Technical Performance of Textile-Based Dry Forehead Electrodes Compared With Medical-Grade Overnight Home Sleep Recordings

The current clinically used electroencephalography (EEG) sensors are not self-applicable. This complicates the recording of the brain’s electrical activity in unattended home polysomnography (PSG). When EEG is not recorded, the sleep architecture cannot be accurately determined, which dec...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Matias Rusanen, Samu Kainulainen, Henri Korkalainen, Laura Kalevo, Katja Myllymaa, Timo Leppanen, Juha Toyras, Erna Sif Arnardottir, Sami Myllymaa
Formato: article
Lenguaje:EN
Publicado: IEEE 2021
Materias:
Acceso en línea:https://doaj.org/article/14e6d76f81794ecfbd50e03c19a35d32
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:14e6d76f81794ecfbd50e03c19a35d32
record_format dspace
spelling oai:doaj.org-article:14e6d76f81794ecfbd50e03c19a35d322021-12-03T00:00:29ZTechnical Performance of Textile-Based Dry Forehead Electrodes Compared With Medical-Grade Overnight Home Sleep Recordings2169-353610.1109/ACCESS.2021.3128057https://doaj.org/article/14e6d76f81794ecfbd50e03c19a35d322021-01-01T00:00:00Zhttps://ieeexplore.ieee.org/document/9614117/https://doaj.org/toc/2169-3536The current clinically used electroencephalography (EEG) sensors are not self-applicable. This complicates the recording of the brain&#x2019;s electrical activity in unattended home polysomnography (PSG). When EEG is not recorded, the sleep architecture cannot be accurately determined, which decreases the accuracy of home-based diagnosis of sleep disorders. The aim of this study was to compare the technical performance of FocusBand, an easily applicable textile electrode headband, to that of clinical EEG and electrooculography (EOG) electrodes. Overnight unattended recordings were conducted at participants&#x2019; (<inline-formula> <tex-math notation="LaTeX">$n =10$ </tex-math></inline-formula>) homes. Signals were recorded using a portable Nox A1 PSG device. The FocusBand&#x2019;s forehead EEG (Fp1-Fp2) signals contained features that are visible at both, the standard EEG (F4-M1) and EOG (E1-M2) signals. The FocusBand&#x2019;s EEG signal amplitudes were significantly lower compared to standard EEG (F4-M1; average difference 98&#x0025;) and EOG (E1-M2; average difference 29&#x0025;) signals during all sleep stages. Despite the amplitude difference, forehead EEG signals displayed typical EEG characteristics related to certain sleep stages. However, the frequency content of the FocusBand-based signals was more similar to that of the standard EOG signals than that of standard EEG signals. The majority of the artifacts seen in the FocusBand signals were related to a loosened headband. High differences in the frequency content of the compared signals were also found during wakefulness, suggesting susceptibility of the textile electrodes to electrode movement artifacts. This study demonstrates that the forehead biopotential signals recorded using an easily attachable textile electrode headband could be useful in home-based sleep recordings.Matias RusanenSamu KainulainenHenri KorkalainenLaura KalevoKatja MyllymaaTimo LeppanenJuha ToyrasErna Sif ArnardottirSami MyllymaaIEEEarticleElectroencephalographyelectrooculographytextile electrodewearablessleepElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENIEEE Access, Vol 9, Pp 157902-157915 (2021)
institution DOAJ
collection DOAJ
language EN
topic Electroencephalography
electrooculography
textile electrode
wearables
sleep
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle Electroencephalography
electrooculography
textile electrode
wearables
sleep
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Matias Rusanen
Samu Kainulainen
Henri Korkalainen
Laura Kalevo
Katja Myllymaa
Timo Leppanen
Juha Toyras
Erna Sif Arnardottir
Sami Myllymaa
Technical Performance of Textile-Based Dry Forehead Electrodes Compared With Medical-Grade Overnight Home Sleep Recordings
description The current clinically used electroencephalography (EEG) sensors are not self-applicable. This complicates the recording of the brain&#x2019;s electrical activity in unattended home polysomnography (PSG). When EEG is not recorded, the sleep architecture cannot be accurately determined, which decreases the accuracy of home-based diagnosis of sleep disorders. The aim of this study was to compare the technical performance of FocusBand, an easily applicable textile electrode headband, to that of clinical EEG and electrooculography (EOG) electrodes. Overnight unattended recordings were conducted at participants&#x2019; (<inline-formula> <tex-math notation="LaTeX">$n =10$ </tex-math></inline-formula>) homes. Signals were recorded using a portable Nox A1 PSG device. The FocusBand&#x2019;s forehead EEG (Fp1-Fp2) signals contained features that are visible at both, the standard EEG (F4-M1) and EOG (E1-M2) signals. The FocusBand&#x2019;s EEG signal amplitudes were significantly lower compared to standard EEG (F4-M1; average difference 98&#x0025;) and EOG (E1-M2; average difference 29&#x0025;) signals during all sleep stages. Despite the amplitude difference, forehead EEG signals displayed typical EEG characteristics related to certain sleep stages. However, the frequency content of the FocusBand-based signals was more similar to that of the standard EOG signals than that of standard EEG signals. The majority of the artifacts seen in the FocusBand signals were related to a loosened headband. High differences in the frequency content of the compared signals were also found during wakefulness, suggesting susceptibility of the textile electrodes to electrode movement artifacts. This study demonstrates that the forehead biopotential signals recorded using an easily attachable textile electrode headband could be useful in home-based sleep recordings.
format article
author Matias Rusanen
Samu Kainulainen
Henri Korkalainen
Laura Kalevo
Katja Myllymaa
Timo Leppanen
Juha Toyras
Erna Sif Arnardottir
Sami Myllymaa
author_facet Matias Rusanen
Samu Kainulainen
Henri Korkalainen
Laura Kalevo
Katja Myllymaa
Timo Leppanen
Juha Toyras
Erna Sif Arnardottir
Sami Myllymaa
author_sort Matias Rusanen
title Technical Performance of Textile-Based Dry Forehead Electrodes Compared With Medical-Grade Overnight Home Sleep Recordings
title_short Technical Performance of Textile-Based Dry Forehead Electrodes Compared With Medical-Grade Overnight Home Sleep Recordings
title_full Technical Performance of Textile-Based Dry Forehead Electrodes Compared With Medical-Grade Overnight Home Sleep Recordings
title_fullStr Technical Performance of Textile-Based Dry Forehead Electrodes Compared With Medical-Grade Overnight Home Sleep Recordings
title_full_unstemmed Technical Performance of Textile-Based Dry Forehead Electrodes Compared With Medical-Grade Overnight Home Sleep Recordings
title_sort technical performance of textile-based dry forehead electrodes compared with medical-grade overnight home sleep recordings
publisher IEEE
publishDate 2021
url https://doaj.org/article/14e6d76f81794ecfbd50e03c19a35d32
work_keys_str_mv AT matiasrusanen technicalperformanceoftextilebaseddryforeheadelectrodescomparedwithmedicalgradeovernighthomesleeprecordings
AT samukainulainen technicalperformanceoftextilebaseddryforeheadelectrodescomparedwithmedicalgradeovernighthomesleeprecordings
AT henrikorkalainen technicalperformanceoftextilebaseddryforeheadelectrodescomparedwithmedicalgradeovernighthomesleeprecordings
AT laurakalevo technicalperformanceoftextilebaseddryforeheadelectrodescomparedwithmedicalgradeovernighthomesleeprecordings
AT katjamyllymaa technicalperformanceoftextilebaseddryforeheadelectrodescomparedwithmedicalgradeovernighthomesleeprecordings
AT timoleppanen technicalperformanceoftextilebaseddryforeheadelectrodescomparedwithmedicalgradeovernighthomesleeprecordings
AT juhatoyras technicalperformanceoftextilebaseddryforeheadelectrodescomparedwithmedicalgradeovernighthomesleeprecordings
AT ernasifarnardottir technicalperformanceoftextilebaseddryforeheadelectrodescomparedwithmedicalgradeovernighthomesleeprecordings
AT samimyllymaa technicalperformanceoftextilebaseddryforeheadelectrodescomparedwithmedicalgradeovernighthomesleeprecordings
_version_ 1718373973684649984