A material stress test study on occurrence of leakage and material failure of peritoneal dialysis (PD) catheters

Abstract Peritonitis is a common complication of peritoneal dialysis (PD). Our root cause analysis allowed to attribute some cases to leakage of the PD catheter. Accordingly, a clinically based stress test study on potential material damage issues of PD catheters was performed, focusing on material...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Matthias Klingele, Martin Carstens, Lea Baerens, Matthias W. Laschke, Wolfgang Metzger, Danilo Fliser, Clemens M. Meier
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/02043db1f4f74808a69a4d97eabd6adc
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:02043db1f4f74808a69a4d97eabd6adc
record_format dspace
spelling oai:doaj.org-article:02043db1f4f74808a69a4d97eabd6adc2021-12-02T15:43:17ZA material stress test study on occurrence of leakage and material failure of peritoneal dialysis (PD) catheters10.1038/s41598-021-89643-02045-2322https://doaj.org/article/02043db1f4f74808a69a4d97eabd6adc2021-05-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-89643-0https://doaj.org/toc/2045-2322Abstract Peritonitis is a common complication of peritoneal dialysis (PD). Our root cause analysis allowed to attribute some cases to leakage of the PD catheter. Accordingly, a clinically based stress test study on potential material damage issues of PD catheters was performed, focusing on material damage caused by cleaning, de- and attachment procedures during dialysate changes and on the individual storage methods of PD catheters between dialysate changes. PD catheters were exposed to both chemical stress by repeating dialysate-flow and physical stress simulating de- and connecting, fixation, pressure, flexing, folding etc.—simulating standard clinical daily routine of 8–10 years PD catheter usage. Potentially by normal usage caused damages should be then detected by intraluminal pressure, light- and electron microscopy. The multi-step visual control showed no obvious damages on PD catheters nor any leakage or barrier indulgence. Our tests simulating daily routine usage of PD catheters for several years could not detect any material defects under chemical or physical stress. Hence, we presume that most PD catheter damages, as identified cause for peritonitis in some of our patients, may be due to accidental, unnoticed external damage (e.g. through scissors, while changing dressings) or neglecting PD catheter handling specifications.Matthias KlingeleMartin CarstensLea BaerensMatthias W. LaschkeWolfgang MetzgerDanilo FliserClemens M. MeierNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-6 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Matthias Klingele
Martin Carstens
Lea Baerens
Matthias W. Laschke
Wolfgang Metzger
Danilo Fliser
Clemens M. Meier
A material stress test study on occurrence of leakage and material failure of peritoneal dialysis (PD) catheters
description Abstract Peritonitis is a common complication of peritoneal dialysis (PD). Our root cause analysis allowed to attribute some cases to leakage of the PD catheter. Accordingly, a clinically based stress test study on potential material damage issues of PD catheters was performed, focusing on material damage caused by cleaning, de- and attachment procedures during dialysate changes and on the individual storage methods of PD catheters between dialysate changes. PD catheters were exposed to both chemical stress by repeating dialysate-flow and physical stress simulating de- and connecting, fixation, pressure, flexing, folding etc.—simulating standard clinical daily routine of 8–10 years PD catheter usage. Potentially by normal usage caused damages should be then detected by intraluminal pressure, light- and electron microscopy. The multi-step visual control showed no obvious damages on PD catheters nor any leakage or barrier indulgence. Our tests simulating daily routine usage of PD catheters for several years could not detect any material defects under chemical or physical stress. Hence, we presume that most PD catheter damages, as identified cause for peritonitis in some of our patients, may be due to accidental, unnoticed external damage (e.g. through scissors, while changing dressings) or neglecting PD catheter handling specifications.
format article
author Matthias Klingele
Martin Carstens
Lea Baerens
Matthias W. Laschke
Wolfgang Metzger
Danilo Fliser
Clemens M. Meier
author_facet Matthias Klingele
Martin Carstens
Lea Baerens
Matthias W. Laschke
Wolfgang Metzger
Danilo Fliser
Clemens M. Meier
author_sort Matthias Klingele
title A material stress test study on occurrence of leakage and material failure of peritoneal dialysis (PD) catheters
title_short A material stress test study on occurrence of leakage and material failure of peritoneal dialysis (PD) catheters
title_full A material stress test study on occurrence of leakage and material failure of peritoneal dialysis (PD) catheters
title_fullStr A material stress test study on occurrence of leakage and material failure of peritoneal dialysis (PD) catheters
title_full_unstemmed A material stress test study on occurrence of leakage and material failure of peritoneal dialysis (PD) catheters
title_sort material stress test study on occurrence of leakage and material failure of peritoneal dialysis (pd) catheters
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/02043db1f4f74808a69a4d97eabd6adc
work_keys_str_mv AT matthiasklingele amaterialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT martincarstens amaterialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT leabaerens amaterialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT matthiaswlaschke amaterialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT wolfgangmetzger amaterialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT danilofliser amaterialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT clemensmmeier amaterialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT matthiasklingele materialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT martincarstens materialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT leabaerens materialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT matthiaswlaschke materialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT wolfgangmetzger materialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT danilofliser materialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
AT clemensmmeier materialstressteststudyonoccurrenceofleakageandmaterialfailureofperitonealdialysispdcatheters
_version_ 1718385789759389696