Breakdown Voltage of Transformer Oil Containing Cellulose Particle Contamination With and Without Bridge Formation Under Lightning Impulse Stress

This study investigates the effect of cellulose bridge formation on insulating oil. Such effect influences the breakdown voltage and strength of mineral oil (MO) under standard lightning impulse (LI) voltage. A cylindrical test vessel fitted with spherical–spherical electrodes with a 2 mm...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Sarizan Bin Saaidon, Mohd Aizam Talib, Mohamad Nur Khairul Hafizi Rohani, Nor Asiah Muhamad, Mohamad Kamarol Mohd Jamil
Formato: article
Lenguaje:EN
Publicado: IEEE 2021
Materias:
Acceso en línea:https://doaj.org/article/0e63c7954257466f8896f742bb023ba4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:0e63c7954257466f8896f742bb023ba4
record_format dspace
spelling oai:doaj.org-article:0e63c7954257466f8896f742bb023ba42021-11-18T00:10:00ZBreakdown Voltage of Transformer Oil Containing Cellulose Particle Contamination With and Without Bridge Formation Under Lightning Impulse Stress2169-353610.1109/ACCESS.2021.3124098https://doaj.org/article/0e63c7954257466f8896f742bb023ba42021-01-01T00:00:00Zhttps://ieeexplore.ieee.org/document/9592780/https://doaj.org/toc/2169-3536This study investigates the effect of cellulose bridge formation on insulating oil. Such effect influences the breakdown voltage and strength of mineral oil (MO) under standard lightning impulse (LI) voltage. A cylindrical test vessel fitted with spherical&#x2013;spherical electrodes with a 2 mm gap distance between them was used to generate a quasi-uniform field and observe bridge formation between the gaps. A positive LI waveform (1.2/<inline-formula> <tex-math notation="LaTeX">$50~\mu \text{s}$ </tex-math></inline-formula>) generated by an impulse generator was applied during the breakdown tests. The rising-voltage method was used to measure the breakdown voltage in accordance with the IEC 60897 standard test method. Weibull cumulative breakdown probability was applied to present the breakdown results statistically, and the outcome was compared with clean oil (CO). Commercial cellulose microcrystalline particles were dispersed into the transformer oil to act as bridge. The concentrations of the samples were 0.004&#x0025;, 0.008&#x0025; and 0.012&#x0025; by weight. The breakdown test results showed that the cellulosic particles reduced the LI breakdown voltage (LIBV) of MO by up to 10&#x0025;. The influence of cellulose particles on LIBV was also more prominent during bridge formation, with a further reduction of 14&#x0025;. Evidently, the presence of the cellulose bridge exerted a detrimental effect on the breakdown voltage of MO under LI stress, yielding a reduction of 24&#x0025; and 27&#x0025; at 0.004 wt&#x0025; and 0.012 wt&#x0025;, respectively. Finite element analysis also indicated that the electrical field strength of cellulosic particle contamination of 0.004 wt&#x0025; and 0.012 wt&#x0025; without a bridge skeleton exceeded the critical electric field strength of CO by 20&#x0025; and 61&#x0025;, respectively. The presence of cellulosic contamination at any concentration, i.e. either with or without a bridge structure, clearly decreased the breakdown strength of transformer oil. However, the breakdown is not occurred instantaneously. The LI breakdown was initiated and established only at a certain impulse stress level, when the electric field strength along the bridge lines exceeded the critical electric field strength of the oil. Thus, this finding potentially contributes to the formulation of guidelines for condition assessment and contamination monitoring to minimise common issues in power transformer failures that are attributable to the insulation system, and consequently, achieve optimum transformer insulation integrity.Sarizan Bin SaaidonMohd Aizam TalibMohamad Nur Khairul Hafizi RohaniNor Asiah MuhamadMohamad Kamarol Mohd JamilIEEEarticleQuasi-uniform fieldcellulose particle bridgingbreakdown voltagelightning impulse stressElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENIEEE Access, Vol 9, Pp 147994-148003 (2021)
institution DOAJ
collection DOAJ
language EN
topic Quasi-uniform field
cellulose particle bridging
breakdown voltage
lightning impulse stress
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle Quasi-uniform field
cellulose particle bridging
breakdown voltage
lightning impulse stress
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Sarizan Bin Saaidon
Mohd Aizam Talib
Mohamad Nur Khairul Hafizi Rohani
Nor Asiah Muhamad
Mohamad Kamarol Mohd Jamil
Breakdown Voltage of Transformer Oil Containing Cellulose Particle Contamination With and Without Bridge Formation Under Lightning Impulse Stress
description This study investigates the effect of cellulose bridge formation on insulating oil. Such effect influences the breakdown voltage and strength of mineral oil (MO) under standard lightning impulse (LI) voltage. A cylindrical test vessel fitted with spherical&#x2013;spherical electrodes with a 2 mm gap distance between them was used to generate a quasi-uniform field and observe bridge formation between the gaps. A positive LI waveform (1.2/<inline-formula> <tex-math notation="LaTeX">$50~\mu \text{s}$ </tex-math></inline-formula>) generated by an impulse generator was applied during the breakdown tests. The rising-voltage method was used to measure the breakdown voltage in accordance with the IEC 60897 standard test method. Weibull cumulative breakdown probability was applied to present the breakdown results statistically, and the outcome was compared with clean oil (CO). Commercial cellulose microcrystalline particles were dispersed into the transformer oil to act as bridge. The concentrations of the samples were 0.004&#x0025;, 0.008&#x0025; and 0.012&#x0025; by weight. The breakdown test results showed that the cellulosic particles reduced the LI breakdown voltage (LIBV) of MO by up to 10&#x0025;. The influence of cellulose particles on LIBV was also more prominent during bridge formation, with a further reduction of 14&#x0025;. Evidently, the presence of the cellulose bridge exerted a detrimental effect on the breakdown voltage of MO under LI stress, yielding a reduction of 24&#x0025; and 27&#x0025; at 0.004 wt&#x0025; and 0.012 wt&#x0025;, respectively. Finite element analysis also indicated that the electrical field strength of cellulosic particle contamination of 0.004 wt&#x0025; and 0.012 wt&#x0025; without a bridge skeleton exceeded the critical electric field strength of CO by 20&#x0025; and 61&#x0025;, respectively. The presence of cellulosic contamination at any concentration, i.e. either with or without a bridge structure, clearly decreased the breakdown strength of transformer oil. However, the breakdown is not occurred instantaneously. The LI breakdown was initiated and established only at a certain impulse stress level, when the electric field strength along the bridge lines exceeded the critical electric field strength of the oil. Thus, this finding potentially contributes to the formulation of guidelines for condition assessment and contamination monitoring to minimise common issues in power transformer failures that are attributable to the insulation system, and consequently, achieve optimum transformer insulation integrity.
format article
author Sarizan Bin Saaidon
Mohd Aizam Talib
Mohamad Nur Khairul Hafizi Rohani
Nor Asiah Muhamad
Mohamad Kamarol Mohd Jamil
author_facet Sarizan Bin Saaidon
Mohd Aizam Talib
Mohamad Nur Khairul Hafizi Rohani
Nor Asiah Muhamad
Mohamad Kamarol Mohd Jamil
author_sort Sarizan Bin Saaidon
title Breakdown Voltage of Transformer Oil Containing Cellulose Particle Contamination With and Without Bridge Formation Under Lightning Impulse Stress
title_short Breakdown Voltage of Transformer Oil Containing Cellulose Particle Contamination With and Without Bridge Formation Under Lightning Impulse Stress
title_full Breakdown Voltage of Transformer Oil Containing Cellulose Particle Contamination With and Without Bridge Formation Under Lightning Impulse Stress
title_fullStr Breakdown Voltage of Transformer Oil Containing Cellulose Particle Contamination With and Without Bridge Formation Under Lightning Impulse Stress
title_full_unstemmed Breakdown Voltage of Transformer Oil Containing Cellulose Particle Contamination With and Without Bridge Formation Under Lightning Impulse Stress
title_sort breakdown voltage of transformer oil containing cellulose particle contamination with and without bridge formation under lightning impulse stress
publisher IEEE
publishDate 2021
url https://doaj.org/article/0e63c7954257466f8896f742bb023ba4
work_keys_str_mv AT sarizanbinsaaidon breakdownvoltageoftransformeroilcontainingcelluloseparticlecontaminationwithandwithoutbridgeformationunderlightningimpulsestress
AT mohdaizamtalib breakdownvoltageoftransformeroilcontainingcelluloseparticlecontaminationwithandwithoutbridgeformationunderlightningimpulsestress
AT mohamadnurkhairulhafizirohani breakdownvoltageoftransformeroilcontainingcelluloseparticlecontaminationwithandwithoutbridgeformationunderlightningimpulsestress
AT norasiahmuhamad breakdownvoltageoftransformeroilcontainingcelluloseparticlecontaminationwithandwithoutbridgeformationunderlightningimpulsestress
AT mohamadkamarolmohdjamil breakdownvoltageoftransformeroilcontainingcelluloseparticlecontaminationwithandwithoutbridgeformationunderlightningimpulsestress
_version_ 1718425206493544448