Rapid and quantitative detection of C-reactive protein based on quantum dots and immunofiltration assay

Pengfei Zhang,1,* Yan Bao,1,* Mohamed Shehata Draz,2,3,* Huiqi Lu,1 Chang Liu,1 Huanxing Han11Center for Translational Medicine, Changzheng Hospital, Second Military Medical University, Shanghai, People’s Republic of China; 2Zhejiang-California International Nanosystems Institute, Zhejiang...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Zhang PF, Bao Y, Draz MS, Lu HQ, Liu C, Han HX
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2015
Materias:
Acceso en línea:https://doaj.org/article/0a4821def47849a7838fd3202f5176a5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:0a4821def47849a7838fd3202f5176a5
record_format dspace
spelling oai:doaj.org-article:0a4821def47849a7838fd3202f5176a52021-12-02T02:31:41ZRapid and quantitative detection of C-reactive protein based on quantum dots and immunofiltration assay1178-2013https://doaj.org/article/0a4821def47849a7838fd3202f5176a52015-09-01T00:00:00Zhttps://www.dovepress.com/rapid-and-quantitative-detection-of-c-reactive-protein-based-on-quantu-peer-reviewed-article-IJNhttps://doaj.org/toc/1178-2013Pengfei Zhang,1,* Yan Bao,1,* Mohamed Shehata Draz,2,3,* Huiqi Lu,1 Chang Liu,1 Huanxing Han11Center for Translational Medicine, Changzheng Hospital, Second Military Medical University, Shanghai, People’s Republic of China; 2Zhejiang-California International Nanosystems Institute, Zhejiang University, Hangzhou, Zhejiang, People’s Republic of China; 3Faculty of Science, Tanta University, Tanta, Egypt*These authors contributed equally to this workAbstract: Convenient and rapid immunofiltration assays (IFAs) enable on-site “yes” or “no” determination of disease markers. However, traditional IFAs are commonly qualitative or semi-quantitative and are very limited for the efficient testing of samples in field diagnostics. Here, we overcome these limitations by developing a quantum dots (QDs)-based fluorescent IFA for the quantitative detection of C-reactive proteins (CRP). CRP, the well-known diagnostic marker for acute viral and bacterial infections, was used as a model analyte to demonstrate performance and sensitivity of our developed QDs-based IFA. QDs capped with both polyethylene glycol (PEG) and glutathione were used as fluorescent labels for our IFAs. The presence of the surface PEG layer, which reduced the non-specific protein interactions, in conjunction with the inherent optical properties of QDs, resulted in lower background signal, increased sensitivity, and ability to detect CRP down to 0.79 mg/L with only 5 µL serum sample. In addition, the developed assay is simple, fast and can quantitatively detect CRP with a detection limit up to 200 mg/L. Clinical test results of our QD-based IFA are well correlated with the traditional latex enhance immune-agglutination aggregation. The proposed QD-based fluorescent IFA is very promising, and potentially will be adopted for multiplexed immunoassay and in field point-of-care test.Keywords: C-reactive proteins, point-of-care test, Glutathione capped QDs, PEGylationZhang PFBao YDraz MSLu HQLiu CHan HXDove Medical PressarticleMedicine (General)R5-920ENInternational Journal of Nanomedicine, Vol 2015, Iss default, Pp 6161-6173 (2015)
institution DOAJ
collection DOAJ
language EN
topic Medicine (General)
R5-920
spellingShingle Medicine (General)
R5-920
Zhang PF
Bao Y
Draz MS
Lu HQ
Liu C
Han HX
Rapid and quantitative detection of C-reactive protein based on quantum dots and immunofiltration assay
description Pengfei Zhang,1,* Yan Bao,1,* Mohamed Shehata Draz,2,3,* Huiqi Lu,1 Chang Liu,1 Huanxing Han11Center for Translational Medicine, Changzheng Hospital, Second Military Medical University, Shanghai, People’s Republic of China; 2Zhejiang-California International Nanosystems Institute, Zhejiang University, Hangzhou, Zhejiang, People’s Republic of China; 3Faculty of Science, Tanta University, Tanta, Egypt*These authors contributed equally to this workAbstract: Convenient and rapid immunofiltration assays (IFAs) enable on-site “yes” or “no” determination of disease markers. However, traditional IFAs are commonly qualitative or semi-quantitative and are very limited for the efficient testing of samples in field diagnostics. Here, we overcome these limitations by developing a quantum dots (QDs)-based fluorescent IFA for the quantitative detection of C-reactive proteins (CRP). CRP, the well-known diagnostic marker for acute viral and bacterial infections, was used as a model analyte to demonstrate performance and sensitivity of our developed QDs-based IFA. QDs capped with both polyethylene glycol (PEG) and glutathione were used as fluorescent labels for our IFAs. The presence of the surface PEG layer, which reduced the non-specific protein interactions, in conjunction with the inherent optical properties of QDs, resulted in lower background signal, increased sensitivity, and ability to detect CRP down to 0.79 mg/L with only 5 µL serum sample. In addition, the developed assay is simple, fast and can quantitatively detect CRP with a detection limit up to 200 mg/L. Clinical test results of our QD-based IFA are well correlated with the traditional latex enhance immune-agglutination aggregation. The proposed QD-based fluorescent IFA is very promising, and potentially will be adopted for multiplexed immunoassay and in field point-of-care test.Keywords: C-reactive proteins, point-of-care test, Glutathione capped QDs, PEGylation
format article
author Zhang PF
Bao Y
Draz MS
Lu HQ
Liu C
Han HX
author_facet Zhang PF
Bao Y
Draz MS
Lu HQ
Liu C
Han HX
author_sort Zhang PF
title Rapid and quantitative detection of C-reactive protein based on quantum dots and immunofiltration assay
title_short Rapid and quantitative detection of C-reactive protein based on quantum dots and immunofiltration assay
title_full Rapid and quantitative detection of C-reactive protein based on quantum dots and immunofiltration assay
title_fullStr Rapid and quantitative detection of C-reactive protein based on quantum dots and immunofiltration assay
title_full_unstemmed Rapid and quantitative detection of C-reactive protein based on quantum dots and immunofiltration assay
title_sort rapid and quantitative detection of c-reactive protein based on quantum dots and immunofiltration assay
publisher Dove Medical Press
publishDate 2015
url https://doaj.org/article/0a4821def47849a7838fd3202f5176a5
work_keys_str_mv AT zhangpf rapidandquantitativedetectionofcreactiveproteinbasedonquantumdotsandimmunofiltrationassay
AT baoy rapidandquantitativedetectionofcreactiveproteinbasedonquantumdotsandimmunofiltrationassay
AT drazms rapidandquantitativedetectionofcreactiveproteinbasedonquantumdotsandimmunofiltrationassay
AT luhq rapidandquantitativedetectionofcreactiveproteinbasedonquantumdotsandimmunofiltrationassay
AT liuc rapidandquantitativedetectionofcreactiveproteinbasedonquantumdotsandimmunofiltrationassay
AT hanhx rapidandquantitativedetectionofcreactiveproteinbasedonquantumdotsandimmunofiltrationassay
_version_ 1718402388349419520