Analysis of heat exchanger in an air handling unit – A case study
Ventilation plays an important role in providing comfortable conditions for users and is also one of the most energy-consuming systems in the building. Due to successive regulations aimed at reducing the energy load of buildings towards zero-energy buildings, energy recovery systems in air handling...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN FR |
Publicado: |
EDP Sciences
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/1508fee10cad4f1592edc3393996bdd3 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:1508fee10cad4f1592edc3393996bdd3 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:1508fee10cad4f1592edc3393996bdd32021-11-12T11:44:34ZAnalysis of heat exchanger in an air handling unit – A case study2267-124210.1051/e3sconf/202132104018https://doaj.org/article/1508fee10cad4f1592edc3393996bdd32021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/97/e3sconf_icchmt2021_04018.pdfhttps://doaj.org/toc/2267-1242Ventilation plays an important role in providing comfortable conditions for users and is also one of the most energy-consuming systems in the building. Due to successive regulations aimed at reducing the energy load of buildings towards zero-energy buildings, energy recovery systems in air handling units have become an indispensable element. The high effectiveness of the entire system guarantees a reduction in energy demand. At very low or very high external temperatures, appropriate comfort conditions are provided by additional heaters or coolers. The subject of the paper is a ventilation system in a hotel located in southern Poland. The building is a faithful reconstruction of the historical saltworks adapted for the needs of the hotel. The air handling unit equipped with a rotary exchanger supplies air to hotel rooms located on two floors. The analysis includes the effectiveness of the air-handling unit operation under various external conditions, as well as the temperature changes during heat exchange. The results show the actual operation of the air-handling unit, which is particularly important in terms of reducing the energy consumption of the hotel.Borowski MarekZwolińska KlaudiaCzerwiński MarcinEDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 321, p 04018 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN FR |
topic |
Environmental sciences GE1-350 |
spellingShingle |
Environmental sciences GE1-350 Borowski Marek Zwolińska Klaudia Czerwiński Marcin Analysis of heat exchanger in an air handling unit – A case study |
description |
Ventilation plays an important role in providing comfortable conditions for users and is also one of the most energy-consuming systems in the building. Due to successive regulations aimed at reducing the energy load of buildings towards zero-energy buildings, energy recovery systems in air handling units have become an indispensable element. The high effectiveness of the entire system guarantees a reduction in energy demand. At very low or very high external temperatures, appropriate comfort conditions are provided by additional heaters or coolers. The subject of the paper is a ventilation system in a hotel located in southern Poland. The building is a faithful reconstruction of the historical saltworks adapted for the needs of the hotel. The air handling unit equipped with a rotary exchanger supplies air to hotel rooms located on two floors. The analysis includes the effectiveness of the air-handling unit operation under various external conditions, as well as the temperature changes during heat exchange. The results show the actual operation of the air-handling unit, which is particularly important in terms of reducing the energy consumption of the hotel. |
format |
article |
author |
Borowski Marek Zwolińska Klaudia Czerwiński Marcin |
author_facet |
Borowski Marek Zwolińska Klaudia Czerwiński Marcin |
author_sort |
Borowski Marek |
title |
Analysis of heat exchanger in an air handling unit – A case study |
title_short |
Analysis of heat exchanger in an air handling unit – A case study |
title_full |
Analysis of heat exchanger in an air handling unit – A case study |
title_fullStr |
Analysis of heat exchanger in an air handling unit – A case study |
title_full_unstemmed |
Analysis of heat exchanger in an air handling unit – A case study |
title_sort |
analysis of heat exchanger in an air handling unit – a case study |
publisher |
EDP Sciences |
publishDate |
2021 |
url |
https://doaj.org/article/1508fee10cad4f1592edc3393996bdd3 |
work_keys_str_mv |
AT borowskimarek analysisofheatexchangerinanairhandlingunitacasestudy AT zwolinskaklaudia analysisofheatexchangerinanairhandlingunitacasestudy AT czerwinskimarcin analysisofheatexchangerinanairhandlingunitacasestudy |
_version_ |
1718430540104728576 |