Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients
Sarwat Salim, Haiming Du, Sumalee Boonyaleephan, Jim WanUniversity of Tennessee Health Science Center, Memphis, TN, USAPurpose: To compare the surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients.Design: Retrospective comparative case series.Me...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2012
|
Materias: | |
Acceso en línea: | https://doaj.org/article/077a50a6298545f599d6f63831a9f51d |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:077a50a6298545f599d6f63831a9f51d |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:077a50a6298545f599d6f63831a9f51d2021-12-02T08:21:05ZSurgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients1177-54671177-5483https://doaj.org/article/077a50a6298545f599d6f63831a9f51d2012-06-01T00:00:00Zhttp://www.dovepress.com/surgical-outcomes-of-the-ex-press-glaucoma-filtration-device-in-africa-a10197https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Sarwat Salim, Haiming Du, Sumalee Boonyaleephan, Jim WanUniversity of Tennessee Health Science Center, Memphis, TN, USAPurpose: To compare the surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients.Design: Retrospective comparative case series.Methods: This was a comparative case series of 36 eyes of 36 African Americans and 43 eyes of 43 whites that underwent placement of the Ex-PRESS glaucoma filtration device under a partial-thickness scleral flap for uncontrolled glaucoma. All eyes received intraoperative mitomycin C. The primary outcome measures were intraocular pressure (IOP), number of postoperative glaucoma medications, and surgical success. Surgical success was defined as IOP between 5 and 18 mm Hg, with or without glaucoma medications, without further glaucoma surgery, or loss of light perception vision. Results: Average follow-up was 31.9 ± 9.8 (range, 14.6–47) months for African Americans and 30.7 ± 8.6 (range, 14.3–47) months for whites. At 33 months, surgical success was 80.0% in the African American group and 83.3% in the white group (P = 1.00). Reasons for surgical failure included increased IOP (3 eyes, 3.8%), persistent hypotony with maculopathy (1 eye, 1.3%), and further surgery (4 eyes, 5.06%). Compared with preoperative values, the mean postoperative IOP and number of glaucoma medications were significantly reduced in both groups, and no statistical difference was observed between the two groups at 33 months. Postoperative complications were similar in the two groups.Conclusions: Similar surgical outcomes were observed in African American and white glaucoma patients after implantation of the Ex-PRESS glaucoma filtration device. This latest modification of glaucoma filtration surgery may be a better surgical option for African Americans given its potential advantages of no tissue removal, predictable outcomes related to consistent lumen size and controlled flow, fewer postoperative complications, and overall reduced inflammation. Keywords: glaucoma, trabeculectomy, Ex-PRESS glaucoma filtration device, antimetabolites, African American, WhiteSalim SDu HBoonyaleephan SWan JDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2012, Iss default, Pp 955-962 (2012) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Salim S Du H Boonyaleephan S Wan J Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients |
description |
Sarwat Salim, Haiming Du, Sumalee Boonyaleephan, Jim WanUniversity of Tennessee Health Science Center, Memphis, TN, USAPurpose: To compare the surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients.Design: Retrospective comparative case series.Methods: This was a comparative case series of 36 eyes of 36 African Americans and 43 eyes of 43 whites that underwent placement of the Ex-PRESS glaucoma filtration device under a partial-thickness scleral flap for uncontrolled glaucoma. All eyes received intraoperative mitomycin C. The primary outcome measures were intraocular pressure (IOP), number of postoperative glaucoma medications, and surgical success. Surgical success was defined as IOP between 5 and 18 mm Hg, with or without glaucoma medications, without further glaucoma surgery, or loss of light perception vision. Results: Average follow-up was 31.9 ± 9.8 (range, 14.6–47) months for African Americans and 30.7 ± 8.6 (range, 14.3–47) months for whites. At 33 months, surgical success was 80.0% in the African American group and 83.3% in the white group (P = 1.00). Reasons for surgical failure included increased IOP (3 eyes, 3.8%), persistent hypotony with maculopathy (1 eye, 1.3%), and further surgery (4 eyes, 5.06%). Compared with preoperative values, the mean postoperative IOP and number of glaucoma medications were significantly reduced in both groups, and no statistical difference was observed between the two groups at 33 months. Postoperative complications were similar in the two groups.Conclusions: Similar surgical outcomes were observed in African American and white glaucoma patients after implantation of the Ex-PRESS glaucoma filtration device. This latest modification of glaucoma filtration surgery may be a better surgical option for African Americans given its potential advantages of no tissue removal, predictable outcomes related to consistent lumen size and controlled flow, fewer postoperative complications, and overall reduced inflammation. Keywords: glaucoma, trabeculectomy, Ex-PRESS glaucoma filtration device, antimetabolites, African American, White |
format |
article |
author |
Salim S Du H Boonyaleephan S Wan J |
author_facet |
Salim S Du H Boonyaleephan S Wan J |
author_sort |
Salim S |
title |
Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients |
title_short |
Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients |
title_full |
Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients |
title_fullStr |
Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients |
title_full_unstemmed |
Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients |
title_sort |
surgical outcomes of the ex-press glaucoma filtration device in african american and white glaucoma patients |
publisher |
Dove Medical Press |
publishDate |
2012 |
url |
https://doaj.org/article/077a50a6298545f599d6f63831a9f51d |
work_keys_str_mv |
AT salims surgicaloutcomesoftheexpressglaucomafiltrationdeviceinafricanamericanandwhiteglaucomapatients AT duh surgicaloutcomesoftheexpressglaucomafiltrationdeviceinafricanamericanandwhiteglaucomapatients AT boonyaleephans surgicaloutcomesoftheexpressglaucomafiltrationdeviceinafricanamericanandwhiteglaucomapatients AT wanj surgicaloutcomesoftheexpressglaucomafiltrationdeviceinafricanamericanandwhiteglaucomapatients |
_version_ |
1718398523414675456 |