Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect
The effected of the long transmission line (TL) between the actuator and the hydraulic control valve sometimes essentials. The study is concerned with modeling the TL which carries the oil from the electro-hydraulic servovalve to the actuator. The pressure value inside the TL has been controlled by...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Al-Khwarizmi College of Engineering – University of Baghdad
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/03ab37ab96e84dbb9ca0037b81dd5cec |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:03ab37ab96e84dbb9ca0037b81dd5cec |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:03ab37ab96e84dbb9ca0037b81dd5cec2021-12-02T07:32:14ZPressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect1818-11712312-0789https://doaj.org/article/03ab37ab96e84dbb9ca0037b81dd5cec2013-10-01T00:00:00Zhttp://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/179https://doaj.org/toc/1818-1171https://doaj.org/toc/2312-0789 The effected of the long transmission line (TL) between the actuator and the hydraulic control valve sometimes essentials. The study is concerned with modeling the TL which carries the oil from the electro-hydraulic servovalve to the actuator. The pressure value inside the TL has been controlled by the electro-hydraulic servovalve as a voltage supplied to the servovalve amplifier. The flow rate through the TL has been simulated by using the lumped π element electrical analogy method for laminar flow. The control voltage supplied to servovalve can be achieved by the direct using of the voltage function generator or indirect C++ program connected to the DAP-view program built in the DAP-card data acquisition connected to PC, to control the value of pressure in a selected point in the TL. It has been found that the relation between the voltage value and the output flow rate from the servovalve in most of the path is a linear relation. The MATLAB m-File program is used to create a representation state of the mathematical model to find a good simulation for the experimental open loop control test. Jafar Mehdi HassanYiqin XueMajid Ahmed OleiwiAhmed Fouad MahdiAl-Khwarizmi College of Engineering – University of BaghdadarticleElectro-hydraulic servovalveTwin flapper nozzleTransmission Line effectOpen loop Pressure controlVoltage linearization EquationDAP-view Data AcquisitionChemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 9, Iss 3 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Electro-hydraulic servovalve Twin flapper nozzle Transmission Line effect Open loop Pressure control Voltage linearization Equation DAP-view Data Acquisition Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
Electro-hydraulic servovalve Twin flapper nozzle Transmission Line effect Open loop Pressure control Voltage linearization Equation DAP-view Data Acquisition Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 Jafar Mehdi Hassan Yiqin Xue Majid Ahmed Oleiwi Ahmed Fouad Mahdi Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect |
description |
The effected of the long transmission line (TL) between the actuator and the hydraulic control valve sometimes essentials. The study is concerned with modeling the TL which carries the oil from the electro-hydraulic servovalve to the actuator. The pressure value inside the TL has been controlled by the electro-hydraulic servovalve as a voltage supplied to the servovalve amplifier. The flow rate through the TL has been simulated by using the lumped π element electrical analogy method for laminar flow. The control voltage supplied to servovalve can be achieved by the direct using of the voltage function generator or indirect C++ program connected to the DAP-view program built in the DAP-card data acquisition connected to PC, to control the value of pressure in a selected point in the TL. It has been found that the relation between the voltage value and the output flow rate from the servovalve in most of the path is a linear relation. The MATLAB m-File program is used to create a representation state of the mathematical model to find a good simulation for the experimental open loop control test.
|
format |
article |
author |
Jafar Mehdi Hassan Yiqin Xue Majid Ahmed Oleiwi Ahmed Fouad Mahdi |
author_facet |
Jafar Mehdi Hassan Yiqin Xue Majid Ahmed Oleiwi Ahmed Fouad Mahdi |
author_sort |
Jafar Mehdi Hassan |
title |
Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect |
title_short |
Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect |
title_full |
Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect |
title_fullStr |
Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect |
title_full_unstemmed |
Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect |
title_sort |
pressure control of electro-hydraulic servovalve and transmission line effect |
publisher |
Al-Khwarizmi College of Engineering – University of Baghdad |
publishDate |
2013 |
url |
https://doaj.org/article/03ab37ab96e84dbb9ca0037b81dd5cec |
work_keys_str_mv |
AT jafarmehdihassan pressurecontrolofelectrohydraulicservovalveandtransmissionlineeffect AT yiqinxue pressurecontrolofelectrohydraulicservovalveandtransmissionlineeffect AT majidahmedoleiwi pressurecontrolofelectrohydraulicservovalveandtransmissionlineeffect AT ahmedfouadmahdi pressurecontrolofelectrohydraulicservovalveandtransmissionlineeffect |
_version_ |
1718399318828777472 |