ebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage

Ross W McQuivey,1 Jon E Block,2 Robert A Massaro3 1Clinical Innovations, Salt Lake City, UT, USA; 2Independent Clinical Consultant, San Francisco, CA, USA; 3Monmouth Medical Center, Long Branch, NJ, USA Abstract: As a leading cause of maternal death, postpartum hemorrhage (PPH) remains a worldwide o...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: McQuivey RW, Block JE, Massaro RA
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://doaj.org/article/0b0bbda4f0e44e2aad8b355057764f07
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:0b0bbda4f0e44e2aad8b355057764f07
record_format dspace
spelling oai:doaj.org-article:0b0bbda4f0e44e2aad8b355057764f072021-12-02T03:12:08Zebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage1179-1470https://doaj.org/article/0b0bbda4f0e44e2aad8b355057764f072018-03-01T00:00:00Zhttps://www.dovepress.com/ebbreg-complete-tamponade-system-effective-hemostasis-for-postpartum-h-peer-reviewed-article-MDERhttps://doaj.org/toc/1179-1470Ross W McQuivey,1 Jon E Block,2 Robert A Massaro3 1Clinical Innovations, Salt Lake City, UT, USA; 2Independent Clinical Consultant, San Francisco, CA, USA; 3Monmouth Medical Center, Long Branch, NJ, USA Abstract: As a leading cause of maternal death, postpartum hemorrhage (PPH) remains a worldwide obstetrical problem. However, in most cases, mortality and morbidity can be averted if efforts are immediately undertaken to achieve hemostasis. Uterine balloon tamponade has been shown to provide effective control of PPH and avoid more invasive surgical procedures and even the emergency peripartum hysterectomy. Recent clinical recommendation suggests that balloon tamponade should be considered earlier in the treatment cascade in conjunction with uterotonic agents to ensure hemostasis in the most timely fashion and maximize clinical outcomes. This paper profiles the ebb® Complete Tamponade System, a unique dual-balloon single-use device that was developed specifically for hemostatic management of PPH. The ebb system combines a uterine conforming balloon that can be rapidly deployed with a vaginal balloon that eliminates the need for vaginal packing. The description, indications for use, procedural steps, and clinical characterization of this device are presented. Keywords: postpartum hemorrhage, balloon tamponade, hemostasis, maternal bleedingMcQuivey RWBlock JEMassaro RADove Medical Pressarticlepostpartum hemorrhageballoon tamponadehemostasismaternal bleedingMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol Volume 11, Pp 57-63 (2018)
institution DOAJ
collection DOAJ
language EN
topic postpartum hemorrhage
balloon tamponade
hemostasis
maternal bleeding
Medical technology
R855-855.5
spellingShingle postpartum hemorrhage
balloon tamponade
hemostasis
maternal bleeding
Medical technology
R855-855.5
McQuivey RW
Block JE
Massaro RA
ebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage
description Ross W McQuivey,1 Jon E Block,2 Robert A Massaro3 1Clinical Innovations, Salt Lake City, UT, USA; 2Independent Clinical Consultant, San Francisco, CA, USA; 3Monmouth Medical Center, Long Branch, NJ, USA Abstract: As a leading cause of maternal death, postpartum hemorrhage (PPH) remains a worldwide obstetrical problem. However, in most cases, mortality and morbidity can be averted if efforts are immediately undertaken to achieve hemostasis. Uterine balloon tamponade has been shown to provide effective control of PPH and avoid more invasive surgical procedures and even the emergency peripartum hysterectomy. Recent clinical recommendation suggests that balloon tamponade should be considered earlier in the treatment cascade in conjunction with uterotonic agents to ensure hemostasis in the most timely fashion and maximize clinical outcomes. This paper profiles the ebb® Complete Tamponade System, a unique dual-balloon single-use device that was developed specifically for hemostatic management of PPH. The ebb system combines a uterine conforming balloon that can be rapidly deployed with a vaginal balloon that eliminates the need for vaginal packing. The description, indications for use, procedural steps, and clinical characterization of this device are presented. Keywords: postpartum hemorrhage, balloon tamponade, hemostasis, maternal bleeding
format article
author McQuivey RW
Block JE
Massaro RA
author_facet McQuivey RW
Block JE
Massaro RA
author_sort McQuivey RW
title ebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage
title_short ebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage
title_full ebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage
title_fullStr ebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage
title_full_unstemmed ebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage
title_sort ebb® complete tamponade system: effective hemostasis for postpartum hemorrhage
publisher Dove Medical Press
publishDate 2018
url https://doaj.org/article/0b0bbda4f0e44e2aad8b355057764f07
work_keys_str_mv AT mcquiveyrw ebbregcompletetamponadesystemeffectivehemostasisforpostpartumhemorrhage
AT blockje ebbregcompletetamponadesystemeffectivehemostasisforpostpartumhemorrhage
AT massarora ebbregcompletetamponadesystemeffectivehemostasisforpostpartumhemorrhage
_version_ 1718401835389157376