Intra-individual variation of upper airway measurements based on computed tomography.
The aims of this study were (1) to quantify the intra-individual variation in the upper airway measurements on supine computed tomography (CT) scans at two different time points; and (2) to identify the most stable parameters of the upper airway measurements over time. Ten subjects with paired CT da...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/0d8a4c638121451bba3959a93abee9f2 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:0d8a4c638121451bba3959a93abee9f2 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:0d8a4c638121451bba3959a93abee9f22021-12-02T20:06:01ZIntra-individual variation of upper airway measurements based on computed tomography.1932-620310.1371/journal.pone.0259739https://doaj.org/article/0d8a4c638121451bba3959a93abee9f22021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0259739https://doaj.org/toc/1932-6203The aims of this study were (1) to quantify the intra-individual variation in the upper airway measurements on supine computed tomography (CT) scans at two different time points; and (2) to identify the most stable parameters of the upper airway measurements over time. Ten subjects with paired CT datasets (3-6 months interval) were studied, using computer software to segment and measure the upper airway. The minimum cross-sectional area of the total airway and all its segments (velopharynx, oropharynx, tongue base, and epiglottis) generally had the largest variation, while the length of the total airway had the lowest variation. Sphericity was the only parameter that was stable over time (relative difference <15%), both in the total airway and each subregion. There was considerable intra-individual variation in CT measurements of the upper airway, with the same patient instruction protocol for image acquisitions. The length of the total airway, and the sphericity of the total upper airway and each segment were stable over time. Hence, such intra-individual variation should be taken into account when interpreting and comparing upper airway evaluation parameters on CT in order to quantify treatment results or disease progress.Ning ZhouJean-Pierre T F HoCornelis KlopRuud SchreursLudo F M BeenenGhizlane AarabJan de LangePublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 11, p e0259739 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Ning Zhou Jean-Pierre T F Ho Cornelis Klop Ruud Schreurs Ludo F M Beenen Ghizlane Aarab Jan de Lange Intra-individual variation of upper airway measurements based on computed tomography. |
description |
The aims of this study were (1) to quantify the intra-individual variation in the upper airway measurements on supine computed tomography (CT) scans at two different time points; and (2) to identify the most stable parameters of the upper airway measurements over time. Ten subjects with paired CT datasets (3-6 months interval) were studied, using computer software to segment and measure the upper airway. The minimum cross-sectional area of the total airway and all its segments (velopharynx, oropharynx, tongue base, and epiglottis) generally had the largest variation, while the length of the total airway had the lowest variation. Sphericity was the only parameter that was stable over time (relative difference <15%), both in the total airway and each subregion. There was considerable intra-individual variation in CT measurements of the upper airway, with the same patient instruction protocol for image acquisitions. The length of the total airway, and the sphericity of the total upper airway and each segment were stable over time. Hence, such intra-individual variation should be taken into account when interpreting and comparing upper airway evaluation parameters on CT in order to quantify treatment results or disease progress. |
format |
article |
author |
Ning Zhou Jean-Pierre T F Ho Cornelis Klop Ruud Schreurs Ludo F M Beenen Ghizlane Aarab Jan de Lange |
author_facet |
Ning Zhou Jean-Pierre T F Ho Cornelis Klop Ruud Schreurs Ludo F M Beenen Ghizlane Aarab Jan de Lange |
author_sort |
Ning Zhou |
title |
Intra-individual variation of upper airway measurements based on computed tomography. |
title_short |
Intra-individual variation of upper airway measurements based on computed tomography. |
title_full |
Intra-individual variation of upper airway measurements based on computed tomography. |
title_fullStr |
Intra-individual variation of upper airway measurements based on computed tomography. |
title_full_unstemmed |
Intra-individual variation of upper airway measurements based on computed tomography. |
title_sort |
intra-individual variation of upper airway measurements based on computed tomography. |
publisher |
Public Library of Science (PLoS) |
publishDate |
2021 |
url |
https://doaj.org/article/0d8a4c638121451bba3959a93abee9f2 |
work_keys_str_mv |
AT ningzhou intraindividualvariationofupperairwaymeasurementsbasedoncomputedtomography AT jeanpierretfho intraindividualvariationofupperairwaymeasurementsbasedoncomputedtomography AT cornelisklop intraindividualvariationofupperairwaymeasurementsbasedoncomputedtomography AT ruudschreurs intraindividualvariationofupperairwaymeasurementsbasedoncomputedtomography AT ludofmbeenen intraindividualvariationofupperairwaymeasurementsbasedoncomputedtomography AT ghizlaneaarab intraindividualvariationofupperairwaymeasurementsbasedoncomputedtomography AT jandelange intraindividualvariationofupperairwaymeasurementsbasedoncomputedtomography |
_version_ |
1718375404480233472 |