Invariants of energy characteristics of two-ports with variable loads
Energy characteristics as the load power and efficiency via the load resistance are the well-known two-valued cubic curves. The consideration of these quadratic fractional expressions as geometric projective transformations makes it possible to introduce the cross ratio of four points in limited sin...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
D.Ghitu Institute of Electronic Engineering and Nanotechnologies
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/082662e8e79942f983ea800e8e2fc84f |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:082662e8e79942f983ea800e8e2fc84f |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:082662e8e79942f983ea800e8e2fc84f2021-11-21T11:55:59ZInvariants of energy characteristics of two-ports with variable loads537.3+621.3:620.92537-63651810-648Xhttps://doaj.org/article/082662e8e79942f983ea800e8e2fc84f2019-12-01T00:00:00Zhttps://mjps.nanotech.md/archive/2019/article/98982https://doaj.org/toc/1810-648Xhttps://doaj.org/toc/2537-6365Energy characteristics as the load power and efficiency via the load resistance are the well-known two-valued cubic curves. The consideration of these quadratic fractional expressions as geometric projective transformations makes it possible to introduce the cross ratio of four points in limited single-valued working areas. The cross ratio is accepted as the regime parameter in a relative form, which is invariant to a type of the actual regime parameters and circuit sections. The form of expressions for the actual parameter changes depends on the actual regime type. Changes in regime parameters are proved; direct formulas of recalculation are proposed.Penin, AlexandruSidorenko, AnatolieD.Ghitu Institute of Electronic Engineering and NanotechnologiesarticlePhysicsQC1-999ElectronicsTK7800-8360ENMoldavian Journal of the Physical Sciences, Vol 18, Iss 1-4, Pp 97-109 (2019) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Physics QC1-999 Electronics TK7800-8360 |
spellingShingle |
Physics QC1-999 Electronics TK7800-8360 Penin, Alexandru Sidorenko, Anatolie Invariants of energy characteristics of two-ports with variable loads |
description |
Energy characteristics as the load power and efficiency via the load resistance are the well-known two-valued cubic curves. The consideration of these quadratic fractional expressions as geometric projective transformations makes it possible to introduce the cross ratio of four points in limited single-valued working areas. The cross ratio is accepted as the regime parameter in a relative form, which is invariant to a type of the actual regime parameters and circuit sections. The form of expressions for the actual parameter changes depends on the actual regime type. Changes in regime parameters are proved; direct formulas of recalculation are proposed. |
format |
article |
author |
Penin, Alexandru Sidorenko, Anatolie |
author_facet |
Penin, Alexandru Sidorenko, Anatolie |
author_sort |
Penin, Alexandru |
title |
Invariants of energy characteristics of two-ports with variable loads |
title_short |
Invariants of energy characteristics of two-ports with variable loads |
title_full |
Invariants of energy characteristics of two-ports with variable loads |
title_fullStr |
Invariants of energy characteristics of two-ports with variable loads |
title_full_unstemmed |
Invariants of energy characteristics of two-ports with variable loads |
title_sort |
invariants of energy characteristics of two-ports with variable loads |
publisher |
D.Ghitu Institute of Electronic Engineering and Nanotechnologies |
publishDate |
2019 |
url |
https://doaj.org/article/082662e8e79942f983ea800e8e2fc84f |
work_keys_str_mv |
AT peninalexandru invariantsofenergycharacteristicsoftwoportswithvariableloads AT sidorenkoanatolie invariantsofenergycharacteristicsoftwoportswithvariableloads |
_version_ |
1718419344741892096 |