EFFECT OF USING VERSION IMAGE GUIDED SYSTEM ON SURGICALLY INDUCED ASTIGMATISM (SIA) IN PATIENTS UNDERGOING CATARACT SURGERY
Objective: To analyze the effect of use of VERION image guided system on surgically induced astigmatism (SIA) in patients undergoing cataract surgery. Study Design: Randomized controlled trial. Place and Duration of Study: The study was conducted at Armed Forces Institute of Ophthalmology,...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Army Medical College Rawalpindi
2018
|
Materias: | |
Acceso en línea: | https://doaj.org/article/045b8885e8214f919ac44161bf2a24b6 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:045b8885e8214f919ac44161bf2a24b6 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:045b8885e8214f919ac44161bf2a24b62021-11-25T03:18:32ZEFFECT OF USING VERSION IMAGE GUIDED SYSTEM ON SURGICALLY INDUCED ASTIGMATISM (SIA) IN PATIENTS UNDERGOING CATARACT SURGERY0030-96482411-8842https://doaj.org/article/045b8885e8214f919ac44161bf2a24b62018-12-01T00:00:00Zhttps://www.pafmj.org/index.php/PAFMJ/article/view/2535/2081https://doaj.org/toc/0030-9648https://doaj.org/toc/2411-8842Objective: To analyze the effect of use of VERION image guided system on surgically induced astigmatism (SIA) in patients undergoing cataract surgery. Study Design: Randomized controlled trial. Place and Duration of Study: The study was conducted at Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan from Aug 2016 to Dec 2016. Material and Methods: Sixty eyes undergoing cataract surgery with already existing corneal astigmatism of at least 0.5 diopter (D) were included in the study. Cases with already existing ocular pathology or any per operative complication were excluded. Non-probability (purposive) sampling technique was used. Patients were randomly grouped into two groups 1 and 2. Group-1 underwent normal conventional phacoemulsification with no specific predetermined incision site. Group-2 underwent keratometric assessment using VERION image guided system and data was transferred to operating microscope. Steep and flat meridian were displayed on screen and incision were made on steep axis. Pre and 2 week post op keratometric readings were noted on a workup performa for both the groups and compared. All the surgeries were done by the same surgeon. Statistical program for social sciences (SPSS) version 23.0 was used for statistical analysis. Results: Sixty eyes (29 male, 31 female) with mean age of 57.65 ± 7.41 years were studied. Group-1 included 30 eyes with mean age of 56.73 ± 9.16 years. Group-2 also included 30 eyes with mean age of 58.56 ± 5.10 years. Mean pre op astigmatism was 0.93 ± 0.45D and 0.88 ± 0.47 D in group 1 and 2 respectively. Mean........... Asad HabibMuhammad Saim KhanMazhar IshaqArmy Medical College RawalpindiarticleverionphacoemulsificationcataractMedicineRMedicine (General)R5-920ENPakistan Armed Forces Medical Journal, Vol 68, Iss 6, Pp 1533-1537 (2018) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
verion phacoemulsification cataract Medicine R Medicine (General) R5-920 |
spellingShingle |
verion phacoemulsification cataract Medicine R Medicine (General) R5-920 Asad Habib Muhammad Saim Khan Mazhar Ishaq EFFECT OF USING VERSION IMAGE GUIDED SYSTEM ON SURGICALLY INDUCED ASTIGMATISM (SIA) IN PATIENTS UNDERGOING CATARACT SURGERY |
description |
Objective:
To analyze the effect of use of VERION image guided system on surgically induced astigmatism (SIA) in patients undergoing cataract surgery.
Study Design: Randomized controlled trial.
Place and Duration of Study: The study was conducted at Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan from Aug 2016 to Dec 2016.
Material and Methods:
Sixty eyes undergoing cataract surgery with already existing corneal astigmatism of at least 0.5 diopter (D) were included in the study. Cases with already existing ocular pathology or any per operative complication were excluded. Non-probability (purposive) sampling technique was used. Patients were randomly grouped into two groups 1 and 2. Group-1 underwent normal conventional phacoemulsification with no specific predetermined incision site. Group-2 underwent keratometric assessment using VERION image guided system and data was transferred to operating microscope. Steep and flat meridian were displayed on screen and incision were made on steep axis. Pre and 2 week post op keratometric readings were noted on a workup performa for both the groups and compared. All the surgeries were done by the same surgeon. Statistical program for social sciences (SPSS) version 23.0 was used for statistical analysis.
Results:
Sixty eyes (29 male, 31 female) with mean age of 57.65 ± 7.41 years were studied. Group-1 included 30 eyes with mean age of 56.73 ± 9.16 years. Group-2 also included 30 eyes with mean age of 58.56 ± 5.10 years. Mean pre op astigmatism was 0.93 ± 0.45D and 0.88 ± 0.47 D in group 1 and 2 respectively. Mean...........
|
format |
article |
author |
Asad Habib Muhammad Saim Khan Mazhar Ishaq |
author_facet |
Asad Habib Muhammad Saim Khan Mazhar Ishaq |
author_sort |
Asad Habib |
title |
EFFECT OF USING VERSION IMAGE GUIDED SYSTEM ON SURGICALLY INDUCED ASTIGMATISM (SIA) IN PATIENTS UNDERGOING CATARACT SURGERY |
title_short |
EFFECT OF USING VERSION IMAGE GUIDED SYSTEM ON SURGICALLY INDUCED ASTIGMATISM (SIA) IN PATIENTS UNDERGOING CATARACT SURGERY |
title_full |
EFFECT OF USING VERSION IMAGE GUIDED SYSTEM ON SURGICALLY INDUCED ASTIGMATISM (SIA) IN PATIENTS UNDERGOING CATARACT SURGERY |
title_fullStr |
EFFECT OF USING VERSION IMAGE GUIDED SYSTEM ON SURGICALLY INDUCED ASTIGMATISM (SIA) IN PATIENTS UNDERGOING CATARACT SURGERY |
title_full_unstemmed |
EFFECT OF USING VERSION IMAGE GUIDED SYSTEM ON SURGICALLY INDUCED ASTIGMATISM (SIA) IN PATIENTS UNDERGOING CATARACT SURGERY |
title_sort |
effect of using version image guided system on surgically induced astigmatism (sia) in patients undergoing cataract surgery |
publisher |
Army Medical College Rawalpindi |
publishDate |
2018 |
url |
https://doaj.org/article/045b8885e8214f919ac44161bf2a24b6 |
work_keys_str_mv |
AT asadhabib effectofusingversionimageguidedsystemonsurgicallyinducedastigmatismsiainpatientsundergoingcataractsurgery AT muhammadsaimkhan effectofusingversionimageguidedsystemonsurgicallyinducedastigmatismsiainpatientsundergoingcataractsurgery AT mazharishaq effectofusingversionimageguidedsystemonsurgicallyinducedastigmatismsiainpatientsundergoingcataractsurgery |
_version_ |
1718414618137722880 |