“Ménage à Trois”: Use of 2 Supplemental Buddy Wires During TAVINovel Teaching Point

We herein present clinical images illustrating a transcatheter aortic valve implantation within an extremely calcified aortic valve, which posed considerable difficulty in crossing the aortic annulus. To gain maximum support, we used 2 buddy wires to allow a balloon predilation and then a successful...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Vassili Panagides, MD, Siamak Mohammadi, MD, Josep Rodés-Cabau, MD, Jean-Michel Paradis, MD
Formato: article
Lenguaje:EN
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://doaj.org/article/0ea70634eec44b84b72a25efbf812ffb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:0ea70634eec44b84b72a25efbf812ffb
record_format dspace
spelling oai:doaj.org-article:0ea70634eec44b84b72a25efbf812ffb2021-11-30T04:17:26Z“Ménage à Trois”: Use of 2 Supplemental Buddy Wires During TAVINovel Teaching Point2589-790X10.1016/j.cjco.2021.06.016https://doaj.org/article/0ea70634eec44b84b72a25efbf812ffb2021-11-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2589790X21001815https://doaj.org/toc/2589-790XWe herein present clinical images illustrating a transcatheter aortic valve implantation within an extremely calcified aortic valve, which posed considerable difficulty in crossing the aortic annulus. To gain maximum support, we used 2 buddy wires to allow a balloon predilation and then a successful crossing of the transcatheter heart valve. This technique provides additional support for those performing this procedure and may be included in the armamentarium of transcatheter aortic valve specialists. Résumé: Nous présentons ici des images cliniques illustrant un remplacement valvulaire aortique percutané au sein d'une valve aortique native extrêmement calcifiée, ce qui rendait très difficile la traversée de l’anneau aortique. Pour obtenir un soutien maximal, nous avons utilisé 2 fils-guides pour permettre une prédilatation par ballonnet, puis un passage réussi de la valve percutanée. Cette technique apporte un soutien supplémentaire à ceux qui pratiquent cette intervention et peut être ajoutée à l’arsenal thérapeutique des spécialistes de l’implantation de valves aortiques percutanées.Vassili Panagides, MDSiamak Mohammadi, MDJosep Rodés-Cabau, MDJean-Michel Paradis, MDElsevierarticleDiseases of the circulatory (Cardiovascular) systemRC666-701ENCJC Open, Vol 3, Iss 11, Pp 1403-1405 (2021)
institution DOAJ
collection DOAJ
language EN
topic Diseases of the circulatory (Cardiovascular) system
RC666-701
spellingShingle Diseases of the circulatory (Cardiovascular) system
RC666-701
Vassili Panagides, MD
Siamak Mohammadi, MD
Josep Rodés-Cabau, MD
Jean-Michel Paradis, MD
“Ménage à Trois”: Use of 2 Supplemental Buddy Wires During TAVINovel Teaching Point
description We herein present clinical images illustrating a transcatheter aortic valve implantation within an extremely calcified aortic valve, which posed considerable difficulty in crossing the aortic annulus. To gain maximum support, we used 2 buddy wires to allow a balloon predilation and then a successful crossing of the transcatheter heart valve. This technique provides additional support for those performing this procedure and may be included in the armamentarium of transcatheter aortic valve specialists. Résumé: Nous présentons ici des images cliniques illustrant un remplacement valvulaire aortique percutané au sein d'une valve aortique native extrêmement calcifiée, ce qui rendait très difficile la traversée de l’anneau aortique. Pour obtenir un soutien maximal, nous avons utilisé 2 fils-guides pour permettre une prédilatation par ballonnet, puis un passage réussi de la valve percutanée. Cette technique apporte un soutien supplémentaire à ceux qui pratiquent cette intervention et peut être ajoutée à l’arsenal thérapeutique des spécialistes de l’implantation de valves aortiques percutanées.
format article
author Vassili Panagides, MD
Siamak Mohammadi, MD
Josep Rodés-Cabau, MD
Jean-Michel Paradis, MD
author_facet Vassili Panagides, MD
Siamak Mohammadi, MD
Josep Rodés-Cabau, MD
Jean-Michel Paradis, MD
author_sort Vassili Panagides, MD
title “Ménage à Trois”: Use of 2 Supplemental Buddy Wires During TAVINovel Teaching Point
title_short “Ménage à Trois”: Use of 2 Supplemental Buddy Wires During TAVINovel Teaching Point
title_full “Ménage à Trois”: Use of 2 Supplemental Buddy Wires During TAVINovel Teaching Point
title_fullStr “Ménage à Trois”: Use of 2 Supplemental Buddy Wires During TAVINovel Teaching Point
title_full_unstemmed “Ménage à Trois”: Use of 2 Supplemental Buddy Wires During TAVINovel Teaching Point
title_sort “ménage à trois”: use of 2 supplemental buddy wires during tavinovel teaching point
publisher Elsevier
publishDate 2021
url https://doaj.org/article/0ea70634eec44b84b72a25efbf812ffb
work_keys_str_mv AT vassilipanagidesmd menageatroisuseof2supplementalbuddywiresduringtavinovelteachingpoint
AT siamakmohammadimd menageatroisuseof2supplementalbuddywiresduringtavinovelteachingpoint
AT joseprodescabaumd menageatroisuseof2supplementalbuddywiresduringtavinovelteachingpoint
AT jeanmichelparadismd menageatroisuseof2supplementalbuddywiresduringtavinovelteachingpoint
_version_ 1718406726272679936