Diagnostic Performance of Digital Radiograph and Low-Dose Computed Tomography for the Diagnosis of Fishbone Retention in the Oropharynx

Introduction Fishbone foreign body retention is one of the most common problem with various clinical manifestations from asymptomatic, abscess formation, and perforation to mediastinitis with subsequence morbidity and mortality. Accurately identifying the location of the fishbone leads to precise re...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Jirapa Chansangrat
Formato: article
Lenguaje:EN
Publicado: Thieme Revinter Publicações Ltda. 2021
Materias:
ct
R
Acceso en línea:https://doaj.org/article/09c6462b247a45a599d6c041bdc53552
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:09c6462b247a45a599d6c041bdc53552
record_format dspace
spelling oai:doaj.org-article:09c6462b247a45a599d6c041bdc535522021-11-08T23:54:39ZDiagnostic Performance of Digital Radiograph and Low-Dose Computed Tomography for the Diagnosis of Fishbone Retention in the Oropharynx1809-97771809-486410.1055/s-0041-1735567https://doaj.org/article/09c6462b247a45a599d6c041bdc535522021-11-01T00:00:00Zhttp://www.thieme-connect.de/DOI/DOI?10.1055/s-0041-1735567https://doaj.org/toc/1809-9777https://doaj.org/toc/1809-4864Introduction Fishbone foreign body retention is one of the most common problem with various clinical manifestations from asymptomatic, abscess formation, and perforation to mediastinitis with subsequence morbidity and mortality. Accurately identifying the location of the fishbone leads to precise removal, which, in turn, prevents serious consequences. Digital radiographs have been widely used for diagnosis, but many studies show poor sensitivity. Object The present study was designed to compare the diagnostic performances of digital radiograph and low-dose computed tomography (CT) for fishbone retention and to demonstrate the radiation dose of the two modalities. Methods We collected 2 pieces of fishbone from each of the 15 species commonly eaten in Southeast Asia. We embedded each fishbone in a fresh pig's neck, then subjected the pig's neck to lateral soft tissue neck digital radiograph. The locations to embed included tonsil, base of tongue, and upper esophagus. Then, we subjected the same specimen to a CT scan. Two experienced radiologists interpreted each image. Results Visibility in the digital radiograph group was 13%, and in CT images group, it was 87% regardless of the locations. The average radiation dose from digital radiographs was 0.4 mGy (radiation dose field), while from CT images it was 8.6 mGy (CT dose index). Conclusion Most of the common fishbones in Southeast Asia could not be visualized by digital radiograph when embedded in the neck. Computed tomography scans demonstrated better diagnostic performance of fishbone retention compared to digital radiographs, regardless of the embedded location.Jirapa ChansangratThieme Revinter Publicações Ltda.articlefishboneoropharyngealesophagealforeign bodydiagnostic performancectdigital radiographMedicineROtorhinolaryngologyRF1-547ENInternational Archives of Otorhinolaryngology (2021)
institution DOAJ
collection DOAJ
language EN
topic fishbone
oropharyngeal
esophageal
foreign body
diagnostic performance
ct
digital radiograph
Medicine
R
Otorhinolaryngology
RF1-547
spellingShingle fishbone
oropharyngeal
esophageal
foreign body
diagnostic performance
ct
digital radiograph
Medicine
R
Otorhinolaryngology
RF1-547
Jirapa Chansangrat
Diagnostic Performance of Digital Radiograph and Low-Dose Computed Tomography for the Diagnosis of Fishbone Retention in the Oropharynx
description Introduction Fishbone foreign body retention is one of the most common problem with various clinical manifestations from asymptomatic, abscess formation, and perforation to mediastinitis with subsequence morbidity and mortality. Accurately identifying the location of the fishbone leads to precise removal, which, in turn, prevents serious consequences. Digital radiographs have been widely used for diagnosis, but many studies show poor sensitivity. Object The present study was designed to compare the diagnostic performances of digital radiograph and low-dose computed tomography (CT) for fishbone retention and to demonstrate the radiation dose of the two modalities. Methods We collected 2 pieces of fishbone from each of the 15 species commonly eaten in Southeast Asia. We embedded each fishbone in a fresh pig's neck, then subjected the pig's neck to lateral soft tissue neck digital radiograph. The locations to embed included tonsil, base of tongue, and upper esophagus. Then, we subjected the same specimen to a CT scan. Two experienced radiologists interpreted each image. Results Visibility in the digital radiograph group was 13%, and in CT images group, it was 87% regardless of the locations. The average radiation dose from digital radiographs was 0.4 mGy (radiation dose field), while from CT images it was 8.6 mGy (CT dose index). Conclusion Most of the common fishbones in Southeast Asia could not be visualized by digital radiograph when embedded in the neck. Computed tomography scans demonstrated better diagnostic performance of fishbone retention compared to digital radiographs, regardless of the embedded location.
format article
author Jirapa Chansangrat
author_facet Jirapa Chansangrat
author_sort Jirapa Chansangrat
title Diagnostic Performance of Digital Radiograph and Low-Dose Computed Tomography for the Diagnosis of Fishbone Retention in the Oropharynx
title_short Diagnostic Performance of Digital Radiograph and Low-Dose Computed Tomography for the Diagnosis of Fishbone Retention in the Oropharynx
title_full Diagnostic Performance of Digital Radiograph and Low-Dose Computed Tomography for the Diagnosis of Fishbone Retention in the Oropharynx
title_fullStr Diagnostic Performance of Digital Radiograph and Low-Dose Computed Tomography for the Diagnosis of Fishbone Retention in the Oropharynx
title_full_unstemmed Diagnostic Performance of Digital Radiograph and Low-Dose Computed Tomography for the Diagnosis of Fishbone Retention in the Oropharynx
title_sort diagnostic performance of digital radiograph and low-dose computed tomography for the diagnosis of fishbone retention in the oropharynx
publisher Thieme Revinter Publicações Ltda.
publishDate 2021
url https://doaj.org/article/09c6462b247a45a599d6c041bdc53552
work_keys_str_mv AT jirapachansangrat diagnosticperformanceofdigitalradiographandlowdosecomputedtomographyforthediagnosisoffishboneretentionintheoropharynx
_version_ 1718441358409072640