Effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity
Abstract Preanalytical quality control of blood samples is critical for tests of coagulation function and coagulation factor activity. Preanalytical storage time and temperature are the main variables. We investigated the effects of preanalytical frozen storage time and temperature on activated part...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/0dba97e8dae047ab9dcef84468a3a35c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:0dba97e8dae047ab9dcef84468a3a35c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:0dba97e8dae047ab9dcef84468a3a35c2021-12-02T11:52:28ZEffects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity10.1038/s41598-017-11777-x2045-2322https://doaj.org/article/0dba97e8dae047ab9dcef84468a3a35c2017-09-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-11777-xhttps://doaj.org/toc/2045-2322Abstract Preanalytical quality control of blood samples is critical for tests of coagulation function and coagulation factor activity. Preanalytical storage time and temperature are the main variables. We investigated the effects of preanalytical frozen storage time and temperature on activated partial thromboplastin time (APTT), fibrinogen (Fbg), prothrombin time (PT)/international normalized ratio (INR), thrombin time (TT), factor VIII activity (FVIII:C), and factor IX activity (FIX:C) in frozen plasma. Samples (n = 144) were randomly and equally divided into four groups (storage at −80 °C or −20 °C) and analysed by CS5100 or CA7000 coagulation analysers. Baseline values and results after storage for 15 days, 1 month, 3 months, 6 months, and 1 year were measured after thawing. Mean percent changes and scatter plots were used to determine clinically relevant differences. The stabilities of coagulation tests and coagulation factor activities measured by the CS5100 system were consistent with those measured by the CA7000 system. At −80 °C, assessment samples of PT/INR, Fbg, and TT can be safely stored for 1 year, APTT for 6 months, and FVIII:C and FIX:C for 1 month. At −20 °C, samples of Fbg and TT can be stored for 1 year, PT/INR and FIX:C for 1 month, and APTT and FVIII:C for 15 days.Ying ZhaoGuofang FengJie ZhangRenjie GongChangming CaiLimin FengNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-9 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Ying Zhao Guofang Feng Jie Zhang Renjie Gong Changming Cai Limin Feng Effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity |
description |
Abstract Preanalytical quality control of blood samples is critical for tests of coagulation function and coagulation factor activity. Preanalytical storage time and temperature are the main variables. We investigated the effects of preanalytical frozen storage time and temperature on activated partial thromboplastin time (APTT), fibrinogen (Fbg), prothrombin time (PT)/international normalized ratio (INR), thrombin time (TT), factor VIII activity (FVIII:C), and factor IX activity (FIX:C) in frozen plasma. Samples (n = 144) were randomly and equally divided into four groups (storage at −80 °C or −20 °C) and analysed by CS5100 or CA7000 coagulation analysers. Baseline values and results after storage for 15 days, 1 month, 3 months, 6 months, and 1 year were measured after thawing. Mean percent changes and scatter plots were used to determine clinically relevant differences. The stabilities of coagulation tests and coagulation factor activities measured by the CS5100 system were consistent with those measured by the CA7000 system. At −80 °C, assessment samples of PT/INR, Fbg, and TT can be safely stored for 1 year, APTT for 6 months, and FVIII:C and FIX:C for 1 month. At −20 °C, samples of Fbg and TT can be stored for 1 year, PT/INR and FIX:C for 1 month, and APTT and FVIII:C for 15 days. |
format |
article |
author |
Ying Zhao Guofang Feng Jie Zhang Renjie Gong Changming Cai Limin Feng |
author_facet |
Ying Zhao Guofang Feng Jie Zhang Renjie Gong Changming Cai Limin Feng |
author_sort |
Ying Zhao |
title |
Effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity |
title_short |
Effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity |
title_full |
Effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity |
title_fullStr |
Effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity |
title_full_unstemmed |
Effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity |
title_sort |
effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors viii and ix activity |
publisher |
Nature Portfolio |
publishDate |
2017 |
url |
https://doaj.org/article/0dba97e8dae047ab9dcef84468a3a35c |
work_keys_str_mv |
AT yingzhao effectsofpreanalyticalfrozenstoragetimeandtemperatureonscreeningcoagulationtestsandfactorsviiiandixactivity AT guofangfeng effectsofpreanalyticalfrozenstoragetimeandtemperatureonscreeningcoagulationtestsandfactorsviiiandixactivity AT jiezhang effectsofpreanalyticalfrozenstoragetimeandtemperatureonscreeningcoagulationtestsandfactorsviiiandixactivity AT renjiegong effectsofpreanalyticalfrozenstoragetimeandtemperatureonscreeningcoagulationtestsandfactorsviiiandixactivity AT changmingcai effectsofpreanalyticalfrozenstoragetimeandtemperatureonscreeningcoagulationtestsandfactorsviiiandixactivity AT liminfeng effectsofpreanalyticalfrozenstoragetimeandtemperatureonscreeningcoagulationtestsandfactorsviiiandixactivity |
_version_ |
1718395029696806912 |