A Chemically Patterned Microfluidic Paper-based Analytical Device (C-µPAD) for Point-of-Care Diagnostics

Abstract A chemically patterned microfluidic paper-based analytical device (C-µPAD) is developed to create fluidic networks by forming hydrophobic barriers using chemical vapor deposition (CVD) of trichlorosilane (TCS) on a chromatography paper. By controlling temperature, pattern size, and CVD dura...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Trinh Lam, Jasmine P. Devadhasan, Ryan Howse, Jungkyu Kim
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/05409e1468c5498b9a2b6ff35a3c2a3d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:05409e1468c5498b9a2b6ff35a3c2a3d
record_format dspace
spelling oai:doaj.org-article:05409e1468c5498b9a2b6ff35a3c2a3d2021-12-02T12:32:38ZA Chemically Patterned Microfluidic Paper-based Analytical Device (C-µPAD) for Point-of-Care Diagnostics10.1038/s41598-017-01343-w2045-2322https://doaj.org/article/05409e1468c5498b9a2b6ff35a3c2a3d2017-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-01343-whttps://doaj.org/toc/2045-2322Abstract A chemically patterned microfluidic paper-based analytical device (C-µPAD) is developed to create fluidic networks by forming hydrophobic barriers using chemical vapor deposition (CVD) of trichlorosilane (TCS) on a chromatography paper. By controlling temperature, pattern size, and CVD duration, optimal conditions were determined by characterizing hydrophobicity, spreading patterns, and flow behavior on various sized fluidic patterns. With these optimal conditions, we demonstrated glucose assay, immunoassay, and heavy metal detection on well-spot C-µPAD and lateral flow C-µPAD. For these assays, standard curves showing correlation between target concentration and gray intensity were obtained to determine a limit of detection (LOD) of each assay. For the glucose assays on both well-spot C-µPAD and lateral flow C-µPAD, we achieved LOD of 13 mg/dL, which is equivalent to that of a commercial glucose sensor. Similar results were obtained from tumor necrosis factor alpha (TNFα) detection with 3 ng/mL of LOD. For Ni detection, a colorimetric agent was immobilized to obtain a stationary and uniform reaction by using thermal condensation coupling method. During the immobilization, we successfully functionalized amine for coupling the colorimetric agent on the C-µPAD and detected as low as 150 μg/L of Ni. These C-µPADs enable simple, rapid, and cost-effective bioassays and environmental monitoring, which provide practically relevant LODs with high expandability and adaptability.Trinh LamJasmine P. DevadhasanRyan HowseJungkyu KimNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-10 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Trinh Lam
Jasmine P. Devadhasan
Ryan Howse
Jungkyu Kim
A Chemically Patterned Microfluidic Paper-based Analytical Device (C-µPAD) for Point-of-Care Diagnostics
description Abstract A chemically patterned microfluidic paper-based analytical device (C-µPAD) is developed to create fluidic networks by forming hydrophobic barriers using chemical vapor deposition (CVD) of trichlorosilane (TCS) on a chromatography paper. By controlling temperature, pattern size, and CVD duration, optimal conditions were determined by characterizing hydrophobicity, spreading patterns, and flow behavior on various sized fluidic patterns. With these optimal conditions, we demonstrated glucose assay, immunoassay, and heavy metal detection on well-spot C-µPAD and lateral flow C-µPAD. For these assays, standard curves showing correlation between target concentration and gray intensity were obtained to determine a limit of detection (LOD) of each assay. For the glucose assays on both well-spot C-µPAD and lateral flow C-µPAD, we achieved LOD of 13 mg/dL, which is equivalent to that of a commercial glucose sensor. Similar results were obtained from tumor necrosis factor alpha (TNFα) detection with 3 ng/mL of LOD. For Ni detection, a colorimetric agent was immobilized to obtain a stationary and uniform reaction by using thermal condensation coupling method. During the immobilization, we successfully functionalized amine for coupling the colorimetric agent on the C-µPAD and detected as low as 150 μg/L of Ni. These C-µPADs enable simple, rapid, and cost-effective bioassays and environmental monitoring, which provide practically relevant LODs with high expandability and adaptability.
format article
author Trinh Lam
Jasmine P. Devadhasan
Ryan Howse
Jungkyu Kim
author_facet Trinh Lam
Jasmine P. Devadhasan
Ryan Howse
Jungkyu Kim
author_sort Trinh Lam
title A Chemically Patterned Microfluidic Paper-based Analytical Device (C-µPAD) for Point-of-Care Diagnostics
title_short A Chemically Patterned Microfluidic Paper-based Analytical Device (C-µPAD) for Point-of-Care Diagnostics
title_full A Chemically Patterned Microfluidic Paper-based Analytical Device (C-µPAD) for Point-of-Care Diagnostics
title_fullStr A Chemically Patterned Microfluidic Paper-based Analytical Device (C-µPAD) for Point-of-Care Diagnostics
title_full_unstemmed A Chemically Patterned Microfluidic Paper-based Analytical Device (C-µPAD) for Point-of-Care Diagnostics
title_sort chemically patterned microfluidic paper-based analytical device (c-µpad) for point-of-care diagnostics
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/05409e1468c5498b9a2b6ff35a3c2a3d
work_keys_str_mv AT trinhlam achemicallypatternedmicrofluidicpaperbasedanalyticaldevicecμpadforpointofcarediagnostics
AT jasminepdevadhasan achemicallypatternedmicrofluidicpaperbasedanalyticaldevicecμpadforpointofcarediagnostics
AT ryanhowse achemicallypatternedmicrofluidicpaperbasedanalyticaldevicecμpadforpointofcarediagnostics
AT jungkyukim achemicallypatternedmicrofluidicpaperbasedanalyticaldevicecμpadforpointofcarediagnostics
AT trinhlam chemicallypatternedmicrofluidicpaperbasedanalyticaldevicecμpadforpointofcarediagnostics
AT jasminepdevadhasan chemicallypatternedmicrofluidicpaperbasedanalyticaldevicecμpadforpointofcarediagnostics
AT ryanhowse chemicallypatternedmicrofluidicpaperbasedanalyticaldevicecμpadforpointofcarediagnostics
AT jungkyukim chemicallypatternedmicrofluidicpaperbasedanalyticaldevicecμpadforpointofcarediagnostics
_version_ 1718393958016483328