Comparison of Macular Pigment Optical Density in Glaucoma Patients and Healthy Subjects – A Prospective Diagnostic Study

Yannick Bruns,1,* Bernd Junker,1,* Daniel Boehringer,2 Carsten Framme,1 Amelie Pielen1 1University Eye Hospital, Hannover Medical School, Hannover 30625, Germany; 2Clinic for Ophthalmology, University of Freiburg Faculty of Medicine, Freiburg 79106, Germany*These authors contributed equally to this...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bruns Y, Junker B, Boehringer D, Framme C, Pielen A
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2020
Materias:
Acceso en línea:https://doaj.org/article/0aefc12c7f8c4530bbcb06ca5c4b0784
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:0aefc12c7f8c4530bbcb06ca5c4b0784
record_format dspace
spelling oai:doaj.org-article:0aefc12c7f8c4530bbcb06ca5c4b07842021-12-02T05:07:06ZComparison of Macular Pigment Optical Density in Glaucoma Patients and Healthy Subjects – A Prospective Diagnostic Study1177-5483https://doaj.org/article/0aefc12c7f8c4530bbcb06ca5c4b07842020-04-01T00:00:00Zhttps://www.dovepress.com/comparison-of-macular-pigment-optical-density-in-glaucoma-patients-and-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Yannick Bruns,1,* Bernd Junker,1,* Daniel Boehringer,2 Carsten Framme,1 Amelie Pielen1 1University Eye Hospital, Hannover Medical School, Hannover 30625, Germany; 2Clinic for Ophthalmology, University of Freiburg Faculty of Medicine, Freiburg 79106, Germany*These authors contributed equally to this workCorrespondence: Yannick BrunsUniversity Eye Hospital, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, GermanyTel +4915117677363Email bruns.yannick@mh-hannover.dePurpose: To evaluate the relationship between macular pigment optical density (MPOD) and glaucoma.Methods: Forty-three patients with an established glaucoma diagnosis (25 females, 18 males, mean age 70 (range 34– 84)) and 43 healthy controls (28 females, 15 males, mean age 62 (range 30– 87)) were included in this prospective diagnostic case-control study. All subjects underwent detailed eye examination including ophthalmoscopy, best-corrected visual acuity, biomicroscopy, measurement of the axial length of the eye, objective refraction, lens status, central foveal thickness on spectral-domain optical coherence tomography (SD-OCT). In all glaucoma patients, a visual field assessment and a measurement of the retinal nerve fibre layer (RNFL) on SD-OCT were done. MPOD was determined using the macula pigment module of the Spectralis HRA+OCT (Heidelberg Engineering GmbH, Heidelberg, Germany) at 0.51°, 1.02° and 1.99° retinal eccentricity using two-wavelength autofluorescence imaging.Results: In the glaucoma group, the median of the visual field mean defect was 5.1 db (quartiles 3.0 and 13.5) and the mean RNFL-thickness global was 65.9 μm (SD ± 16.1). Median MPOD measured at 0.51°, 1.02° and 1.99° retinal eccentricity in the glaucoma group was 0.42 DU, 0.34 DU and 0.13 DU, in the control group 0.40 DU, 0.35 DU and 0.12 DU respectively. There was no statistically significant difference of median MPOD between glaucomatous and control eyes (p=0.510, 0.735, 0.481). No significant relation between MPOD at 1.02 retinal eccentricity and the presence of glare symptoms was found (p=0.948). However, age seems to correlate with median MPOD measured at 1.02 retinal eccentricity (p=0.017).Conclusion: There was no evidence for lower MPOD levels in our glaucoma patients; lower MPOD was not related to the presence of glare symptoms. However there seems to be a positive correlation between age and MPOD at 1.02° retinal eccentricity. To further investigate the relation between glare reported by glaucoma patients and glare disability linked to lower MPOD levels, additional studies are necessary that include both detailed inquiry of the quality of glare and a glare quantification and precise analysis of MPOD levels in glaucoma patients.Keywords: glaucoma, macular pigment optical density, glare, case-control studyBruns YJunker BBoehringer DFramme CPielen ADove Medical Pressarticleglaucomamacular pigment optical densityglarecase-control studyOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 14, Pp 1011-1017 (2020)
institution DOAJ
collection DOAJ
language EN
topic glaucoma
macular pigment optical density
glare
case-control study
Ophthalmology
RE1-994
spellingShingle glaucoma
macular pigment optical density
glare
case-control study
Ophthalmology
RE1-994
Bruns Y
Junker B
Boehringer D
Framme C
Pielen A
Comparison of Macular Pigment Optical Density in Glaucoma Patients and Healthy Subjects – A Prospective Diagnostic Study
description Yannick Bruns,1,* Bernd Junker,1,* Daniel Boehringer,2 Carsten Framme,1 Amelie Pielen1 1University Eye Hospital, Hannover Medical School, Hannover 30625, Germany; 2Clinic for Ophthalmology, University of Freiburg Faculty of Medicine, Freiburg 79106, Germany*These authors contributed equally to this workCorrespondence: Yannick BrunsUniversity Eye Hospital, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, GermanyTel +4915117677363Email bruns.yannick@mh-hannover.dePurpose: To evaluate the relationship between macular pigment optical density (MPOD) and glaucoma.Methods: Forty-three patients with an established glaucoma diagnosis (25 females, 18 males, mean age 70 (range 34– 84)) and 43 healthy controls (28 females, 15 males, mean age 62 (range 30– 87)) were included in this prospective diagnostic case-control study. All subjects underwent detailed eye examination including ophthalmoscopy, best-corrected visual acuity, biomicroscopy, measurement of the axial length of the eye, objective refraction, lens status, central foveal thickness on spectral-domain optical coherence tomography (SD-OCT). In all glaucoma patients, a visual field assessment and a measurement of the retinal nerve fibre layer (RNFL) on SD-OCT were done. MPOD was determined using the macula pigment module of the Spectralis HRA+OCT (Heidelberg Engineering GmbH, Heidelberg, Germany) at 0.51°, 1.02° and 1.99° retinal eccentricity using two-wavelength autofluorescence imaging.Results: In the glaucoma group, the median of the visual field mean defect was 5.1 db (quartiles 3.0 and 13.5) and the mean RNFL-thickness global was 65.9 μm (SD ± 16.1). Median MPOD measured at 0.51°, 1.02° and 1.99° retinal eccentricity in the glaucoma group was 0.42 DU, 0.34 DU and 0.13 DU, in the control group 0.40 DU, 0.35 DU and 0.12 DU respectively. There was no statistically significant difference of median MPOD between glaucomatous and control eyes (p=0.510, 0.735, 0.481). No significant relation between MPOD at 1.02 retinal eccentricity and the presence of glare symptoms was found (p=0.948). However, age seems to correlate with median MPOD measured at 1.02 retinal eccentricity (p=0.017).Conclusion: There was no evidence for lower MPOD levels in our glaucoma patients; lower MPOD was not related to the presence of glare symptoms. However there seems to be a positive correlation between age and MPOD at 1.02° retinal eccentricity. To further investigate the relation between glare reported by glaucoma patients and glare disability linked to lower MPOD levels, additional studies are necessary that include both detailed inquiry of the quality of glare and a glare quantification and precise analysis of MPOD levels in glaucoma patients.Keywords: glaucoma, macular pigment optical density, glare, case-control study
format article
author Bruns Y
Junker B
Boehringer D
Framme C
Pielen A
author_facet Bruns Y
Junker B
Boehringer D
Framme C
Pielen A
author_sort Bruns Y
title Comparison of Macular Pigment Optical Density in Glaucoma Patients and Healthy Subjects – A Prospective Diagnostic Study
title_short Comparison of Macular Pigment Optical Density in Glaucoma Patients and Healthy Subjects – A Prospective Diagnostic Study
title_full Comparison of Macular Pigment Optical Density in Glaucoma Patients and Healthy Subjects – A Prospective Diagnostic Study
title_fullStr Comparison of Macular Pigment Optical Density in Glaucoma Patients and Healthy Subjects – A Prospective Diagnostic Study
title_full_unstemmed Comparison of Macular Pigment Optical Density in Glaucoma Patients and Healthy Subjects – A Prospective Diagnostic Study
title_sort comparison of macular pigment optical density in glaucoma patients and healthy subjects – a prospective diagnostic study
publisher Dove Medical Press
publishDate 2020
url https://doaj.org/article/0aefc12c7f8c4530bbcb06ca5c4b0784
work_keys_str_mv AT brunsy comparisonofmacularpigmentopticaldensityinglaucomapatientsandhealthysubjectsndashaprospectivediagnosticstudy
AT junkerb comparisonofmacularpigmentopticaldensityinglaucomapatientsandhealthysubjectsndashaprospectivediagnosticstudy
AT boehringerd comparisonofmacularpigmentopticaldensityinglaucomapatientsandhealthysubjectsndashaprospectivediagnosticstudy
AT frammec comparisonofmacularpigmentopticaldensityinglaucomapatientsandhealthysubjectsndashaprospectivediagnosticstudy
AT pielena comparisonofmacularpigmentopticaldensityinglaucomapatientsandhealthysubjectsndashaprospectivediagnosticstudy
_version_ 1718400572748464128