Implementation of a maternal early warning system during early postpartum. A prospective observational study.

<h4>Objective</h4>To evaluate the implementation of a maternal early warning system (MEWS) for monitoring patients during the first two hours after delivery in a tertiary level hospital.<h4>Methods</h4>Implementation of the criteria between 15 March and 15 September 2018 was...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Cristina Ibáñez-Lorente, Rubén Casans-Francés, Soledad Bellas-Cotán, Luis E Muñoz-Alameda
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/0321f69cd270437b90988b5a5ea2fadd
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:0321f69cd270437b90988b5a5ea2fadd
record_format dspace
spelling oai:doaj.org-article:0321f69cd270437b90988b5a5ea2fadd2021-12-02T20:11:06ZImplementation of a maternal early warning system during early postpartum. A prospective observational study.1932-620310.1371/journal.pone.0252446https://doaj.org/article/0321f69cd270437b90988b5a5ea2fadd2021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0252446https://doaj.org/toc/1932-6203<h4>Objective</h4>To evaluate the implementation of a maternal early warning system (MEWS) for monitoring patients during the first two hours after delivery in a tertiary level hospital.<h4>Methods</h4>Implementation of the criteria between 15 March and 15 September 2018 was evaluated in 1166 patients. The parameters collected were systolic and diastolic blood pressure, heart rate, oxygen saturation, urine output, uterine involution, and bleeding. Out-of-range values of any of these parameters triggered a warning, and an obstetrician was called to examine the patient. The obstetrician then decided whether to call the anesthesiologist. We carried out a sensitivity-specificity study of triggers and a multivariate analysis of the factors involved in developing potentially fatal disorders (PFD), reintervention, critical care admission, and stay.<h4>Results</h4>The MEWS was triggered in 75 patients (6.43%). Leading trigger was altered systolic blood pressure in 32 patients (42.7%), and 11 patients had a PFD. Twenty-eight triggers were false-negatives. Sensitivity and specificity of the system was 0.28 (0.15, 0.45) and 0.94 (0.93, 0.96), respectively. The multivariate analysis showed a correlation between trigger activation and PFD.<h4>Conclusion</h4>Our MEWS presented low sensitivity and high specificity, with a significant number of false-negatives.Cristina Ibáñez-LorenteRubén Casans-FrancésSoledad Bellas-CotánLuis E Muñoz-AlamedaPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 6, p e0252446 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Cristina Ibáñez-Lorente
Rubén Casans-Francés
Soledad Bellas-Cotán
Luis E Muñoz-Alameda
Implementation of a maternal early warning system during early postpartum. A prospective observational study.
description <h4>Objective</h4>To evaluate the implementation of a maternal early warning system (MEWS) for monitoring patients during the first two hours after delivery in a tertiary level hospital.<h4>Methods</h4>Implementation of the criteria between 15 March and 15 September 2018 was evaluated in 1166 patients. The parameters collected were systolic and diastolic blood pressure, heart rate, oxygen saturation, urine output, uterine involution, and bleeding. Out-of-range values of any of these parameters triggered a warning, and an obstetrician was called to examine the patient. The obstetrician then decided whether to call the anesthesiologist. We carried out a sensitivity-specificity study of triggers and a multivariate analysis of the factors involved in developing potentially fatal disorders (PFD), reintervention, critical care admission, and stay.<h4>Results</h4>The MEWS was triggered in 75 patients (6.43%). Leading trigger was altered systolic blood pressure in 32 patients (42.7%), and 11 patients had a PFD. Twenty-eight triggers were false-negatives. Sensitivity and specificity of the system was 0.28 (0.15, 0.45) and 0.94 (0.93, 0.96), respectively. The multivariate analysis showed a correlation between trigger activation and PFD.<h4>Conclusion</h4>Our MEWS presented low sensitivity and high specificity, with a significant number of false-negatives.
format article
author Cristina Ibáñez-Lorente
Rubén Casans-Francés
Soledad Bellas-Cotán
Luis E Muñoz-Alameda
author_facet Cristina Ibáñez-Lorente
Rubén Casans-Francés
Soledad Bellas-Cotán
Luis E Muñoz-Alameda
author_sort Cristina Ibáñez-Lorente
title Implementation of a maternal early warning system during early postpartum. A prospective observational study.
title_short Implementation of a maternal early warning system during early postpartum. A prospective observational study.
title_full Implementation of a maternal early warning system during early postpartum. A prospective observational study.
title_fullStr Implementation of a maternal early warning system during early postpartum. A prospective observational study.
title_full_unstemmed Implementation of a maternal early warning system during early postpartum. A prospective observational study.
title_sort implementation of a maternal early warning system during early postpartum. a prospective observational study.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/0321f69cd270437b90988b5a5ea2fadd
work_keys_str_mv AT cristinaibanezlorente implementationofamaternalearlywarningsystemduringearlypostpartumaprospectiveobservationalstudy
AT rubencasansfrances implementationofamaternalearlywarningsystemduringearlypostpartumaprospectiveobservationalstudy
AT soledadbellascotan implementationofamaternalearlywarningsystemduringearlypostpartumaprospectiveobservationalstudy
AT luisemunozalameda implementationofamaternalearlywarningsystemduringearlypostpartumaprospectiveobservationalstudy
_version_ 1718374923764760576