A biomechanical study comparing the mean load to failure of two different osteosynthesis techniques for step-cut olecranon osteotomy
Background: Olecranon osteotomies are frequently used to expose distal humeral intraarticular fractures. The step-cut olecranon osteotomy (SCOOT) is an augmented version of the oblique olecranon osteotomy, which has recently been evaluated biomechanically with tension band wiring (TBW) fixation. How...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/09c17134782345ee9c6a8e71c846fa7f |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Sea el primero en dejar un comentario!