhiyong Hou Wei Chen Qi Zhang Yingze Zhang Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails |
description |
Abstract This prospective study aimed to introduce the application of the multiplanar fracture redactor (MFR) in the treatment of tibial shaft fractures with intramedullary nails (IMNs). From February to June 2018, a total of 18 patients with tibial shaft fractures were recruited. MFR was used to help achieve the reduction of tibial shaft fractures with IMN in all patients. The demographic and fracture characteristics, surgical data, postoperative complications and prognostic indicators of 16 patients were recorded. All operations were performed under closed reduction, excellent radiological and functional outcomes were observed. The average duration of surgery, intraoperative blood loss, intraoperative fluoroscopy times, number of intraoperative assistants, and duration of postoperative hospital stay were 91.2 ± 26.1 min, 95.0 ± 58.3 ml, 19.2 ± 2.3 times, 1 (1–2), and 7.8 ± 2.6 days, respectively. The mean Lysholm Knee Function Score (LKFS), American Orthopaedic Foot and Ankle Society (AOFAS) and visual analogue scale (VAS) scores at one year after surgery were 96.8 ± 2.1, 94.8 ± 2.9, and 1 (0–3), respectively. Wound infection, non-union, malunion or complications associated with MFR were not observed in this study. Thus, MFR was a safe and neater method to achieve and maintain the reduction of tibial shaft fractures with IMN. |
format |
article |
author |
Kuo Zhao Hongzhi Lv Chun Zhang Zhongzheng Wang Zhiyong Hou Wei Chen Qi Zhang Yingze Zhang |
author_facet |
Kuo Zhao Hongzhi Lv Chun Zhang Zhongzheng Wang Zhiyong Hou Wei Chen Qi Zhang Yingze Zhang |
author_sort |
Kuo Zhao |
title |
Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails |
title_short |
Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails |
title_full |
Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails |
title_fullStr |
Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails |
title_full_unstemmed |
Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails |
title_sort |
application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/013d087f0b1d4edf8c66383a6df00fad |
work_keys_str_mv |
AT kuozhao applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails AT hongzhilv applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails AT chunzhang applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails AT zhongzhengwang applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails AT zhiyonghou applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails AT weichen applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails AT qizhang applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails AT yingzezhang applicationofthemultiplanarfractureredactorinthetreatmentoftibialshaftfractureswithintramedullarynails |
_version_ |
1718387183293825024 |