Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device
Naoki Tojo, Atsushi Hayashi, Akio Miyakoshi Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, Japan Purpose: To report a case of corneal decompensation due to the Ex-PRESS® mini glaucoma shunt device (Ex-PRESS).Patient and...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://doaj.org/article/113113157a4a4ad49f19cee0dc40cec6 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:113113157a4a4ad49f19cee0dc40cec6 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:113113157a4a4ad49f19cee0dc40cec62021-12-02T01:17:15ZCorneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device1177-5483https://doaj.org/article/113113157a4a4ad49f19cee0dc40cec62015-03-01T00:00:00Zhttp://www.dovepress.com/corneal-decompensation-following-filtering-surgery-with-the-ex-pressre-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483 Naoki Tojo, Atsushi Hayashi, Akio Miyakoshi Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, Japan Purpose: To report a case of corneal decompensation due to the Ex-PRESS® mini glaucoma shunt device (Ex-PRESS).Patient and methods: A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months.Results: We observed partial decompensation of the corneal endothelium adjacent to the filtering bleb. Specular microscopy revealed a marked decrease in the endothelial cell density at the center of the cornea.Conclusion: Anterior segment optical coherence tomography is very useful for evaluating corneal edema and the position of Ex-PRESS. It is important to follow up with an examination of the corneal endothelial cells. Keywords: Ex-PRESS, bullous keratopathy, trabeculectomy, complication, cornea Tojo NHayashi AMiyakoshi ADove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2015, Iss default, Pp 499-502 (2015) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Tojo N Hayashi A Miyakoshi A Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device |
description |
Naoki Tojo, Atsushi Hayashi, Akio Miyakoshi Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, Japan Purpose: To report a case of corneal decompensation due to the Ex-PRESS® mini glaucoma shunt device (Ex-PRESS).Patient and methods: A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months.Results: We observed partial decompensation of the corneal endothelium adjacent to the filtering bleb. Specular microscopy revealed a marked decrease in the endothelial cell density at the center of the cornea.Conclusion: Anterior segment optical coherence tomography is very useful for evaluating corneal edema and the position of Ex-PRESS. It is important to follow up with an examination of the corneal endothelial cells. Keywords: Ex-PRESS, bullous keratopathy, trabeculectomy, complication, cornea |
format |
article |
author |
Tojo N Hayashi A Miyakoshi A |
author_facet |
Tojo N Hayashi A Miyakoshi A |
author_sort |
Tojo N |
title |
Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device |
title_short |
Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device |
title_full |
Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device |
title_fullStr |
Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device |
title_full_unstemmed |
Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device |
title_sort |
corneal decompensation following filtering surgery with the ex-press® mini glaucoma shunt device |
publisher |
Dove Medical Press |
publishDate |
2015 |
url |
https://doaj.org/article/113113157a4a4ad49f19cee0dc40cec6 |
work_keys_str_mv |
AT tojon cornealdecompensationfollowingfilteringsurgerywiththeexpressregminiglaucomashuntdevice AT hayashia cornealdecompensationfollowingfilteringsurgerywiththeexpressregminiglaucomashuntdevice AT miyakoshia cornealdecompensationfollowingfilteringsurgerywiththeexpressregminiglaucomashuntdevice |
_version_ |
1718403119958720512 |