METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS

Purpose. To analyze the transient processes in the charge circuit of electric discharge installations with two capacitors, taking into account the change in the initial conditions of such processes (initial voltage on the capacitors and the initial current in the charge circuit) as well as to develo...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: N. I. Suprunovska, M. A. Shcherba
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2018
Materias:
Acceso en línea:https://doaj.org/article/02ab945391b94645afe28b2eec10d8af
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:02ab945391b94645afe28b2eec10d8af
record_format dspace
spelling oai:doaj.org-article:02ab945391b94645afe28b2eec10d8af2021-12-02T16:19:07ZMETHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS10.20998/2074-272X.2018.5.072074-272X2309-3404https://doaj.org/article/02ab945391b94645afe28b2eec10d8af2018-10-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2018.5.07/142859https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. To analyze the transient processes in the charge circuit of electric discharge installations with two capacitors, taking into account the change in the initial conditions of such processes (initial voltage on the capacitors and the initial current in the charge circuit) as well as to develop the method for charge voltage control of such installations using purposeful change of these initial conditions. Methodology. We have applied the concepts of theoretical electrical engineering, the principles of theory of electrical circuits, and mathematical simulation in the software package MathCAD 12. Results. We have obtained analytical expressions and graphical dependencies establishing a quantitative relationship between the value of the maximum charge voltage of an electric discharge installation and the values of the initial voltage on its capacitors and the initial current in the circuit. This allows us to propose the method for the charge voltage control of electric discharge installations with two reservoir capacitors, using a purposeful change in their initial voltages and initial current in the charge circuit. Originality. For the first time, we have found that the charge voltage of the installation can be controlled using two influence mechanisms – either changing the initial current in the charge circuit (by interrupting the transient process of the first capacitor charge at a certain time) or using a nonzero initial voltage on the charged second capacitor. In this case the charge voltage can be varied by 2 times. Practical value. The use of this method makes it possible to obtain discharge pulses of complex shape in the technological load, since the maximum charge voltages of the first capacitor and second one can differ by a factor of 1.5.N. I. SuprunovskaM. A. ShcherbaNational Technical University "Kharkiv Polytechnic Institute"articleelectric discharge installationcapacitor chargecharge voltagetransientsnonzero initial conditionsElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 5, Pp 39-43 (2018)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic electric discharge installation
capacitor charge
charge voltage
transients
nonzero initial conditions
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle electric discharge installation
capacitor charge
charge voltage
transients
nonzero initial conditions
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
N. I. Suprunovska
M. A. Shcherba
METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
description Purpose. To analyze the transient processes in the charge circuit of electric discharge installations with two capacitors, taking into account the change in the initial conditions of such processes (initial voltage on the capacitors and the initial current in the charge circuit) as well as to develop the method for charge voltage control of such installations using purposeful change of these initial conditions. Methodology. We have applied the concepts of theoretical electrical engineering, the principles of theory of electrical circuits, and mathematical simulation in the software package MathCAD 12. Results. We have obtained analytical expressions and graphical dependencies establishing a quantitative relationship between the value of the maximum charge voltage of an electric discharge installation and the values of the initial voltage on its capacitors and the initial current in the circuit. This allows us to propose the method for the charge voltage control of electric discharge installations with two reservoir capacitors, using a purposeful change in their initial voltages and initial current in the charge circuit. Originality. For the first time, we have found that the charge voltage of the installation can be controlled using two influence mechanisms – either changing the initial current in the charge circuit (by interrupting the transient process of the first capacitor charge at a certain time) or using a nonzero initial voltage on the charged second capacitor. In this case the charge voltage can be varied by 2 times. Practical value. The use of this method makes it possible to obtain discharge pulses of complex shape in the technological load, since the maximum charge voltages of the first capacitor and second one can differ by a factor of 1.5.
format article
author N. I. Suprunovska
M. A. Shcherba
author_facet N. I. Suprunovska
M. A. Shcherba
author_sort N. I. Suprunovska
title METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_short METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_full METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_fullStr METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_full_unstemmed METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_sort method for voltage control in charge circuit of electric discharge installations with two capacitors under nonzero initial conditions
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2018
url https://doaj.org/article/02ab945391b94645afe28b2eec10d8af
work_keys_str_mv AT nisuprunovska methodforvoltagecontrolinchargecircuitofelectricdischargeinstallationswithtwocapacitorsundernonzeroinitialconditions
AT mashcherba methodforvoltagecontrolinchargecircuitofelectricdischargeinstallationswithtwocapacitorsundernonzeroinitialconditions
_version_ 1718384152297865216