Noise performance of textile‐based dry ECG recording electrodes

Abstract This study reports attempts to characterise the noise properties of un‐gelled, textile‐based electrodes intended for use in ECG recording in wearable garments. Measurements were made using very low noise operational amplifiers and with mains power supply interference eliminated from the rec...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Soumyajyoti Maji, Martin J. Burke
Formato: article
Lenguaje:EN
Publicado: Wiley 2021
Materias:
Acceso en línea:https://doaj.org/article/07fc01a4e09c4425bbca925506ba4649
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:07fc01a4e09c4425bbca925506ba4649
record_format dspace
spelling oai:doaj.org-article:07fc01a4e09c4425bbca925506ba46492021-11-16T10:15:44ZNoise performance of textile‐based dry ECG recording electrodes1350-911X0013-519410.1049/ell2.12063https://doaj.org/article/07fc01a4e09c4425bbca925506ba46492021-01-01T00:00:00Zhttps://doi.org/10.1049/ell2.12063https://doaj.org/toc/0013-5194https://doaj.org/toc/1350-911XAbstract This study reports attempts to characterise the noise properties of un‐gelled, textile‐based electrodes intended for use in ECG recording in wearable garments. Measurements were made using very low noise operational amplifiers and with mains power supply interference eliminated from the recorded signals so that they reflected only genuine noise. Measurements were carried out on four conductive fabric electrodes, one conductive rubber electrode and a standard self‐adhesive, gelled electrode on three male and three female subjects. Curves of the form y = K/f + C were fitted to the recorded noise spectral density functions. Coefficients obtained for the white noise spectral density ranged from 1.1 to 5.6 nV/√Hz and for the flicker (1/f) noise spectral density ranged from 8 to 80 nV√Hz.Soumyajyoti MajiMartin J. BurkeWileyarticleElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENElectronics Letters, Vol 57, Iss 2, Pp 45-48 (2021)
institution DOAJ
collection DOAJ
language EN
topic Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Soumyajyoti Maji
Martin J. Burke
Noise performance of textile‐based dry ECG recording electrodes
description Abstract This study reports attempts to characterise the noise properties of un‐gelled, textile‐based electrodes intended for use in ECG recording in wearable garments. Measurements were made using very low noise operational amplifiers and with mains power supply interference eliminated from the recorded signals so that they reflected only genuine noise. Measurements were carried out on four conductive fabric electrodes, one conductive rubber electrode and a standard self‐adhesive, gelled electrode on three male and three female subjects. Curves of the form y = K/f + C were fitted to the recorded noise spectral density functions. Coefficients obtained for the white noise spectral density ranged from 1.1 to 5.6 nV/√Hz and for the flicker (1/f) noise spectral density ranged from 8 to 80 nV√Hz.
format article
author Soumyajyoti Maji
Martin J. Burke
author_facet Soumyajyoti Maji
Martin J. Burke
author_sort Soumyajyoti Maji
title Noise performance of textile‐based dry ECG recording electrodes
title_short Noise performance of textile‐based dry ECG recording electrodes
title_full Noise performance of textile‐based dry ECG recording electrodes
title_fullStr Noise performance of textile‐based dry ECG recording electrodes
title_full_unstemmed Noise performance of textile‐based dry ECG recording electrodes
title_sort noise performance of textile‐based dry ecg recording electrodes
publisher Wiley
publishDate 2021
url https://doaj.org/article/07fc01a4e09c4425bbca925506ba4649
work_keys_str_mv AT soumyajyotimaji noiseperformanceoftextilebaseddryecgrecordingelectrodes
AT martinjburke noiseperformanceoftextilebaseddryecgrecordingelectrodes
_version_ 1718426525551820800