A new endocapsular open ring for prevention of anterior and posterior capsule opacification

Ioannis G Pallikaris, Nela R Stojanovic, Harilaos S Ginis Institute of Vision and Optics, Department of Medicine, University of Crete, Heraklion, Crete, Greece Purpose: The aim of this study is to demonstrate the functionality of a new design of a thick endocapsular open ring for prevention of ant...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Pallikaris IG, Stojanovic NR, Ginis HS
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://doaj.org/article/12e29ca3490c424dbde99afa888cf296
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:12e29ca3490c424dbde99afa888cf296
record_format dspace
spelling oai:doaj.org-article:12e29ca3490c424dbde99afa888cf2962021-12-02T00:53:40ZA new endocapsular open ring for prevention of anterior and posterior capsule opacification1177-5483https://doaj.org/article/12e29ca3490c424dbde99afa888cf2962016-11-01T00:00:00Zhttps://www.dovepress.com/a-new-endocapsular-open-ring-for-prevention-of-anterior-and-posterior--peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Ioannis G Pallikaris, Nela R Stojanovic, Harilaos S Ginis Institute of Vision and Optics, Department of Medicine, University of Crete, Heraklion, Crete, Greece Purpose: The aim of this study is to demonstrate the functionality of a new design of a thick endocapsular open ring for prevention of anterior capsule opacification (ACO) and posterior capsule opacification (PCO). Setting: The Institute of Vision and Optics, University of Crete and University Hospital of Heraklion, Crete, Greece. Design: Prospective, interventional pilot study. Methods: Fifteen patients (17 eyes) underwent cataract surgery with phacoemulsification. During surgery, a thick endocapsular open ring (peripheral capsule reconstructor) was inserted into the capsular bag, prior to intraocular lens (IOL) implantation. Six different models of IOL were implanted. Postoperatively, the degree of ACO and PCO was evaluated and described as none, mild, moderate, or severe. Results: The mean follow-up period was 30±8.06 months (range: 12–36 months). At the last follow-up, mild PCO was observed in only three eyes and mild ACO in three patients. The centration of IOLs was good in all but one eye, which had a tilted IOL. Conclusion: The results of this pilot study suggest that the implantation of a new design of thick endocapsular open ring is feasible and may contribute to the prevention of PCO and ACO after cataract surgery. Keywords: intraocular implant, cataract, phacoemulsification, siliconePallikaris IGStojanovic NRGinis HSDove Medical PressarticleCataractPosterior capsule opacificationIntraocular implantIntraocular lensOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 10, Pp 2205-2212 (2016)
institution DOAJ
collection DOAJ
language EN
topic Cataract
Posterior capsule opacification
Intraocular implant
Intraocular lens
Ophthalmology
RE1-994
spellingShingle Cataract
Posterior capsule opacification
Intraocular implant
Intraocular lens
Ophthalmology
RE1-994
Pallikaris IG
Stojanovic NR
Ginis HS
A new endocapsular open ring for prevention of anterior and posterior capsule opacification
description Ioannis G Pallikaris, Nela R Stojanovic, Harilaos S Ginis Institute of Vision and Optics, Department of Medicine, University of Crete, Heraklion, Crete, Greece Purpose: The aim of this study is to demonstrate the functionality of a new design of a thick endocapsular open ring for prevention of anterior capsule opacification (ACO) and posterior capsule opacification (PCO). Setting: The Institute of Vision and Optics, University of Crete and University Hospital of Heraklion, Crete, Greece. Design: Prospective, interventional pilot study. Methods: Fifteen patients (17 eyes) underwent cataract surgery with phacoemulsification. During surgery, a thick endocapsular open ring (peripheral capsule reconstructor) was inserted into the capsular bag, prior to intraocular lens (IOL) implantation. Six different models of IOL were implanted. Postoperatively, the degree of ACO and PCO was evaluated and described as none, mild, moderate, or severe. Results: The mean follow-up period was 30±8.06 months (range: 12–36 months). At the last follow-up, mild PCO was observed in only three eyes and mild ACO in three patients. The centration of IOLs was good in all but one eye, which had a tilted IOL. Conclusion: The results of this pilot study suggest that the implantation of a new design of thick endocapsular open ring is feasible and may contribute to the prevention of PCO and ACO after cataract surgery. Keywords: intraocular implant, cataract, phacoemulsification, silicone
format article
author Pallikaris IG
Stojanovic NR
Ginis HS
author_facet Pallikaris IG
Stojanovic NR
Ginis HS
author_sort Pallikaris IG
title A new endocapsular open ring for prevention of anterior and posterior capsule opacification
title_short A new endocapsular open ring for prevention of anterior and posterior capsule opacification
title_full A new endocapsular open ring for prevention of anterior and posterior capsule opacification
title_fullStr A new endocapsular open ring for prevention of anterior and posterior capsule opacification
title_full_unstemmed A new endocapsular open ring for prevention of anterior and posterior capsule opacification
title_sort new endocapsular open ring for prevention of anterior and posterior capsule opacification
publisher Dove Medical Press
publishDate 2016
url https://doaj.org/article/12e29ca3490c424dbde99afa888cf296
work_keys_str_mv AT pallikarisig anewendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification
AT stojanovicnr anewendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification
AT ginishs anewendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification
AT pallikarisig newendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification
AT stojanovicnr newendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification
AT ginishs newendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification
_version_ 1718403421206216704