Reliability of pelvic floor muscle surface electromyography (sEMG) recordings during synchronous whole body vibration.
The primary aim of the study was to assess intraday and interday reliability of surface electromyography (sEMG) reflex activity of the pelvic floor muscles during synchronous whole-body vibration (S-WBV) of two intensities (30Hz/2mm; 40Hz/4mm) using band-stop filter and high-pass filter signal proce...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/0463fe73ca4e40bca5fc818da697afd2 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:0463fe73ca4e40bca5fc818da697afd2 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:0463fe73ca4e40bca5fc818da697afd22021-12-02T20:11:20ZReliability of pelvic floor muscle surface electromyography (sEMG) recordings during synchronous whole body vibration.1932-620310.1371/journal.pone.0251265https://doaj.org/article/0463fe73ca4e40bca5fc818da697afd22021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0251265https://doaj.org/toc/1932-6203The primary aim of the study was to assess intraday and interday reliability of surface electromyography (sEMG) reflex activity of the pelvic floor muscles during synchronous whole-body vibration (S-WBV) of two intensities (30Hz/2mm; 40Hz/4mm) using band-stop filter and high-pass filter signal processing. The secondary aim of the study was to assess intraday and interday (test-retest) reliability of sEMG obtained from maximal voluntary contraction (MVC) test. We evaluated the intraday reliability of sEMG recordings obtained during sessions 1 and 2 performed on the same day. The sessions consisting of maximal voluntary pelvic floor muscle contraction and synchronous vibration sets with 1-hour rest in-between sessions 1 and 2 in healthy nulliparous women. The next intraday reliability was evaluated between the results of sessions 3 and 4 performed on the same day but followed at an interval of 4 weeks. to include the entire menstrual cycle. The interday reliability was determined based on the results of sessions 1 and 3 using the intraclass correlation coefficient (ICC 3,3). The intraday ICCs for band-stop filtered mean and median sEMG frequency and mean normalized sEMGRMS amplitude of the 30Hz/2mm (ICC = 0.89-0.99) and 40Hz/4mm vibration (ICC = 0.95-0.99) indicated substantial reproducibility. The intraday reliability of high-pass filter at 100-450Hz for these parameters was also substantial (30Hz/2mm ICC of 0.92 to 0.98; 40Hz/4mm ICC of 0.88 to 0.98). The interday reliability (session 1 vs. session 3) of the mean normalized sEMGRMS amplitude for band-stop filtered means of 40 Hz/4mm and 30Hz/2mm vibration recordings was substantial (ICC = 0.82 and 0.93). However, ICCs of the mean and median frequency were indicative of fair reliability (ICC of 0.43 to 0.59). The interday reliability of mean normalized sEMGRMS amplitude for high-pass filter at 100-450Hz was substantial (30Hz/2mm ICC of 0.90; 40Hz/4mm ICC of 0.73) for the 30Hz/2mm S-WBV and moderate (ICC = 0.73) for the 40/4mm S-WBV. The ICCs for mean and median sEMG frequency ICCs indicated slight to fair reproducibility (ICC of 0.16 to 0.56). The intraday reliability of the strongest MVC contraction and average MVC turned out substantial (ICC = 0.91-0.98). The interday reliability coefficients of the strongest MVC contraction and average MVCs were 0.91 and 0.82, respectively. Concluded, the intraday reliability proved satisfactory for all variables; however, the interday comparison showed sufficient ICC levels only for the mean amplitude. We therefore recommend this parameter should be used when analyzing PFM sEMG recorded during vibration. ICCs of the mean and median frequency for both signal processing methods were indicative of insufficient reliability and did not reach the threshold for usefulness. Our study showed similar reliability of PFM sEMG during S-WBV in case of the two filtering methods used.Daria ChmielewskaGrzegorz SobotaPaweł DolibogPatrycja DolibogAgnieszka Opala-BerdzikPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 5, p e0251265 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Daria Chmielewska Grzegorz Sobota Paweł Dolibog Patrycja Dolibog Agnieszka Opala-Berdzik Reliability of pelvic floor muscle surface electromyography (sEMG) recordings during synchronous whole body vibration. |
description |
The primary aim of the study was to assess intraday and interday reliability of surface electromyography (sEMG) reflex activity of the pelvic floor muscles during synchronous whole-body vibration (S-WBV) of two intensities (30Hz/2mm; 40Hz/4mm) using band-stop filter and high-pass filter signal processing. The secondary aim of the study was to assess intraday and interday (test-retest) reliability of sEMG obtained from maximal voluntary contraction (MVC) test. We evaluated the intraday reliability of sEMG recordings obtained during sessions 1 and 2 performed on the same day. The sessions consisting of maximal voluntary pelvic floor muscle contraction and synchronous vibration sets with 1-hour rest in-between sessions 1 and 2 in healthy nulliparous women. The next intraday reliability was evaluated between the results of sessions 3 and 4 performed on the same day but followed at an interval of 4 weeks. to include the entire menstrual cycle. The interday reliability was determined based on the results of sessions 1 and 3 using the intraclass correlation coefficient (ICC 3,3). The intraday ICCs for band-stop filtered mean and median sEMG frequency and mean normalized sEMGRMS amplitude of the 30Hz/2mm (ICC = 0.89-0.99) and 40Hz/4mm vibration (ICC = 0.95-0.99) indicated substantial reproducibility. The intraday reliability of high-pass filter at 100-450Hz for these parameters was also substantial (30Hz/2mm ICC of 0.92 to 0.98; 40Hz/4mm ICC of 0.88 to 0.98). The interday reliability (session 1 vs. session 3) of the mean normalized sEMGRMS amplitude for band-stop filtered means of 40 Hz/4mm and 30Hz/2mm vibration recordings was substantial (ICC = 0.82 and 0.93). However, ICCs of the mean and median frequency were indicative of fair reliability (ICC of 0.43 to 0.59). The interday reliability of mean normalized sEMGRMS amplitude for high-pass filter at 100-450Hz was substantial (30Hz/2mm ICC of 0.90; 40Hz/4mm ICC of 0.73) for the 30Hz/2mm S-WBV and moderate (ICC = 0.73) for the 40/4mm S-WBV. The ICCs for mean and median sEMG frequency ICCs indicated slight to fair reproducibility (ICC of 0.16 to 0.56). The intraday reliability of the strongest MVC contraction and average MVC turned out substantial (ICC = 0.91-0.98). The interday reliability coefficients of the strongest MVC contraction and average MVCs were 0.91 and 0.82, respectively. Concluded, the intraday reliability proved satisfactory for all variables; however, the interday comparison showed sufficient ICC levels only for the mean amplitude. We therefore recommend this parameter should be used when analyzing PFM sEMG recorded during vibration. ICCs of the mean and median frequency for both signal processing methods were indicative of insufficient reliability and did not reach the threshold for usefulness. Our study showed similar reliability of PFM sEMG during S-WBV in case of the two filtering methods used. |
format |
article |
author |
Daria Chmielewska Grzegorz Sobota Paweł Dolibog Patrycja Dolibog Agnieszka Opala-Berdzik |
author_facet |
Daria Chmielewska Grzegorz Sobota Paweł Dolibog Patrycja Dolibog Agnieszka Opala-Berdzik |
author_sort |
Daria Chmielewska |
title |
Reliability of pelvic floor muscle surface electromyography (sEMG) recordings during synchronous whole body vibration. |
title_short |
Reliability of pelvic floor muscle surface electromyography (sEMG) recordings during synchronous whole body vibration. |
title_full |
Reliability of pelvic floor muscle surface electromyography (sEMG) recordings during synchronous whole body vibration. |
title_fullStr |
Reliability of pelvic floor muscle surface electromyography (sEMG) recordings during synchronous whole body vibration. |
title_full_unstemmed |
Reliability of pelvic floor muscle surface electromyography (sEMG) recordings during synchronous whole body vibration. |
title_sort |
reliability of pelvic floor muscle surface electromyography (semg) recordings during synchronous whole body vibration. |
publisher |
Public Library of Science (PLoS) |
publishDate |
2021 |
url |
https://doaj.org/article/0463fe73ca4e40bca5fc818da697afd2 |
work_keys_str_mv |
AT dariachmielewska reliabilityofpelvicfloormusclesurfaceelectromyographysemgrecordingsduringsynchronouswholebodyvibration AT grzegorzsobota reliabilityofpelvicfloormusclesurfaceelectromyographysemgrecordingsduringsynchronouswholebodyvibration AT pawełdolibog reliabilityofpelvicfloormusclesurfaceelectromyographysemgrecordingsduringsynchronouswholebodyvibration AT patrycjadolibog reliabilityofpelvicfloormusclesurfaceelectromyographysemgrecordingsduringsynchronouswholebodyvibration AT agnieszkaopalaberdzik reliabilityofpelvicfloormusclesurfaceelectromyographysemgrecordingsduringsynchronouswholebodyvibration |
_version_ |
1718374864480370688 |