A Novel High-Resolution Surface Electrocardiographic Method to Identify and Characterize Myocardial Scar: A Proof-of-Concept Study

Résumé: Contexte: La mise en place de la sonde ventriculaire gauche dans une zone exempte de cicatrice myocardique est un facteur déterminant de la réponse au traitement de resynchronisation cardiaque. Nous avons cherché à développer et à valider une approche électrocardiographique (ECG) simple, co...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Derek S. Chew, MD, MSc, Sharita Manga, MD, MSc, Andrew Roberts, BSc, Glen L. Sumner, MD, MSc, Katherine M. Kavanagh, MD, Andrew G. Howarth, MD, PhD, Carmen Lydell, MD, James A. White, MD, Karen Cowan, RN, Gordon Rowlandson, MEng, Joel Xue, PhD, Derek V. Exner, MD, MPH
Formato: article
Lenguaje:EN
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://doaj.org/article/040f8a1e3b01415a91d372599feff544
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:040f8a1e3b01415a91d372599feff544
record_format dspace
institution DOAJ
collection DOAJ
language EN
topic Diseases of the circulatory (Cardiovascular) system
RC666-701
spellingShingle Diseases of the circulatory (Cardiovascular) system
RC666-701
Derek S. Chew, MD, MSc
Sharita Manga, MD, MSc
Andrew Roberts, BSc
Glen L. Sumner, MD, MSc
Katherine M. Kavanagh, MD
Andrew G. Howarth, MD, PhD
Carmen Lydell, MD
James A. White, MD
Karen Cowan, RN
Gordon Rowlandson, MEng
Joel Xue, PhD
Derek V. Exner, MD, MPH
A Novel High-Resolution Surface Electrocardiographic Method to Identify and Characterize Myocardial Scar: A Proof-of-Concept Study
description Résumé: Contexte: La mise en place de la sonde ventriculaire gauche dans une zone exempte de cicatrice myocardique est un facteur déterminant de la réponse au traitement de resynchronisation cardiaque. Nous avons cherché à développer et à valider une approche électrocardiographique (ECG) simple, concrète et novatrice afin de repérer de manière peropératoire la présence de tissu cicatriciel au ventricule gauche (VG). Nous avons émis l'hypothèse qu'il y aurait une diminution de l'amplitude du rythme de stimulation du ventricule gauche mesurée à la surface de la peau à l'ECG haute résolution (HR) lors de la stimulation de régions du VG présentant du tissu cicatriciel comparativement aux régions exemptes de cicatrices. Il s'agit de ce que nous appelons la méthode EASE (ECG Amplitude Signal Evaluation). Méthodologie: Des patients vus de manière consécutive qui présentaient une dysfonction systolique ischémique du VG et répondaient aux critères standard pour l'implantation de novo d'un dispositif de resynchronisation cardiaque ont été recrutés de manière prospective. Tous ont fait l'objet d'une résonance magnétique cardiaque améliorée par injection d'un produit de contraste avant l'implantation pour évaluer la présence de tissu cicatriciel. L'amplitude moyenne de l'impulsion de stimulation du VG a été échantillonnée sur l'ECG de surface HR réalisé pendant l'intervention, puis comparée aux résultats de la résonance magnétique cardiaque. Résultats: En tout, 38 points de stimulation du VG ont été évalués chez 13 receveurs. Le voltage médian mesuré sur l'ECG de surface HR dans les régions présentant du tissu cicatriciel était réduit de 41 % (intervalle interquartile : 17 % à 63 %), tandis qu'il n'y avait pas de changement mesurable du voltage (intervalle interquartile : 0 à 0 %) dans les régions exemptes de cicatrices par rapport à l'amplitude maximale (test de Wilcoxon, p < 0,0001). Conclusion: La méthode EASE semble avoir une utilité potentielle en tant que nouvel outil peropératoire pour guider la mise en place de la sonde ventriculaire gauche dans les régions exemptes de cicatrices. Il faudra réaliser d'autres travaux pour valider l'utilité de cette méthode dans une cohorte de patients plus importante. Abstract: Background: The placement of the left ventricular (LV) lead in an area free of myocardial scar is an important determinant of cardiac resynchronization therapy response. We sought to develop and validate a simple, practical, and novel electrocardiographic (ECG)-based approach to intraoperatively identify the presence of LV scar. We hypothesized that there would be a reduction in the measured amplitude of the LV pacing stimulus on the skin surface using a high-resolution (HR) ECG when pacing from LV regions with scar compared with regions without scar. We term this the ECG Amplitude Signal Evaluation (EASE) method. Methods: Consecutive patients with ischemic LV systolic dysfunction and standard criteria for de novo cardiac resynchronization therapy implantation were prospectively enrolled. All underwent a preimplant contrast-enhanced cardiac magnetic resonance study to assess for scar. The average amplitude of the LV pacing impulse was sampled on HR surface ECG intraprocedurally and then compared with the cardiac magnetic resonance results. Results: A total of 38 LV pacing sites were assessed among 13 recipients. The median voltage measured on the surface HR ECG in regions with scar was reduced by 41% (interquartile range, 17% to 63%), whereas there was no measurable change in voltage (interquartile range, 0 to 0%) in regions without scar compared with the maximal amplitude (Wilcoxon P < 0.0001). Conclusion: The EASE method appears to be of potential value as a novel intraoperative tool to guide LV lead placement to regions free of scar. Future work is required to validate the utility of this method in a larger patient cohort.
format article
author Derek S. Chew, MD, MSc
Sharita Manga, MD, MSc
Andrew Roberts, BSc
Glen L. Sumner, MD, MSc
Katherine M. Kavanagh, MD
Andrew G. Howarth, MD, PhD
Carmen Lydell, MD
James A. White, MD
Karen Cowan, RN
Gordon Rowlandson, MEng
Joel Xue, PhD
Derek V. Exner, MD, MPH
author_facet Derek S. Chew, MD, MSc
Sharita Manga, MD, MSc
Andrew Roberts, BSc
Glen L. Sumner, MD, MSc
Katherine M. Kavanagh, MD
Andrew G. Howarth, MD, PhD
Carmen Lydell, MD
James A. White, MD
Karen Cowan, RN
Gordon Rowlandson, MEng
Joel Xue, PhD
Derek V. Exner, MD, MPH
author_sort Derek S. Chew, MD, MSc
title A Novel High-Resolution Surface Electrocardiographic Method to Identify and Characterize Myocardial Scar: A Proof-of-Concept Study
title_short A Novel High-Resolution Surface Electrocardiographic Method to Identify and Characterize Myocardial Scar: A Proof-of-Concept Study
title_full A Novel High-Resolution Surface Electrocardiographic Method to Identify and Characterize Myocardial Scar: A Proof-of-Concept Study
title_fullStr A Novel High-Resolution Surface Electrocardiographic Method to Identify and Characterize Myocardial Scar: A Proof-of-Concept Study
title_full_unstemmed A Novel High-Resolution Surface Electrocardiographic Method to Identify and Characterize Myocardial Scar: A Proof-of-Concept Study
title_sort novel high-resolution surface electrocardiographic method to identify and characterize myocardial scar: a proof-of-concept study
publisher Elsevier
publishDate 2021
url https://doaj.org/article/040f8a1e3b01415a91d372599feff544
work_keys_str_mv AT derekschewmdmsc anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT sharitamangamdmsc anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT andrewrobertsbsc anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT glenlsumnermdmsc anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT katherinemkavanaghmd anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT andrewghowarthmdphd anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT carmenlydellmd anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT jamesawhitemd anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT karencowanrn anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT gordonrowlandsonmeng anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT joelxuephd anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT derekvexnermdmph anovelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT derekschewmdmsc novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT sharitamangamdmsc novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT andrewrobertsbsc novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT glenlsumnermdmsc novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT katherinemkavanaghmd novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT andrewghowarthmdphd novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT carmenlydellmd novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT jamesawhitemd novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT karencowanrn novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT gordonrowlandsonmeng novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT joelxuephd novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
AT derekvexnermdmph novelhighresolutionsurfaceelectrocardiographicmethodtoidentifyandcharacterizemyocardialscaraproofofconceptstudy
_version_ 1718409821399547904
spelling oai:doaj.org-article:040f8a1e3b01415a91d372599feff5442021-11-26T04:38:04ZA Novel High-Resolution Surface Electrocardiographic Method to Identify and Characterize Myocardial Scar: A Proof-of-Concept Study2589-790X10.1016/j.cjco.2021.05.010https://doaj.org/article/040f8a1e3b01415a91d372599feff5442021-10-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2589790X21001438https://doaj.org/toc/2589-790XRésumé: Contexte: La mise en place de la sonde ventriculaire gauche dans une zone exempte de cicatrice myocardique est un facteur déterminant de la réponse au traitement de resynchronisation cardiaque. Nous avons cherché à développer et à valider une approche électrocardiographique (ECG) simple, concrète et novatrice afin de repérer de manière peropératoire la présence de tissu cicatriciel au ventricule gauche (VG). Nous avons émis l'hypothèse qu'il y aurait une diminution de l'amplitude du rythme de stimulation du ventricule gauche mesurée à la surface de la peau à l'ECG haute résolution (HR) lors de la stimulation de régions du VG présentant du tissu cicatriciel comparativement aux régions exemptes de cicatrices. Il s'agit de ce que nous appelons la méthode EASE (ECG Amplitude Signal Evaluation). Méthodologie: Des patients vus de manière consécutive qui présentaient une dysfonction systolique ischémique du VG et répondaient aux critères standard pour l'implantation de novo d'un dispositif de resynchronisation cardiaque ont été recrutés de manière prospective. Tous ont fait l'objet d'une résonance magnétique cardiaque améliorée par injection d'un produit de contraste avant l'implantation pour évaluer la présence de tissu cicatriciel. L'amplitude moyenne de l'impulsion de stimulation du VG a été échantillonnée sur l'ECG de surface HR réalisé pendant l'intervention, puis comparée aux résultats de la résonance magnétique cardiaque. Résultats: En tout, 38 points de stimulation du VG ont été évalués chez 13 receveurs. Le voltage médian mesuré sur l'ECG de surface HR dans les régions présentant du tissu cicatriciel était réduit de 41 % (intervalle interquartile : 17 % à 63 %), tandis qu'il n'y avait pas de changement mesurable du voltage (intervalle interquartile : 0 à 0 %) dans les régions exemptes de cicatrices par rapport à l'amplitude maximale (test de Wilcoxon, p < 0,0001). Conclusion: La méthode EASE semble avoir une utilité potentielle en tant que nouvel outil peropératoire pour guider la mise en place de la sonde ventriculaire gauche dans les régions exemptes de cicatrices. Il faudra réaliser d'autres travaux pour valider l'utilité de cette méthode dans une cohorte de patients plus importante. Abstract: Background: The placement of the left ventricular (LV) lead in an area free of myocardial scar is an important determinant of cardiac resynchronization therapy response. We sought to develop and validate a simple, practical, and novel electrocardiographic (ECG)-based approach to intraoperatively identify the presence of LV scar. We hypothesized that there would be a reduction in the measured amplitude of the LV pacing stimulus on the skin surface using a high-resolution (HR) ECG when pacing from LV regions with scar compared with regions without scar. We term this the ECG Amplitude Signal Evaluation (EASE) method. Methods: Consecutive patients with ischemic LV systolic dysfunction and standard criteria for de novo cardiac resynchronization therapy implantation were prospectively enrolled. All underwent a preimplant contrast-enhanced cardiac magnetic resonance study to assess for scar. The average amplitude of the LV pacing impulse was sampled on HR surface ECG intraprocedurally and then compared with the cardiac magnetic resonance results. Results: A total of 38 LV pacing sites were assessed among 13 recipients. The median voltage measured on the surface HR ECG in regions with scar was reduced by 41% (interquartile range, 17% to 63%), whereas there was no measurable change in voltage (interquartile range, 0 to 0%) in regions without scar compared with the maximal amplitude (Wilcoxon P < 0.0001). Conclusion: The EASE method appears to be of potential value as a novel intraoperative tool to guide LV lead placement to regions free of scar. Future work is required to validate the utility of this method in a larger patient cohort.Derek S. Chew, MD, MScSharita Manga, MD, MScAndrew Roberts, BScGlen L. Sumner, MD, MScKatherine M. Kavanagh, MDAndrew G. Howarth, MD, PhDCarmen Lydell, MDJames A. White, MDKaren Cowan, RNGordon Rowlandson, MEngJoel Xue, PhDDerek V. Exner, MD, MPHElsevierarticleDiseases of the circulatory (Cardiovascular) systemRC666-701ENCJC Open, Vol 3, Iss 10, Pp 1207-1213 (2021)