A new endocapsular open ring for prevention of anterior and posterior capsule opacification
Ioannis G Pallikaris, Nela R Stojanovic, Harilaos S Ginis Institute of Vision and Optics, Department of Medicine, University of Crete, Heraklion, Crete, Greece Purpose: The aim of this study is to demonstrate the functionality of a new design of a thick endocapsular open ring for prevention of ant...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://doaj.org/article/12e29ca3490c424dbde99afa888cf296 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:12e29ca3490c424dbde99afa888cf296 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:12e29ca3490c424dbde99afa888cf2962021-12-02T00:53:40ZA new endocapsular open ring for prevention of anterior and posterior capsule opacification1177-5483https://doaj.org/article/12e29ca3490c424dbde99afa888cf2962016-11-01T00:00:00Zhttps://www.dovepress.com/a-new-endocapsular-open-ring-for-prevention-of-anterior-and-posterior--peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Ioannis G Pallikaris, Nela R Stojanovic, Harilaos S Ginis Institute of Vision and Optics, Department of Medicine, University of Crete, Heraklion, Crete, Greece Purpose: The aim of this study is to demonstrate the functionality of a new design of a thick endocapsular open ring for prevention of anterior capsule opacification (ACO) and posterior capsule opacification (PCO). Setting: The Institute of Vision and Optics, University of Crete and University Hospital of Heraklion, Crete, Greece. Design: Prospective, interventional pilot study. Methods: Fifteen patients (17 eyes) underwent cataract surgery with phacoemulsification. During surgery, a thick endocapsular open ring (peripheral capsule reconstructor) was inserted into the capsular bag, prior to intraocular lens (IOL) implantation. Six different models of IOL were implanted. Postoperatively, the degree of ACO and PCO was evaluated and described as none, mild, moderate, or severe. Results: The mean follow-up period was 30±8.06 months (range: 12–36 months). At the last follow-up, mild PCO was observed in only three eyes and mild ACO in three patients. The centration of IOLs was good in all but one eye, which had a tilted IOL. Conclusion: The results of this pilot study suggest that the implantation of a new design of thick endocapsular open ring is feasible and may contribute to the prevention of PCO and ACO after cataract surgery. Keywords: intraocular implant, cataract, phacoemulsification, siliconePallikaris IGStojanovic NRGinis HSDove Medical PressarticleCataractPosterior capsule opacificationIntraocular implantIntraocular lensOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 10, Pp 2205-2212 (2016) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Cataract Posterior capsule opacification Intraocular implant Intraocular lens Ophthalmology RE1-994 |
spellingShingle |
Cataract Posterior capsule opacification Intraocular implant Intraocular lens Ophthalmology RE1-994 Pallikaris IG Stojanovic NR Ginis HS A new endocapsular open ring for prevention of anterior and posterior capsule opacification |
description |
Ioannis G Pallikaris, Nela R Stojanovic, Harilaos S Ginis Institute of Vision and Optics, Department of Medicine, University of Crete, Heraklion, Crete, Greece Purpose: The aim of this study is to demonstrate the functionality of a new design of a thick endocapsular open ring for prevention of anterior capsule opacification (ACO) and posterior capsule opacification (PCO). Setting: The Institute of Vision and Optics, University of Crete and University Hospital of Heraklion, Crete, Greece. Design: Prospective, interventional pilot study. Methods: Fifteen patients (17 eyes) underwent cataract surgery with phacoemulsification. During surgery, a thick endocapsular open ring (peripheral capsule reconstructor) was inserted into the capsular bag, prior to intraocular lens (IOL) implantation. Six different models of IOL were implanted. Postoperatively, the degree of ACO and PCO was evaluated and described as none, mild, moderate, or severe. Results: The mean follow-up period was 30±8.06 months (range: 12–36 months). At the last follow-up, mild PCO was observed in only three eyes and mild ACO in three patients. The centration of IOLs was good in all but one eye, which had a tilted IOL. Conclusion: The results of this pilot study suggest that the implantation of a new design of thick endocapsular open ring is feasible and may contribute to the prevention of PCO and ACO after cataract surgery. Keywords: intraocular implant, cataract, phacoemulsification, silicone |
format |
article |
author |
Pallikaris IG Stojanovic NR Ginis HS |
author_facet |
Pallikaris IG Stojanovic NR Ginis HS |
author_sort |
Pallikaris IG |
title |
A new endocapsular open ring for prevention of anterior and posterior capsule opacification |
title_short |
A new endocapsular open ring for prevention of anterior and posterior capsule opacification |
title_full |
A new endocapsular open ring for prevention of anterior and posterior capsule opacification |
title_fullStr |
A new endocapsular open ring for prevention of anterior and posterior capsule opacification |
title_full_unstemmed |
A new endocapsular open ring for prevention of anterior and posterior capsule opacification |
title_sort |
new endocapsular open ring for prevention of anterior and posterior capsule opacification |
publisher |
Dove Medical Press |
publishDate |
2016 |
url |
https://doaj.org/article/12e29ca3490c424dbde99afa888cf296 |
work_keys_str_mv |
AT pallikarisig anewendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification AT stojanovicnr anewendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification AT ginishs anewendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification AT pallikarisig newendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification AT stojanovicnr newendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification AT ginishs newendocapsularopenringforpreventionofanteriorandposteriorcapsuleopacification |
_version_ |
1718403421206216704 |