Textile electrodes for bioimpedance measuring
This article deals with the development and comparison of eight different electrodes made out of a cotton fabric substrate, a silver coated yarn and partly conductive finishes, i.e. a PEDOT:PSS Orgacon ICP 1050 dip-coating and a Powersil coating. The purpose is the application especially in the medi...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
TU Dresden; Faculty of Mechanical Science and Engineering;Chair of Development and Assembly of Textile Products
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/020439e8cf89467693d90610ff714328 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:020439e8cf89467693d90610ff714328 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:020439e8cf89467693d90610ff7143282021-11-08T17:12:34ZTextile electrodes for bioimpedance measuring2701-939X10.25367/cdatp.2021.2.p49-60https://doaj.org/article/020439e8cf89467693d90610ff7143282021-06-01T00:00:00Zhttps://journals.qucosa.de/cdatp/article/view/36https://doaj.org/toc/2701-939XThis article deals with the development and comparison of eight different electrodes made out of a cotton fabric substrate, a silver coated yarn and partly conductive finishes, i.e. a PEDOT:PSS Orgacon ICP 1050 dip-coating and a Powersil coating. The purpose is the application especially in the medical field of angiopathy like for bioimpedance measurements during compression therapies. To be able to compare the suitability of the electrodes, various tests have been performed of the coating abrasion resistance, the stability of electrical resistance values, as well as resistance and bioimpedance measurements. Significant differences between the electrodes regarding their resilience and resistance that are visualized in a value-added analysis were found, with one hand-embroidered, one machine-sewn and one commercial electrode showing optimum properties.Judith Tabea MedingKhorolsuren TuvshinbayarChristoph DöpkeFerdinand TamoueTU Dresden; Faculty of Mechanical Science and Engineering;Chair of Development and Assembly of Textile Productsarticletextile electrodes, bioimpedance measuring, smart textiles, bia, medical textilesTextile bleaching, dyeing, printing, etc.TP890-933Engineering machinery, tools, and implementsTA213-215ENCommunications in Development and Assembling of Textile Products, Vol 2, Iss 1, Pp 49-60 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
textile electrodes, bioimpedance measuring, smart textiles, bia, medical textiles Textile bleaching, dyeing, printing, etc. TP890-933 Engineering machinery, tools, and implements TA213-215 |
spellingShingle |
textile electrodes, bioimpedance measuring, smart textiles, bia, medical textiles Textile bleaching, dyeing, printing, etc. TP890-933 Engineering machinery, tools, and implements TA213-215 Judith Tabea Meding Khorolsuren Tuvshinbayar Christoph Döpke Ferdinand Tamoue Textile electrodes for bioimpedance measuring |
description |
This article deals with the development and comparison of eight different electrodes made out of a cotton fabric substrate, a silver coated yarn and partly conductive finishes, i.e. a PEDOT:PSS Orgacon ICP 1050 dip-coating and a Powersil coating. The purpose is the application especially in the medical field of angiopathy like for bioimpedance measurements during compression therapies. To be able to compare the suitability of the electrodes, various tests have been performed of the coating abrasion resistance, the stability of electrical resistance values, as well as resistance and bioimpedance measurements. Significant differences between the electrodes regarding their resilience and resistance that are visualized in a value-added analysis were found, with one hand-embroidered, one machine-sewn and one commercial electrode showing optimum properties. |
format |
article |
author |
Judith Tabea Meding Khorolsuren Tuvshinbayar Christoph Döpke Ferdinand Tamoue |
author_facet |
Judith Tabea Meding Khorolsuren Tuvshinbayar Christoph Döpke Ferdinand Tamoue |
author_sort |
Judith Tabea Meding |
title |
Textile electrodes for bioimpedance measuring |
title_short |
Textile electrodes for bioimpedance measuring |
title_full |
Textile electrodes for bioimpedance measuring |
title_fullStr |
Textile electrodes for bioimpedance measuring |
title_full_unstemmed |
Textile electrodes for bioimpedance measuring |
title_sort |
textile electrodes for bioimpedance measuring |
publisher |
TU Dresden; Faculty of Mechanical Science and Engineering;Chair of Development and Assembly of Textile Products |
publishDate |
2021 |
url |
https://doaj.org/article/020439e8cf89467693d90610ff714328 |
work_keys_str_mv |
AT judithtabeameding textileelectrodesforbioimpedancemeasuring AT khorolsurentuvshinbayar textileelectrodesforbioimpedancemeasuring AT christophdopke textileelectrodesforbioimpedancemeasuring AT ferdinandtamoue textileelectrodesforbioimpedancemeasuring |
_version_ |
1718441444862066688 |