Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?
Abstract Background The effect of right ventricular (RV) leads on tricuspid valve has been already raised concerns, especially in terms of prognostic implication. For such assessment, three-dimensional transthoracic echocardiography (3D-TTE) has been used previously but there was no data on the use...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
BMC
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/0e1cf10ee44f463b817b2b6919a67eaa |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:0e1cf10ee44f463b817b2b6919a67eaa |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:0e1cf10ee44f463b817b2b6919a67eaa2021-11-21T12:25:35ZPredictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?10.1186/s12947-021-00267-w1476-7120https://doaj.org/article/0e1cf10ee44f463b817b2b6919a67eaa2021-11-01T00:00:00Zhttps://doi.org/10.1186/s12947-021-00267-whttps://doaj.org/toc/1476-7120Abstract Background The effect of right ventricular (RV) leads on tricuspid valve has been already raised concerns, especially in terms of prognostic implication. For such assessment, three-dimensional transthoracic echocardiography (3D-TTE) has been used previously but there was no data on the use of post-procedural fluoroscopy in the literature. Methods We prospectively enrolled 59 patients who underwent clinically indicated placement of pacemaker or implantable cardioverter defibrillator (ICD). Vena contracta (VC) and tricuspid regurgitation (TR) severity were measured using two-dimensional transthoracic echocardiography (2D-TTE) at baseline. Follow up 3D-TTE was performed 6 months after device implantation to assess TR severity and RV lead location. Results Lead placement position in TV was defined in 51 cases.TR VC was increased after the lead placement, compared to the baseline study (VC: 3.86 ± 2.32 vs 3.18 ± 2.39; p = 0.005), with one grade worsening in TR in 25.4% of cases. The mean changes in VC levels were 1.14 ± 0.67 mm. Among all investigated parameters, VC changes were predicted based on lead placement position only in 3D-TTE (p < 0.001) while the other variables including fluoroscopy parameters were not informative. Conclusion The RV Lead location examined by 3D-TTE seems to be a valuable parameter to predict the changes in the severity of the tricuspid regurgitation. Fluoroscopy findings did not improve the predictive performance, at least in short term follow up.Hoorak PoorzandMohammad TayyebiSara HosseiniAlireza Heidari BakavoliFaeze KeihanianLida JarahiAli HamadanchiBMCarticlePacemakerEchocardiographyThree-dimensional echocardiographyTricuspid regurgitationRight ventricleDiseases of the circulatory (Cardiovascular) systemRC666-701ENCardiovascular Ultrasound, Vol 19, Iss 1, Pp 1-9 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Pacemaker Echocardiography Three-dimensional echocardiography Tricuspid regurgitation Right ventricle Diseases of the circulatory (Cardiovascular) system RC666-701 |
spellingShingle |
Pacemaker Echocardiography Three-dimensional echocardiography Tricuspid regurgitation Right ventricle Diseases of the circulatory (Cardiovascular) system RC666-701 Hoorak Poorzand Mohammad Tayyebi Sara Hosseini Alireza Heidari Bakavoli Faeze Keihanian Lida Jarahi Ali Hamadanchi Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography? |
description |
Abstract Background The effect of right ventricular (RV) leads on tricuspid valve has been already raised concerns, especially in terms of prognostic implication. For such assessment, three-dimensional transthoracic echocardiography (3D-TTE) has been used previously but there was no data on the use of post-procedural fluoroscopy in the literature. Methods We prospectively enrolled 59 patients who underwent clinically indicated placement of pacemaker or implantable cardioverter defibrillator (ICD). Vena contracta (VC) and tricuspid regurgitation (TR) severity were measured using two-dimensional transthoracic echocardiography (2D-TTE) at baseline. Follow up 3D-TTE was performed 6 months after device implantation to assess TR severity and RV lead location. Results Lead placement position in TV was defined in 51 cases.TR VC was increased after the lead placement, compared to the baseline study (VC: 3.86 ± 2.32 vs 3.18 ± 2.39; p = 0.005), with one grade worsening in TR in 25.4% of cases. The mean changes in VC levels were 1.14 ± 0.67 mm. Among all investigated parameters, VC changes were predicted based on lead placement position only in 3D-TTE (p < 0.001) while the other variables including fluoroscopy parameters were not informative. Conclusion The RV Lead location examined by 3D-TTE seems to be a valuable parameter to predict the changes in the severity of the tricuspid regurgitation. Fluoroscopy findings did not improve the predictive performance, at least in short term follow up. |
format |
article |
author |
Hoorak Poorzand Mohammad Tayyebi Sara Hosseini Alireza Heidari Bakavoli Faeze Keihanian Lida Jarahi Ali Hamadanchi |
author_facet |
Hoorak Poorzand Mohammad Tayyebi Sara Hosseini Alireza Heidari Bakavoli Faeze Keihanian Lida Jarahi Ali Hamadanchi |
author_sort |
Hoorak Poorzand |
title |
Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography? |
title_short |
Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography? |
title_full |
Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography? |
title_fullStr |
Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography? |
title_full_unstemmed |
Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography? |
title_sort |
predictors of worsening tr severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography? |
publisher |
BMC |
publishDate |
2021 |
url |
https://doaj.org/article/0e1cf10ee44f463b817b2b6919a67eaa |
work_keys_str_mv |
AT hoorakpoorzand predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography AT mohammadtayyebi predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography AT sarahosseini predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography AT alirezaheidaribakavoli predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography AT faezekeihanian predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography AT lidajarahi predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography AT alihamadanchi predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography |
_version_ |
1718418986412015616 |