Comparison of nonlinear static analysis of Iranian standard 2800 with ASCE/SEI 41-13 in intermediate MRF RC buildings
One of the simplified methods, which is progressing and completing every day, is a nonlinear static analysis that can directly evaluate the performance of a structure in any limit state and provide information about the nonlinear behavior of the structure, and it also does not have the complexity of...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | FA |
Publicado: |
Iranian Society of Structrual Engineering (ISSE)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/100ee41490e24eec8965d4c675052774 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:100ee41490e24eec8965d4c675052774 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:100ee41490e24eec8965d4c6750527742021-11-08T15:54:19ZComparison of nonlinear static analysis of Iranian standard 2800 with ASCE/SEI 41-13 in intermediate MRF RC buildings2476-39772538-261610.22065/jsce.2019.148234.1679https://doaj.org/article/100ee41490e24eec8965d4c6750527742021-03-01T00:00:00Zhttps://www.jsce.ir/article_85709_8c81d5b32235ca181646254ecf569416.pdfhttps://doaj.org/toc/2476-3977https://doaj.org/toc/2538-2616One of the simplified methods, which is progressing and completing every day, is a nonlinear static analysis that can directly evaluate the performance of a structure in any limit state and provide information about the nonlinear behavior of the structure, and it also does not have the complexity of nonlinear dynamic analysis. In this study, the structural responses of nonlinear static procedure (NSP) based on standard 2800 were compared with ASCE 41-13 code and displacement -based adaptive pushover (DAP) method in three models of reinforced concrete structures including the 3, 7 and 10 story with medium ductility. In order to study the accuracy of nonlinear static analysis and seismic behavior of structures, nonlinear time history analysis (NTHA) which is the most accurate method in seismic assessment of structures was conducted.The results show that in 3 and 10 story the NSP according to standard 2800 with forces distribution obtained from the spectral dynamical analysis is more accurate than other NSPs in evaluating of story drifts ratio and maximum displacement along the height of buildings. In 7 story, displacement -based adaptive pushover (DAP) method can be estimated story drift ratio more precisely. In 3 and 10 story, the NSP based on 2800 with forces distribution obtained from the spectral dynamical analysis, can estimate the mean story drifts with a lower percentage error. According to the results, in each three model the uniform distribution of nonlinear static procedure (NSP) based on standard 2800 estimates the story drifts with less accuracy and high error. As a suggestion, nonlinear static analysis based on uniform distribution can be eliminated from the standard 2800.Bahador Habibi PourZareعبدالحسین فلاحیArjang SadeghiIranian Society of Structrual Engineering (ISSE)articlenonlinear static analysisnonlinear dynamic analysisadaptive pushovernonlinear time history analysisreinforced concrete structureBridge engineeringTG1-470Building constructionTH1-9745FAJournal of Structural and Construction Engineering, Vol 8, Iss 1, Pp 193-219 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
FA |
topic |
nonlinear static analysis nonlinear dynamic analysis adaptive pushover nonlinear time history analysis reinforced concrete structure Bridge engineering TG1-470 Building construction TH1-9745 |
spellingShingle |
nonlinear static analysis nonlinear dynamic analysis adaptive pushover nonlinear time history analysis reinforced concrete structure Bridge engineering TG1-470 Building construction TH1-9745 Bahador Habibi PourZare عبدالحسین فلاحی Arjang Sadeghi Comparison of nonlinear static analysis of Iranian standard 2800 with ASCE/SEI 41-13 in intermediate MRF RC buildings |
description |
One of the simplified methods, which is progressing and completing every day, is a nonlinear static analysis that can directly evaluate the performance of a structure in any limit state and provide information about the nonlinear behavior of the structure, and it also does not have the complexity of nonlinear dynamic analysis. In this study, the structural responses of nonlinear static procedure (NSP) based on standard 2800 were compared with ASCE 41-13 code and displacement -based adaptive pushover (DAP) method in three models of reinforced concrete structures including the 3, 7 and 10 story with medium ductility. In order to study the accuracy of nonlinear static analysis and seismic behavior of structures, nonlinear time history analysis (NTHA) which is the most accurate method in seismic assessment of structures was conducted.The results show that in 3 and 10 story the NSP according to standard 2800 with forces distribution obtained from the spectral dynamical analysis is more accurate than other NSPs in evaluating of story drifts ratio and maximum displacement along the height of buildings. In 7 story, displacement -based adaptive pushover (DAP) method can be estimated story drift ratio more precisely. In 3 and 10 story, the NSP based on 2800 with forces distribution obtained from the spectral dynamical analysis, can estimate the mean story drifts with a lower percentage error. According to the results, in each three model the uniform distribution of nonlinear static procedure (NSP) based on standard 2800 estimates the story drifts with less accuracy and high error. As a suggestion, nonlinear static analysis based on uniform distribution can be eliminated from the standard 2800. |
format |
article |
author |
Bahador Habibi PourZare عبدالحسین فلاحی Arjang Sadeghi |
author_facet |
Bahador Habibi PourZare عبدالحسین فلاحی Arjang Sadeghi |
author_sort |
Bahador Habibi PourZare |
title |
Comparison of nonlinear static analysis of Iranian standard 2800 with ASCE/SEI 41-13 in intermediate MRF RC buildings |
title_short |
Comparison of nonlinear static analysis of Iranian standard 2800 with ASCE/SEI 41-13 in intermediate MRF RC buildings |
title_full |
Comparison of nonlinear static analysis of Iranian standard 2800 with ASCE/SEI 41-13 in intermediate MRF RC buildings |
title_fullStr |
Comparison of nonlinear static analysis of Iranian standard 2800 with ASCE/SEI 41-13 in intermediate MRF RC buildings |
title_full_unstemmed |
Comparison of nonlinear static analysis of Iranian standard 2800 with ASCE/SEI 41-13 in intermediate MRF RC buildings |
title_sort |
comparison of nonlinear static analysis of iranian standard 2800 with asce/sei 41-13 in intermediate mrf rc buildings |
publisher |
Iranian Society of Structrual Engineering (ISSE) |
publishDate |
2021 |
url |
https://doaj.org/article/100ee41490e24eec8965d4c675052774 |
work_keys_str_mv |
AT bahadorhabibipourzare comparisonofnonlinearstaticanalysisofiranianstandard2800withascesei4113inintermediatemrfrcbuildings AT ʿbdạlḥsynflạḥy comparisonofnonlinearstaticanalysisofiranianstandard2800withascesei4113inintermediatemrfrcbuildings AT arjangsadeghi comparisonofnonlinearstaticanalysisofiranianstandard2800withascesei4113inintermediatemrfrcbuildings |
_version_ |
1718441544513486848 |