A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds
The precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardi...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/0aab52389d984bc58851478e506d68ae |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:0aab52389d984bc58851478e506d68ae |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:0aab52389d984bc58851478e506d68ae2021-11-18T08:40:11ZA Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds1664-042X10.3389/fphys.2021.725716https://doaj.org/article/0aab52389d984bc58851478e506d68ae2021-11-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fphys.2021.725716/fullhttps://doaj.org/toc/1664-042XThe precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardiography (FCG) is a non-invasive technique that measures these vibrations via force sensing resistors (FSR). This study presents a new piezoelectric sensor able to record all heart vibrations simultaneously, as well as a respiration signal. The new sensor was compared to the FSR-based one to assess its suitability for FCG. An electrocardiogram (ECG) lead and a signal from an electro-resistive respiration band (ERB) were synchronously acquired as references on six healthy volunteers (4 males, 2 females) at rest. The raw signals from the piezoelectric and the FSR-based sensors turned out to be very similar. The raw signals were divided into four components: Forcerespirogram (FRG), Low-Frequency FCG (LF-FCG), High-Frequency FCG (HF-FCG) and heart sounds (HS-FCG). A beat-by-beat comparison of FCG and ECG signals was carried out by means of regression, correlation and Bland–Altman analyses, and similarly for respiration signals (FRG and ERB). The results showed that the infrasonic FCG components are strongly related to the cardiac cycle (R2 > 0.999, null bias and Limits of Agreement (LoA) of ± 4.9 ms for HF-FCG; R2 > 0.99, null bias and LoA of ± 26.9 ms for LF-FCG) and the FRG inter-breath intervals are consistent with ERB ones (R2 > 0.99, non-significant bias and LoA of ± 0.46 s). Furthermore, the piezoelectric sensor was tested against an accelerometer and an electronic stethoscope: synchronous acquisitions were performed to quantify the similarity between the signals. ECG-triggered ensemble averages (synchronized with R-peaks) of HF-FCG and SCG showed a correlation greater than 0.81, while those of HS-FCG and PCG scored a correlation greater than 0.85. The piezoelectric sensor demonstrated superior performances as compared to the FSR, providing more accurate, beat-by-beat measurements. This is the first time that a single piezoelectric sensor demonstrated the ability to simultaneously capture respiration, heart sounds, an SCG-like signal (i.e., HF-FCG) and the LF-FCG signal, which may provide information on ventricular emptying and filling events. According to these preliminary results the novel piezoelectric FCG sensor stands as a promising device for accurate, unobtrusive, long-term monitoring of cardiorespiratory functions and paves the way for a wide range of potential applications, both in the research and clinical fields. However, these results should be confirmed by further analyses on a larger cohort of subjects, possibly including also pathological patients.Emilio AndreozziGaetano D. GargiuloDaniele EspositoPaolo BifulcoFrontiers Media S.A.articleforcecardiographyseismocardiographyheart soundsrespirationheart vibrationspiezoelectric sensorPhysiologyQP1-981ENFrontiers in Physiology, Vol 12 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
forcecardiography seismocardiography heart sounds respiration heart vibrations piezoelectric sensor Physiology QP1-981 |
spellingShingle |
forcecardiography seismocardiography heart sounds respiration heart vibrations piezoelectric sensor Physiology QP1-981 Emilio Andreozzi Gaetano D. Gargiulo Daniele Esposito Paolo Bifulco A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds |
description |
The precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardiography (FCG) is a non-invasive technique that measures these vibrations via force sensing resistors (FSR). This study presents a new piezoelectric sensor able to record all heart vibrations simultaneously, as well as a respiration signal. The new sensor was compared to the FSR-based one to assess its suitability for FCG. An electrocardiogram (ECG) lead and a signal from an electro-resistive respiration band (ERB) were synchronously acquired as references on six healthy volunteers (4 males, 2 females) at rest. The raw signals from the piezoelectric and the FSR-based sensors turned out to be very similar. The raw signals were divided into four components: Forcerespirogram (FRG), Low-Frequency FCG (LF-FCG), High-Frequency FCG (HF-FCG) and heart sounds (HS-FCG). A beat-by-beat comparison of FCG and ECG signals was carried out by means of regression, correlation and Bland–Altman analyses, and similarly for respiration signals (FRG and ERB). The results showed that the infrasonic FCG components are strongly related to the cardiac cycle (R2 > 0.999, null bias and Limits of Agreement (LoA) of ± 4.9 ms for HF-FCG; R2 > 0.99, null bias and LoA of ± 26.9 ms for LF-FCG) and the FRG inter-breath intervals are consistent with ERB ones (R2 > 0.99, non-significant bias and LoA of ± 0.46 s). Furthermore, the piezoelectric sensor was tested against an accelerometer and an electronic stethoscope: synchronous acquisitions were performed to quantify the similarity between the signals. ECG-triggered ensemble averages (synchronized with R-peaks) of HF-FCG and SCG showed a correlation greater than 0.81, while those of HS-FCG and PCG scored a correlation greater than 0.85. The piezoelectric sensor demonstrated superior performances as compared to the FSR, providing more accurate, beat-by-beat measurements. This is the first time that a single piezoelectric sensor demonstrated the ability to simultaneously capture respiration, heart sounds, an SCG-like signal (i.e., HF-FCG) and the LF-FCG signal, which may provide information on ventricular emptying and filling events. According to these preliminary results the novel piezoelectric FCG sensor stands as a promising device for accurate, unobtrusive, long-term monitoring of cardiorespiratory functions and paves the way for a wide range of potential applications, both in the research and clinical fields. However, these results should be confirmed by further analyses on a larger cohort of subjects, possibly including also pathological patients. |
format |
article |
author |
Emilio Andreozzi Gaetano D. Gargiulo Daniele Esposito Paolo Bifulco |
author_facet |
Emilio Andreozzi Gaetano D. Gargiulo Daniele Esposito Paolo Bifulco |
author_sort |
Emilio Andreozzi |
title |
A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds |
title_short |
A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds |
title_full |
A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds |
title_fullStr |
A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds |
title_full_unstemmed |
A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds |
title_sort |
novel broadband forcecardiography sensor for simultaneous monitoring of respiration, infrasonic cardiac vibrations and heart sounds |
publisher |
Frontiers Media S.A. |
publishDate |
2021 |
url |
https://doaj.org/article/0aab52389d984bc58851478e506d68ae |
work_keys_str_mv |
AT emilioandreozzi anovelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds AT gaetanodgargiulo anovelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds AT danieleesposito anovelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds AT paolobifulco anovelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds AT emilioandreozzi novelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds AT gaetanodgargiulo novelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds AT danieleesposito novelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds AT paolobifulco novelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds |
_version_ |
1718421482940399616 |