Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite

Gautam Das, Hyon Hee Yoon Department of Chemical and Biological Engineering, Gachon University, Seongnam, Gyeonggi-do, South Korea Abstract: An electrochemical biosensor based on sulfonated graphene/polyaniline nanocomposite was developed for urea analysis. Oxidative polymerization of aniline in t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Das G, Yoon HH
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2015
Materias:
Acceso en línea:https://doaj.org/article/09aa4999b4094a739fc4663631e4a473
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:09aa4999b4094a739fc4663631e4a473
record_format dspace
spelling oai:doaj.org-article:09aa4999b4094a739fc4663631e4a4732021-12-02T02:29:09ZAmperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite1178-2013https://doaj.org/article/09aa4999b4094a739fc4663631e4a4732015-08-01T00:00:00Zhttp://www.dovepress.com/amperometric-urea-biosensors-based-on-sulfonated-graphenepolyaniline-n-peer-reviewed-article-IJNhttps://doaj.org/toc/1178-2013Gautam Das, Hyon Hee Yoon Department of Chemical and Biological Engineering, Gachon University, Seongnam, Gyeonggi-do, South Korea Abstract: An electrochemical biosensor based on sulfonated graphene/polyaniline nanocomposite was developed for urea analysis. Oxidative polymerization of aniline in the presence of sulfonated graphene oxide was carried out by electrochemical methods in an aqueous environment. The structural properties of the nanocomposite were characterized by Fourier-transform infrared, Raman spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy techniques. The urease enzyme-immobilized sulfonated graphene/polyaniline nanocomposite film showed impressive performance in the electroanalytical detection of urea with a detection limit of 0.050 mM and a sensitivity of 0.85 µA·cm-2·mM-1. The biosensor achieved a broad linear range of detection (0.12–12.3 mM) with a notable response time of approximately 5 seconds. Moreover, the fabricated biosensor retained 81% of its initial activity (based on sensitivity) after 15 days of storage at 4°C. The ease of fabrication coupled with the low cost and good electrochemical performance of this system holds potential for the development of solid-state biosensors for urea detection. Keywords: electrochemical deposition, sulfonated graphene oxide, ureaseDas GYoon HHDove Medical PressarticleMedicine (General)R5-920ENInternational Journal of Nanomedicine, Vol 2015, Iss Special Issue on diverse applications in Nano-Theranostics, Pp 55-66 (2015)
institution DOAJ
collection DOAJ
language EN
topic Medicine (General)
R5-920
spellingShingle Medicine (General)
R5-920
Das G
Yoon HH
Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite
description Gautam Das, Hyon Hee Yoon Department of Chemical and Biological Engineering, Gachon University, Seongnam, Gyeonggi-do, South Korea Abstract: An electrochemical biosensor based on sulfonated graphene/polyaniline nanocomposite was developed for urea analysis. Oxidative polymerization of aniline in the presence of sulfonated graphene oxide was carried out by electrochemical methods in an aqueous environment. The structural properties of the nanocomposite were characterized by Fourier-transform infrared, Raman spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy techniques. The urease enzyme-immobilized sulfonated graphene/polyaniline nanocomposite film showed impressive performance in the electroanalytical detection of urea with a detection limit of 0.050 mM and a sensitivity of 0.85 µA·cm-2·mM-1. The biosensor achieved a broad linear range of detection (0.12–12.3 mM) with a notable response time of approximately 5 seconds. Moreover, the fabricated biosensor retained 81% of its initial activity (based on sensitivity) after 15 days of storage at 4°C. The ease of fabrication coupled with the low cost and good electrochemical performance of this system holds potential for the development of solid-state biosensors for urea detection. Keywords: electrochemical deposition, sulfonated graphene oxide, urease
format article
author Das G
Yoon HH
author_facet Das G
Yoon HH
author_sort Das G
title Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite
title_short Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite
title_full Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite
title_fullStr Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite
title_full_unstemmed Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite
title_sort amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite
publisher Dove Medical Press
publishDate 2015
url https://doaj.org/article/09aa4999b4094a739fc4663631e4a473
work_keys_str_mv AT dasg amperometricureabiosensorsbasedonsulfonatedgraphenepolyanilinenanocomposite
AT yoonhh amperometricureabiosensorsbasedonsulfonatedgraphenepolyanilinenanocomposite
_version_ 1718402448890003456