PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE

Purpose. Investigations of the characteristics of pressure waves presuppose the registration of the total profile of the pressure wave at a given point in space. For these purposes, various types of «pressure to the electrical signal» transmitters (sensors) are used. Most of the common sensors are u...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: V. G. Zhekul, O. P. Smirnov, E. I. Taftaj, O. V. Khvoshchan, I. S. Shvets
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2017
Materias:
Acceso en línea:https://doaj.org/article/103ecb176d4a4f3eb734e2852cec7e89
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:103ecb176d4a4f3eb734e2852cec7e89
record_format dspace
spelling oai:doaj.org-article:103ecb176d4a4f3eb734e2852cec7e892021-12-02T16:12:21ZPIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE10.20998/2074-272X.2017.5.092074-272X2309-3404https://doaj.org/article/103ecb176d4a4f3eb734e2852cec7e892017-10-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2017.5.09/107219https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. Investigations of the characteristics of pressure waves presuppose the registration of the total profile of the pressure wave at a given point in space. For these purposes, various types of «pressure to the electrical signal» transmitters (sensors) are used. Most of the common sensors are unsuitable for measuring the pulse pressure in a closed water volume at high hydrostatic pressures, in particular to study the effect of a powerful high-voltage pulse discharge on increasing the inflow of minerals and drinking water in wells. The purpose of the work was to develop antijamming piezoelectric waveguide sensor for measuring pulse pressure at a close distance from a high-voltage discharge channel in a closed volume of a liquid. Methodology. We have applied the calibration method as used as a secondary standard, the theory of electrical circuits. Results. We have selected the design and the circuit solution of the waveguide pressure sensor. We have developed a waveguide pulse-pressure sensor DTX-1 with a measuring loop. This sensor makes it possible to study the spectral characteristics of pressure waves of high-voltage pulse discharge in closed volumes of liquid at a hydrostatic pressure of up to 20 MPa and a temperature of up to 80 °C. The sensor can be used to study pressure waves with a maximum amplitude value of up to 150 MPa and duration of up to 80 µs. According to the results of the calibration, the sensitivity of the developed sensor DTX-1 with a measuring loop is 0.0346 V/MPa. Originality. We have further developed the theory of designing the waveguide piezoelectric pulse pressure sensors for measuring the pulse pressure at a close distance from a high-voltage discharge channel in a closed fluid volume by controlling the attenuation of the amplitude of the pressure signal. Practical value. We have developed, created, calibrated, used in scientific research waveguide pressure pulse sensors DTX-1. We propose sensors DTX-1 for sale in Ukraine and abroad. Sensors DTX-1 can be used to study pressure waves with a maximum amplitude value of up to 150 MPa in closed fluid volumes at a hydrostatic pressure of up to 20 MPa and a temperature of up to 80 °C.V. G. ZhekulO. P. SmirnovE. I. TaftajO. V. Khvoshchan I. S. ShvetsNational Technical University "Kharkiv Polytechnic Institute"articlepiezoelectric sensorpulse pressureelectrical characteristicshigh-voltage dischargeclosed volume of liquidElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 5, Pp 55-59 (2017)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic piezoelectric sensor
pulse pressure
electrical characteristics
high-voltage discharge
closed volume of liquid
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle piezoelectric sensor
pulse pressure
electrical characteristics
high-voltage discharge
closed volume of liquid
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
V. G. Zhekul
O. P. Smirnov
E. I. Taftaj
O. V. Khvoshchan
I. S. Shvets
PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE
description Purpose. Investigations of the characteristics of pressure waves presuppose the registration of the total profile of the pressure wave at a given point in space. For these purposes, various types of «pressure to the electrical signal» transmitters (sensors) are used. Most of the common sensors are unsuitable for measuring the pulse pressure in a closed water volume at high hydrostatic pressures, in particular to study the effect of a powerful high-voltage pulse discharge on increasing the inflow of minerals and drinking water in wells. The purpose of the work was to develop antijamming piezoelectric waveguide sensor for measuring pulse pressure at a close distance from a high-voltage discharge channel in a closed volume of a liquid. Methodology. We have applied the calibration method as used as a secondary standard, the theory of electrical circuits. Results. We have selected the design and the circuit solution of the waveguide pressure sensor. We have developed a waveguide pulse-pressure sensor DTX-1 with a measuring loop. This sensor makes it possible to study the spectral characteristics of pressure waves of high-voltage pulse discharge in closed volumes of liquid at a hydrostatic pressure of up to 20 MPa and a temperature of up to 80 °C. The sensor can be used to study pressure waves with a maximum amplitude value of up to 150 MPa and duration of up to 80 µs. According to the results of the calibration, the sensitivity of the developed sensor DTX-1 with a measuring loop is 0.0346 V/MPa. Originality. We have further developed the theory of designing the waveguide piezoelectric pulse pressure sensors for measuring the pulse pressure at a close distance from a high-voltage discharge channel in a closed fluid volume by controlling the attenuation of the amplitude of the pressure signal. Practical value. We have developed, created, calibrated, used in scientific research waveguide pressure pulse sensors DTX-1. We propose sensors DTX-1 for sale in Ukraine and abroad. Sensors DTX-1 can be used to study pressure waves with a maximum amplitude value of up to 150 MPa in closed fluid volumes at a hydrostatic pressure of up to 20 MPa and a temperature of up to 80 °C.
format article
author V. G. Zhekul
O. P. Smirnov
E. I. Taftaj
O. V. Khvoshchan
I. S. Shvets
author_facet V. G. Zhekul
O. P. Smirnov
E. I. Taftaj
O. V. Khvoshchan
I. S. Shvets
author_sort V. G. Zhekul
title PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE
title_short PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE
title_full PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE
title_fullStr PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE
title_full_unstemmed PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE
title_sort piezoelectric waveguide sensor for measuring pulse pressure in closed liquid volumes at high voltage electric discharge
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2017
url https://doaj.org/article/103ecb176d4a4f3eb734e2852cec7e89
work_keys_str_mv AT vgzhekul piezoelectricwaveguidesensorformeasuringpulsepressureinclosedliquidvolumesathighvoltageelectricdischarge
AT opsmirnov piezoelectricwaveguidesensorformeasuringpulsepressureinclosedliquidvolumesathighvoltageelectricdischarge
AT eitaftaj piezoelectricwaveguidesensorformeasuringpulsepressureinclosedliquidvolumesathighvoltageelectricdischarge
AT ovkhvoshchan piezoelectricwaveguidesensorformeasuringpulsepressureinclosedliquidvolumesathighvoltageelectricdischarge
AT isshvets piezoelectricwaveguidesensorformeasuringpulsepressureinclosedliquidvolumesathighvoltageelectricdischarge
_version_ 1718384334505771008