Non-Descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis

Teruumi Minezaki, Takaaki Hattori, Hayate Nakagawa, Shigeto Kumakura, Hiroshi GotoDepartment of Ophthalmology, Tokyo Medical University, Shinjukuku, Tokyo, JapanPurpose: To report a case of bullous keratopathy secondary to iridoschisis treated by non-Descemet's stripping automated endothelia...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Minezaki T, Hattori T, Nakagawa H, Kumakura S, Goto H
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://doaj.org/article/08ee9ed1711d45e89fcb16bc87dc6812
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:08ee9ed1711d45e89fcb16bc87dc6812
record_format dspace
spelling oai:doaj.org-article:08ee9ed1711d45e89fcb16bc87dc68122021-12-02T01:13:18ZNon-Descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis1177-54671177-5483https://doaj.org/article/08ee9ed1711d45e89fcb16bc87dc68122013-07-01T00:00:00Zhttp://www.dovepress.com/non-descemetrsquos-stripping-automated-endothelial-keratoplasty-for-bu-a13539https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Teruumi Minezaki, Takaaki Hattori, Hayate Nakagawa, Shigeto Kumakura, Hiroshi GotoDepartment of Ophthalmology, Tokyo Medical University, Shinjukuku, Tokyo, JapanPurpose: To report a case of bullous keratopathy secondary to iridoschisis treated by non-Descemet's stripping automated endothelial keratoplasty (nDSAEK).Case report: A 79-year-old woman was referred to our hospital with loss of vision in the left eye. Slit lamp examination of her left eye showed a shallow anterior chamber with cataract and schisis in the inferior quadrant of iris stroma. Bullous keratopathy secondary to iridoschisis was diagnosed. Cataract surgery with iridectomy succeeded to deepen the anterior chamber and remove the floating iris leaf, although corneal edema remained. Four days later, nDSAEK was performed, which resolved corneal edema and restored visual acuity.Conclusion: The two-step surgery of cataract surgery plus iridectomy followed by nDSAEK may be an effective strategy for treating bullous keratopathy secondary to iridoschisis.Keywords: iridoschisis, bullous keratopathy, non-Descemet's stripping automated endothelial keratoplastyMinezaki THattori TNakagawa HKumakura SGoto HDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2013, Iss default, Pp 1353-1355 (2013)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Minezaki T
Hattori T
Nakagawa H
Kumakura S
Goto H
Non-Descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis
description Teruumi Minezaki, Takaaki Hattori, Hayate Nakagawa, Shigeto Kumakura, Hiroshi GotoDepartment of Ophthalmology, Tokyo Medical University, Shinjukuku, Tokyo, JapanPurpose: To report a case of bullous keratopathy secondary to iridoschisis treated by non-Descemet's stripping automated endothelial keratoplasty (nDSAEK).Case report: A 79-year-old woman was referred to our hospital with loss of vision in the left eye. Slit lamp examination of her left eye showed a shallow anterior chamber with cataract and schisis in the inferior quadrant of iris stroma. Bullous keratopathy secondary to iridoschisis was diagnosed. Cataract surgery with iridectomy succeeded to deepen the anterior chamber and remove the floating iris leaf, although corneal edema remained. Four days later, nDSAEK was performed, which resolved corneal edema and restored visual acuity.Conclusion: The two-step surgery of cataract surgery plus iridectomy followed by nDSAEK may be an effective strategy for treating bullous keratopathy secondary to iridoschisis.Keywords: iridoschisis, bullous keratopathy, non-Descemet's stripping automated endothelial keratoplasty
format article
author Minezaki T
Hattori T
Nakagawa H
Kumakura S
Goto H
author_facet Minezaki T
Hattori T
Nakagawa H
Kumakura S
Goto H
author_sort Minezaki T
title Non-Descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis
title_short Non-Descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis
title_full Non-Descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis
title_fullStr Non-Descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis
title_full_unstemmed Non-Descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis
title_sort non-descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis
publisher Dove Medical Press
publishDate 2013
url https://doaj.org/article/08ee9ed1711d45e89fcb16bc87dc6812
work_keys_str_mv AT minezakit nondescemetrsquosstrippingautomatedendothelialkeratoplastyforbullouskeratopathysecondarytoiridoschisis
AT hattorit nondescemetrsquosstrippingautomatedendothelialkeratoplastyforbullouskeratopathysecondarytoiridoschisis
AT nakagawah nondescemetrsquosstrippingautomatedendothelialkeratoplastyforbullouskeratopathysecondarytoiridoschisis
AT kumakuras nondescemetrsquosstrippingautomatedendothelialkeratoplastyforbullouskeratopathysecondarytoiridoschisis
AT gotoh nondescemetrsquosstrippingautomatedendothelialkeratoplastyforbullouskeratopathysecondarytoiridoschisis
_version_ 1718403177786638336