The simply modified intrascleral fixation using round flange (SMURF) technique for intrascleral intraocular lens fixation

Abstract We describe a simply modified intrascleral fixation using round flange (SMURF) technique and report the clinical outcomes of the surgery. Forty-one eyes of 41 consecutive patients, with intraocular lens (IOL) dislocation, crystalline lens subluxation, and zonular weakness, who underwent sur...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Soa Kim, Jee Taek Kim
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/0f351d5c936745d5802f09066dad801e
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:0f351d5c936745d5802f09066dad801e
record_format dspace
spelling oai:doaj.org-article:0f351d5c936745d5802f09066dad801e2021-12-02T12:11:34ZThe simply modified intrascleral fixation using round flange (SMURF) technique for intrascleral intraocular lens fixation10.1038/s41598-021-81924-y2045-2322https://doaj.org/article/0f351d5c936745d5802f09066dad801e2021-02-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-81924-yhttps://doaj.org/toc/2045-2322Abstract We describe a simply modified intrascleral fixation using round flange (SMURF) technique and report the clinical outcomes of the surgery. Forty-one eyes of 41 consecutive patients, with intraocular lens (IOL) dislocation, crystalline lens subluxation, and zonular weakness, who underwent surgery using the SMURF technique were included. The modified technique included the use of a conventional 27-gauge needle, a non-bent needle, oblique sclerotomy, direct threading of the leading haptic, and simple placement of the following haptic. IOLs were successfully placed and showed good centring. There were no cases of wound leakage or hypotony during the early postoperative period. Postoperative complications included vitreous haemorrhage in one eye (2.4%), intraocular pressure elevation in one eye (2.4%), and iris capture in six eyes (14.6%). There were no cases of postoperative retinal detachment, cystoid macular oedema, endophthalmitis, or IOL dislocation during the follow-up period. We proposed a few modifications in the intrascleral flanged technique for IOL fixation. The modified technique is a simple, easy, and minimally invasive procedure for successful IOL intrascleral fixation.Soa KimJee Taek KimNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Soa Kim
Jee Taek Kim
The simply modified intrascleral fixation using round flange (SMURF) technique for intrascleral intraocular lens fixation
description Abstract We describe a simply modified intrascleral fixation using round flange (SMURF) technique and report the clinical outcomes of the surgery. Forty-one eyes of 41 consecutive patients, with intraocular lens (IOL) dislocation, crystalline lens subluxation, and zonular weakness, who underwent surgery using the SMURF technique were included. The modified technique included the use of a conventional 27-gauge needle, a non-bent needle, oblique sclerotomy, direct threading of the leading haptic, and simple placement of the following haptic. IOLs were successfully placed and showed good centring. There were no cases of wound leakage or hypotony during the early postoperative period. Postoperative complications included vitreous haemorrhage in one eye (2.4%), intraocular pressure elevation in one eye (2.4%), and iris capture in six eyes (14.6%). There were no cases of postoperative retinal detachment, cystoid macular oedema, endophthalmitis, or IOL dislocation during the follow-up period. We proposed a few modifications in the intrascleral flanged technique for IOL fixation. The modified technique is a simple, easy, and minimally invasive procedure for successful IOL intrascleral fixation.
format article
author Soa Kim
Jee Taek Kim
author_facet Soa Kim
Jee Taek Kim
author_sort Soa Kim
title The simply modified intrascleral fixation using round flange (SMURF) technique for intrascleral intraocular lens fixation
title_short The simply modified intrascleral fixation using round flange (SMURF) technique for intrascleral intraocular lens fixation
title_full The simply modified intrascleral fixation using round flange (SMURF) technique for intrascleral intraocular lens fixation
title_fullStr The simply modified intrascleral fixation using round flange (SMURF) technique for intrascleral intraocular lens fixation
title_full_unstemmed The simply modified intrascleral fixation using round flange (SMURF) technique for intrascleral intraocular lens fixation
title_sort simply modified intrascleral fixation using round flange (smurf) technique for intrascleral intraocular lens fixation
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/0f351d5c936745d5802f09066dad801e
work_keys_str_mv AT soakim thesimplymodifiedintrascleralfixationusingroundflangesmurftechniqueforintrascleralintraocularlensfixation
AT jeetaekkim thesimplymodifiedintrascleralfixationusingroundflangesmurftechniqueforintrascleralintraocularlensfixation
AT soakim simplymodifiedintrascleralfixationusingroundflangesmurftechniqueforintrascleralintraocularlensfixation
AT jeetaekkim simplymodifiedintrascleralfixationusingroundflangesmurftechniqueforintrascleralintraocularlensfixation
_version_ 1718394613295742976