Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect

The effected of the long transmission line (TL) between the actuator and the hydraulic control valve sometimes essentials. The study is concerned with modeling the TL which carries the oil from the electro-hydraulic servovalve to the actuator. The pressure value inside the TL has been controlled by...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jafar Mehdi Hassan, Yiqin Xue, Majid Ahmed Oleiwi, Ahmed Fouad Mahdi
Formato: article
Lenguaje:EN
Publicado: Al-Khwarizmi College of Engineering – University of Baghdad 2013
Materias:
Acceso en línea:https://doaj.org/article/03ab37ab96e84dbb9ca0037b81dd5cec
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:03ab37ab96e84dbb9ca0037b81dd5cec
record_format dspace
spelling oai:doaj.org-article:03ab37ab96e84dbb9ca0037b81dd5cec2021-12-02T07:32:14ZPressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect1818-11712312-0789https://doaj.org/article/03ab37ab96e84dbb9ca0037b81dd5cec2013-10-01T00:00:00Zhttp://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/179https://doaj.org/toc/1818-1171https://doaj.org/toc/2312-0789 The effected of the long transmission line (TL) between the actuator and the hydraulic control valve sometimes essentials. The study is concerned with modeling the TL which carries the oil from the electro-hydraulic servovalve to the actuator. The pressure value inside the TL has been controlled by the electro-hydraulic servovalve as a voltage supplied to the servovalve amplifier. The flow rate through the TL has been simulated by using the lumped π element electrical analogy method for laminar flow. The control voltage supplied to servovalve can be achieved by the direct using of the voltage function generator or indirect C++ program connected to the DAP-view program built in the DAP-card data acquisition connected to PC, to control the value of pressure in a selected point in the TL. It has been found that the relation between the voltage value and the output flow rate from the servovalve in most of the path is a linear relation. The MATLAB m-File program is used to create a representation state of the mathematical model to find a good simulation for the experimental open loop control test. Jafar Mehdi HassanYiqin XueMajid Ahmed OleiwiAhmed Fouad MahdiAl-Khwarizmi College of Engineering – University of BaghdadarticleElectro-hydraulic servovalveTwin flapper nozzleTransmission Line effectOpen loop Pressure controlVoltage linearization EquationDAP-view Data AcquisitionChemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 9, Iss 3 (2013)
institution DOAJ
collection DOAJ
language EN
topic Electro-hydraulic servovalve
Twin flapper nozzle
Transmission Line effect
Open loop Pressure control
Voltage linearization Equation
DAP-view Data Acquisition
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle Electro-hydraulic servovalve
Twin flapper nozzle
Transmission Line effect
Open loop Pressure control
Voltage linearization Equation
DAP-view Data Acquisition
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
Jafar Mehdi Hassan
Yiqin Xue
Majid Ahmed Oleiwi
Ahmed Fouad Mahdi
Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect
description The effected of the long transmission line (TL) between the actuator and the hydraulic control valve sometimes essentials. The study is concerned with modeling the TL which carries the oil from the electro-hydraulic servovalve to the actuator. The pressure value inside the TL has been controlled by the electro-hydraulic servovalve as a voltage supplied to the servovalve amplifier. The flow rate through the TL has been simulated by using the lumped π element electrical analogy method for laminar flow. The control voltage supplied to servovalve can be achieved by the direct using of the voltage function generator or indirect C++ program connected to the DAP-view program built in the DAP-card data acquisition connected to PC, to control the value of pressure in a selected point in the TL. It has been found that the relation between the voltage value and the output flow rate from the servovalve in most of the path is a linear relation. The MATLAB m-File program is used to create a representation state of the mathematical model to find a good simulation for the experimental open loop control test.
format article
author Jafar Mehdi Hassan
Yiqin Xue
Majid Ahmed Oleiwi
Ahmed Fouad Mahdi
author_facet Jafar Mehdi Hassan
Yiqin Xue
Majid Ahmed Oleiwi
Ahmed Fouad Mahdi
author_sort Jafar Mehdi Hassan
title Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect
title_short Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect
title_full Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect
title_fullStr Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect
title_full_unstemmed Pressure Control of Electro-Hydraulic Servovalve and Transmission Line Effect
title_sort pressure control of electro-hydraulic servovalve and transmission line effect
publisher Al-Khwarizmi College of Engineering – University of Baghdad
publishDate 2013
url https://doaj.org/article/03ab37ab96e84dbb9ca0037b81dd5cec
work_keys_str_mv AT jafarmehdihassan pressurecontrolofelectrohydraulicservovalveandtransmissionlineeffect
AT yiqinxue pressurecontrolofelectrohydraulicservovalveandtransmissionlineeffect
AT majidahmedoleiwi pressurecontrolofelectrohydraulicservovalveandtransmissionlineeffect
AT ahmedfouadmahdi pressurecontrolofelectrohydraulicservovalveandtransmissionlineeffect
_version_ 1718399318828777472