A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds

The precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Emilio Andreozzi, Gaetano D. Gargiulo, Daniele Esposito, Paolo Bifulco
Formato: article
Lenguaje:EN
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://doaj.org/article/0aab52389d984bc58851478e506d68ae
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:0aab52389d984bc58851478e506d68ae
record_format dspace
spelling oai:doaj.org-article:0aab52389d984bc58851478e506d68ae2021-11-18T08:40:11ZA Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds1664-042X10.3389/fphys.2021.725716https://doaj.org/article/0aab52389d984bc58851478e506d68ae2021-11-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fphys.2021.725716/fullhttps://doaj.org/toc/1664-042XThe precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardiography (FCG) is a non-invasive technique that measures these vibrations via force sensing resistors (FSR). This study presents a new piezoelectric sensor able to record all heart vibrations simultaneously, as well as a respiration signal. The new sensor was compared to the FSR-based one to assess its suitability for FCG. An electrocardiogram (ECG) lead and a signal from an electro-resistive respiration band (ERB) were synchronously acquired as references on six healthy volunteers (4 males, 2 females) at rest. The raw signals from the piezoelectric and the FSR-based sensors turned out to be very similar. The raw signals were divided into four components: Forcerespirogram (FRG), Low-Frequency FCG (LF-FCG), High-Frequency FCG (HF-FCG) and heart sounds (HS-FCG). A beat-by-beat comparison of FCG and ECG signals was carried out by means of regression, correlation and Bland–Altman analyses, and similarly for respiration signals (FRG and ERB). The results showed that the infrasonic FCG components are strongly related to the cardiac cycle (R2 > 0.999, null bias and Limits of Agreement (LoA) of ± 4.9 ms for HF-FCG; R2 > 0.99, null bias and LoA of ± 26.9 ms for LF-FCG) and the FRG inter-breath intervals are consistent with ERB ones (R2 > 0.99, non-significant bias and LoA of ± 0.46 s). Furthermore, the piezoelectric sensor was tested against an accelerometer and an electronic stethoscope: synchronous acquisitions were performed to quantify the similarity between the signals. ECG-triggered ensemble averages (synchronized with R-peaks) of HF-FCG and SCG showed a correlation greater than 0.81, while those of HS-FCG and PCG scored a correlation greater than 0.85. The piezoelectric sensor demonstrated superior performances as compared to the FSR, providing more accurate, beat-by-beat measurements. This is the first time that a single piezoelectric sensor demonstrated the ability to simultaneously capture respiration, heart sounds, an SCG-like signal (i.e., HF-FCG) and the LF-FCG signal, which may provide information on ventricular emptying and filling events. According to these preliminary results the novel piezoelectric FCG sensor stands as a promising device for accurate, unobtrusive, long-term monitoring of cardiorespiratory functions and paves the way for a wide range of potential applications, both in the research and clinical fields. However, these results should be confirmed by further analyses on a larger cohort of subjects, possibly including also pathological patients.Emilio AndreozziGaetano D. GargiuloDaniele EspositoPaolo BifulcoFrontiers Media S.A.articleforcecardiographyseismocardiographyheart soundsrespirationheart vibrationspiezoelectric sensorPhysiologyQP1-981ENFrontiers in Physiology, Vol 12 (2021)
institution DOAJ
collection DOAJ
language EN
topic forcecardiography
seismocardiography
heart sounds
respiration
heart vibrations
piezoelectric sensor
Physiology
QP1-981
spellingShingle forcecardiography
seismocardiography
heart sounds
respiration
heart vibrations
piezoelectric sensor
Physiology
QP1-981
Emilio Andreozzi
Gaetano D. Gargiulo
Daniele Esposito
Paolo Bifulco
A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds
description The precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardiography (FCG) is a non-invasive technique that measures these vibrations via force sensing resistors (FSR). This study presents a new piezoelectric sensor able to record all heart vibrations simultaneously, as well as a respiration signal. The new sensor was compared to the FSR-based one to assess its suitability for FCG. An electrocardiogram (ECG) lead and a signal from an electro-resistive respiration band (ERB) were synchronously acquired as references on six healthy volunteers (4 males, 2 females) at rest. The raw signals from the piezoelectric and the FSR-based sensors turned out to be very similar. The raw signals were divided into four components: Forcerespirogram (FRG), Low-Frequency FCG (LF-FCG), High-Frequency FCG (HF-FCG) and heart sounds (HS-FCG). A beat-by-beat comparison of FCG and ECG signals was carried out by means of regression, correlation and Bland–Altman analyses, and similarly for respiration signals (FRG and ERB). The results showed that the infrasonic FCG components are strongly related to the cardiac cycle (R2 > 0.999, null bias and Limits of Agreement (LoA) of ± 4.9 ms for HF-FCG; R2 > 0.99, null bias and LoA of ± 26.9 ms for LF-FCG) and the FRG inter-breath intervals are consistent with ERB ones (R2 > 0.99, non-significant bias and LoA of ± 0.46 s). Furthermore, the piezoelectric sensor was tested against an accelerometer and an electronic stethoscope: synchronous acquisitions were performed to quantify the similarity between the signals. ECG-triggered ensemble averages (synchronized with R-peaks) of HF-FCG and SCG showed a correlation greater than 0.81, while those of HS-FCG and PCG scored a correlation greater than 0.85. The piezoelectric sensor demonstrated superior performances as compared to the FSR, providing more accurate, beat-by-beat measurements. This is the first time that a single piezoelectric sensor demonstrated the ability to simultaneously capture respiration, heart sounds, an SCG-like signal (i.e., HF-FCG) and the LF-FCG signal, which may provide information on ventricular emptying and filling events. According to these preliminary results the novel piezoelectric FCG sensor stands as a promising device for accurate, unobtrusive, long-term monitoring of cardiorespiratory functions and paves the way for a wide range of potential applications, both in the research and clinical fields. However, these results should be confirmed by further analyses on a larger cohort of subjects, possibly including also pathological patients.
format article
author Emilio Andreozzi
Gaetano D. Gargiulo
Daniele Esposito
Paolo Bifulco
author_facet Emilio Andreozzi
Gaetano D. Gargiulo
Daniele Esposito
Paolo Bifulco
author_sort Emilio Andreozzi
title A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds
title_short A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds
title_full A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds
title_fullStr A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds
title_full_unstemmed A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds
title_sort novel broadband forcecardiography sensor for simultaneous monitoring of respiration, infrasonic cardiac vibrations and heart sounds
publisher Frontiers Media S.A.
publishDate 2021
url https://doaj.org/article/0aab52389d984bc58851478e506d68ae
work_keys_str_mv AT emilioandreozzi anovelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds
AT gaetanodgargiulo anovelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds
AT danieleesposito anovelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds
AT paolobifulco anovelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds
AT emilioandreozzi novelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds
AT gaetanodgargiulo novelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds
AT danieleesposito novelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds
AT paolobifulco novelbroadbandforcecardiographysensorforsimultaneousmonitoringofrespirationinfrasoniccardiacvibrationsandheartsounds
_version_ 1718421482940399616