Selective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients
Mohammed K El Mallah1, Molly M Walsh2, Sandra S Stinnett2, Sanjay G Asrani21Ocala Eye, Ocala, Florida, USA; 2Duke University Eye Center, Durham, North Carolina, USAPurpose: To evaluate the effect of selective laser trabeculoplasty (SLT) in normal tension glaucoma (NTG) patients.Patients and methods:...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2010
|
Materias: | |
Acceso en línea: | https://doaj.org/article/0f7f08a821834a66834b43f42c62e893 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:0f7f08a821834a66834b43f42c62e893 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:0f7f08a821834a66834b43f42c62e8932021-12-02T06:23:29ZSelective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients1177-54671177-5483https://doaj.org/article/0f7f08a821834a66834b43f42c62e8932010-07-01T00:00:00Zhttp://www.dovepress.com/selective-laser-trabeculoplasty-reduces-mean-iop-and-iop-variation-in--a4954https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Mohammed K El Mallah1, Molly M Walsh2, Sandra S Stinnett2, Sanjay G Asrani21Ocala Eye, Ocala, Florida, USA; 2Duke University Eye Center, Durham, North Carolina, USAPurpose: To evaluate the effect of selective laser trabeculoplasty (SLT) in normal tension glaucoma (NTG) patients.Patients and methods: A retrospective review was performed of NTG patients who had undergone SLT at the Duke University Eye Center between 12/2002 and 7/2005. For each eye of each patient at pre-laser and post-laser time points, the IOP measurements were summarized by mean, standard deviation, and range. Then for each of these descriptive statistics, the differences between pre-laser and post-laser values were obtained. Statistical analysis was performed using a random effects model. Main outcome measures: difference in mean IOP, standard deviation of IOP, and range of IOP.Results: Thirty-one eyes of 18 patients were included for analysis. The average of the mean ­pre-operative IOP measurements was 14.3 ± 2.6 mmHg compared to 12.2 ± 1.7 mmHg (P < 0.001) post-operatively. The mean pre-operative standard deviation was 1.9 ± 0.9 mmHg compared to 1.0 ± 0.6 mmHg (P = 0.002) post-operatively while the mean IOP range prior to treatment was 4.5 ± 2.5 mmHg compared to 2.5 ± 1.9 mmHg (P = 0.017) after treatment.Conclusion: In this pilot study, SLT was found to lower mean IOP and intervisit IOP ­variation in NTG patients. Given the importance of IOP variation and its association with glaucoma ­progression, measurement of IOP variation following treatment with SLT may be considered.Keywords: SLT, NTG, laser, glaucoma Mohammed K El MallahMolly M WalshSandra S Stinnettet alDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2010, Iss default, Pp 889-893 (2010) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Mohammed K El Mallah Molly M Walsh Sandra S Stinnett et al Selective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients |
description |
Mohammed K El Mallah1, Molly M Walsh2, Sandra S Stinnett2, Sanjay G Asrani21Ocala Eye, Ocala, Florida, USA; 2Duke University Eye Center, Durham, North Carolina, USAPurpose: To evaluate the effect of selective laser trabeculoplasty (SLT) in normal tension glaucoma (NTG) patients.Patients and methods: A retrospective review was performed of NTG patients who had undergone SLT at the Duke University Eye Center between 12/2002 and 7/2005. For each eye of each patient at pre-laser and post-laser time points, the IOP measurements were summarized by mean, standard deviation, and range. Then for each of these descriptive statistics, the differences between pre-laser and post-laser values were obtained. Statistical analysis was performed using a random effects model. Main outcome measures: difference in mean IOP, standard deviation of IOP, and range of IOP.Results: Thirty-one eyes of 18 patients were included for analysis. The average of the mean ­pre-operative IOP measurements was 14.3 ± 2.6 mmHg compared to 12.2 ± 1.7 mmHg (P < 0.001) post-operatively. The mean pre-operative standard deviation was 1.9 ± 0.9 mmHg compared to 1.0 ± 0.6 mmHg (P = 0.002) post-operatively while the mean IOP range prior to treatment was 4.5 ± 2.5 mmHg compared to 2.5 ± 1.9 mmHg (P = 0.017) after treatment.Conclusion: In this pilot study, SLT was found to lower mean IOP and intervisit IOP ­variation in NTG patients. Given the importance of IOP variation and its association with glaucoma ­progression, measurement of IOP variation following treatment with SLT may be considered.Keywords: SLT, NTG, laser, glaucoma |
format |
article |
author |
Mohammed K El Mallah Molly M Walsh Sandra S Stinnett et al |
author_facet |
Mohammed K El Mallah Molly M Walsh Sandra S Stinnett et al |
author_sort |
Mohammed K El Mallah |
title |
Selective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients |
title_short |
Selective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients |
title_full |
Selective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients |
title_fullStr |
Selective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients |
title_full_unstemmed |
Selective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients |
title_sort |
selective laser trabeculoplasty reduces mean iop and iop variation in normal tension glaucoma patients |
publisher |
Dove Medical Press |
publishDate |
2010 |
url |
https://doaj.org/article/0f7f08a821834a66834b43f42c62e893 |
work_keys_str_mv |
AT mohammedkelmallah selectivelasertrabeculoplastyreducesmeaniopandiopvariationinnormaltensionglaucomapatients AT mollymwalsh selectivelasertrabeculoplastyreducesmeaniopandiopvariationinnormaltensionglaucomapatients AT sandrasstinnett selectivelasertrabeculoplastyreducesmeaniopandiopvariationinnormaltensionglaucomapatients AT etal selectivelasertrabeculoplastyreducesmeaniopandiopvariationinnormaltensionglaucomapatients |
_version_ |
1718399916680675328 |