Stability Metric Based on Sensitivity Analysis Applied to Electrical Repowering System

Stability metrics are used to quantify a system’s ability to maintain equilibrium under disturbances. We did not identify the proposition of a stability metric using sensitivity analysis within the literature. This work proposes a system stability metric and its application to an electrical repoweri...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: João R. B. Paiva, Alana S. Magalhães, Pedro H. F. Moraes, Júnio S. Bulhões, Wesley P. Calixto
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
T
Acceso en línea:https://doaj.org/article/0ced7d5e0ba043eab58c36bc251de559
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:0ced7d5e0ba043eab58c36bc251de559
record_format dspace
spelling oai:doaj.org-article:0ced7d5e0ba043eab58c36bc251de5592021-11-25T17:29:02ZStability Metric Based on Sensitivity Analysis Applied to Electrical Repowering System10.3390/en142278241996-1073https://doaj.org/article/0ced7d5e0ba043eab58c36bc251de5592021-11-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/22/7824https://doaj.org/toc/1996-1073Stability metrics are used to quantify a system’s ability to maintain equilibrium under disturbances. We did not identify the proposition of a stability metric using sensitivity analysis within the literature. This work proposes a system stability metric and its application to an electrical repowering system. The methodology for applying the proposed metric comprises: (i) system parameters sensitivity analysis and spider diagram construction, (ii) determining the array containing the line segments inclination angles of each spider diagram curve, and (iii) stability calculation using the array mean and maximum inclination value of a line segment. After simulating the model built for the electrical repowering system and applying the methodology, we obtain results regarding the sensitivity indices and stability values of system inputs relative to their outputs, considering the original system and with reduced parameters. Using the stability study, it was possible to determine different stability categories for the system parameters, which indicates the need for different analysis levels.João R. B. PaivaAlana S. MagalhãesPedro H. F. MoraesJúnio S. BulhõesWesley P. CalixtoMDPI AGarticlestability metricelectric repoweringsensitivity analysisparameter suppressionTechnologyTENEnergies, Vol 14, Iss 7824, p 7824 (2021)
institution DOAJ
collection DOAJ
language EN
topic stability metric
electric repowering
sensitivity analysis
parameter suppression
Technology
T
spellingShingle stability metric
electric repowering
sensitivity analysis
parameter suppression
Technology
T
João R. B. Paiva
Alana S. Magalhães
Pedro H. F. Moraes
Júnio S. Bulhões
Wesley P. Calixto
Stability Metric Based on Sensitivity Analysis Applied to Electrical Repowering System
description Stability metrics are used to quantify a system’s ability to maintain equilibrium under disturbances. We did not identify the proposition of a stability metric using sensitivity analysis within the literature. This work proposes a system stability metric and its application to an electrical repowering system. The methodology for applying the proposed metric comprises: (i) system parameters sensitivity analysis and spider diagram construction, (ii) determining the array containing the line segments inclination angles of each spider diagram curve, and (iii) stability calculation using the array mean and maximum inclination value of a line segment. After simulating the model built for the electrical repowering system and applying the methodology, we obtain results regarding the sensitivity indices and stability values of system inputs relative to their outputs, considering the original system and with reduced parameters. Using the stability study, it was possible to determine different stability categories for the system parameters, which indicates the need for different analysis levels.
format article
author João R. B. Paiva
Alana S. Magalhães
Pedro H. F. Moraes
Júnio S. Bulhões
Wesley P. Calixto
author_facet João R. B. Paiva
Alana S. Magalhães
Pedro H. F. Moraes
Júnio S. Bulhões
Wesley P. Calixto
author_sort João R. B. Paiva
title Stability Metric Based on Sensitivity Analysis Applied to Electrical Repowering System
title_short Stability Metric Based on Sensitivity Analysis Applied to Electrical Repowering System
title_full Stability Metric Based on Sensitivity Analysis Applied to Electrical Repowering System
title_fullStr Stability Metric Based on Sensitivity Analysis Applied to Electrical Repowering System
title_full_unstemmed Stability Metric Based on Sensitivity Analysis Applied to Electrical Repowering System
title_sort stability metric based on sensitivity analysis applied to electrical repowering system
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/0ced7d5e0ba043eab58c36bc251de559
work_keys_str_mv AT joaorbpaiva stabilitymetricbasedonsensitivityanalysisappliedtoelectricalrepoweringsystem
AT alanasmagalhaes stabilitymetricbasedonsensitivityanalysisappliedtoelectricalrepoweringsystem
AT pedrohfmoraes stabilitymetricbasedonsensitivityanalysisappliedtoelectricalrepoweringsystem
AT juniosbulhoes stabilitymetricbasedonsensitivityanalysisappliedtoelectricalrepoweringsystem
AT wesleypcalixto stabilitymetricbasedonsensitivityanalysisappliedtoelectricalrepoweringsystem
_version_ 1718412268462407680