Analysis of the impact of Combined Cycle in the energy transition

The energy transition of the Italian electrical sector is balancing the objective of renewable energy sources generation increase and the need of maintaining a proper electrical system stability. In the next years, the phase-out of the coal will be covered by an increase of the renewable energy sour...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Vannoni Alberto, Belotti Daria, Sorce Alessandro, Massardo Aristide Fausto
Formato: article
Lenguaje:EN
FR
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/05f2838969af4caba287462e6a73ea94
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:05f2838969af4caba287462e6a73ea94
record_format dspace
spelling oai:doaj.org-article:05f2838969af4caba287462e6a73ea942021-11-08T15:18:50ZAnalysis of the impact of Combined Cycle in the energy transition2267-124210.1051/e3sconf/202131201001https://doaj.org/article/05f2838969af4caba287462e6a73ea942021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/88/e3sconf_ati2021_01001.pdfhttps://doaj.org/toc/2267-1242The energy transition of the Italian electrical sector is balancing the objective of renewable energy sources generation increase and the need of maintaining a proper electrical system stability. In the next years, the phase-out of the coal will be covered by an increase of the renewable energy source exploitation supported by natural gas and biogas backup production. In this context, the production of electricity from natural gas, mainly produced by Combined Cycles Gas Turbines (CCGT) plants, that in 2019 covered 48.2% of the Italian electricity generation, will maintain its relevance at national level, even if a more flexible operating profile is envisaged. The use of Combined Cycles as backup power plants will further increase the frequency of transient operating conditions (i.e. start and stop), reducing their load factor and increasing the weight of the emissions related to transient operation with respect to those related to normal operation. In this paper, the operating profile of 45 Italian power-oriented CCGTs are analyzed showing the similarities of management in the different market zones and identifying the main operating patterns. Then a statistical analysis of the emission during normal and transient operation is performed basing on the public available yearly emission statement and highlighting the effect of the CO catalyzer during the transient. Finally, the yearly environmental impact of the flexible operation was assessed and compared to the yearly emission considered during the Environmental Impact Assessment, the Italian VIA (Valutazione di Impatto Ambientale).Vannoni AlbertoBelotti DariaSorce AlessandroMassardo Aristide FaustoEDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 312, p 01001 (2021)
institution DOAJ
collection DOAJ
language EN
FR
topic Environmental sciences
GE1-350
spellingShingle Environmental sciences
GE1-350
Vannoni Alberto
Belotti Daria
Sorce Alessandro
Massardo Aristide Fausto
Analysis of the impact of Combined Cycle in the energy transition
description The energy transition of the Italian electrical sector is balancing the objective of renewable energy sources generation increase and the need of maintaining a proper electrical system stability. In the next years, the phase-out of the coal will be covered by an increase of the renewable energy source exploitation supported by natural gas and biogas backup production. In this context, the production of electricity from natural gas, mainly produced by Combined Cycles Gas Turbines (CCGT) plants, that in 2019 covered 48.2% of the Italian electricity generation, will maintain its relevance at national level, even if a more flexible operating profile is envisaged. The use of Combined Cycles as backup power plants will further increase the frequency of transient operating conditions (i.e. start and stop), reducing their load factor and increasing the weight of the emissions related to transient operation with respect to those related to normal operation. In this paper, the operating profile of 45 Italian power-oriented CCGTs are analyzed showing the similarities of management in the different market zones and identifying the main operating patterns. Then a statistical analysis of the emission during normal and transient operation is performed basing on the public available yearly emission statement and highlighting the effect of the CO catalyzer during the transient. Finally, the yearly environmental impact of the flexible operation was assessed and compared to the yearly emission considered during the Environmental Impact Assessment, the Italian VIA (Valutazione di Impatto Ambientale).
format article
author Vannoni Alberto
Belotti Daria
Sorce Alessandro
Massardo Aristide Fausto
author_facet Vannoni Alberto
Belotti Daria
Sorce Alessandro
Massardo Aristide Fausto
author_sort Vannoni Alberto
title Analysis of the impact of Combined Cycle in the energy transition
title_short Analysis of the impact of Combined Cycle in the energy transition
title_full Analysis of the impact of Combined Cycle in the energy transition
title_fullStr Analysis of the impact of Combined Cycle in the energy transition
title_full_unstemmed Analysis of the impact of Combined Cycle in the energy transition
title_sort analysis of the impact of combined cycle in the energy transition
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/05f2838969af4caba287462e6a73ea94
work_keys_str_mv AT vannonialberto analysisoftheimpactofcombinedcycleintheenergytransition
AT belottidaria analysisoftheimpactofcombinedcycleintheenergytransition
AT sorcealessandro analysisoftheimpactofcombinedcycleintheenergytransition
AT massardoaristidefausto analysisoftheimpactofcombinedcycleintheenergytransition
_version_ 1718442013126295552