INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR

Purpose. Development of an intensity setter, which in a rational law changes the opening thyristor the voltage regulator and effectively to changing power supply voltage stator windings of the electric pump deepening, ensuring a smooth start in a wide range. Methodology. Electric submersible pump be...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: V.I. Lobov, K.V. Lobova
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2016
Materias:
Acceso en línea:https://doaj.org/article/150ebf56fd88455380e061d3832883c2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:150ebf56fd88455380e061d3832883c2
record_format dspace
spelling oai:doaj.org-article:150ebf56fd88455380e061d3832883c22021-12-02T16:12:21ZINTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR10.20998/2074-272X.2016.3.062074-272X2309-3404https://doaj.org/article/150ebf56fd88455380e061d3832883c22016-06-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2016.3.06/67621https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. Development of an intensity setter, which in a rational law changes the opening thyristor the voltage regulator and effectively to changing power supply voltage stator windings of the electric pump deepening, ensuring a smooth start in a wide range. Methodology. Electric submersible pump belongs to the small inertia electric, since it is not significant total moment of inertia, not exceeding two moments of inertia of the motor and static moment on the shaft does not exceed forty percent of the nominal torque. For technical requirements that electric acceleration time should have no less than twenty seconds or more. Office starting modes of electric submersible pumps economically justified using thyristor voltage regulator by forming the dial changes the intensity of the necessary legislation in time voltage feeding the stator windings. This ensures a smooth start right rotor of the electric submersible pump. Results. A block diagram of the intensity setter that is: with control unit, two units that form the exponential voltage supply emitter follower and regulatory elements. The mathematical expressions for voltage at the stator windings of the motor, changing exponentially, opening the angle of thyristor power unit thyristor the voltage regulator, which is determined through the initial angle of opening. Provided formula for pick-up voltage and minimum voltage, time constants, which are determined from the basic equations of motion and mechanical characteristics of the electric motor. Analytical investigated by the voltage dependence violation by changing the time constant flowing and growing exhibitor supply voltage stator electric circuit deepening pump. Originality. Proposed in the initial time on the stator windings of the electric pick-up voltage is applied. Under the influence of this voltage, motor rotor begins to accelerate. At the same time, pick-up voltage decreases the minimum startup voltage varies exponentially in which the rotor of the electric motor continues to rotate more steadily. Now the voltage at the motor stator windings increases exponentially to the nominal voltage of the supply network. This start flowing smoothly for the right time to establish nominal rotor speed of the motor. Practical value. Developed dial allows you to increase the intensity of the electric motor acceleration time and reduce the dynamic loads of the electric submersible pump. V.I. LobovK.V. LobovaNational Technical University "Kharkiv Polytechnic Institute"articlesubmersible pumpinduction motorthyristor voltage regulatoropening angle of thyristorintensity setterstart-upacceleration timeElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 3, Pp 36-39 (2016)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic submersible pump
induction motor
thyristor voltage regulator
opening angle of thyristor
intensity setter
start-up
acceleration time
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle submersible pump
induction motor
thyristor voltage regulator
opening angle of thyristor
intensity setter
start-up
acceleration time
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
V.I. Lobov
K.V. Lobova
INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
description Purpose. Development of an intensity setter, which in a rational law changes the opening thyristor the voltage regulator and effectively to changing power supply voltage stator windings of the electric pump deepening, ensuring a smooth start in a wide range. Methodology. Electric submersible pump belongs to the small inertia electric, since it is not significant total moment of inertia, not exceeding two moments of inertia of the motor and static moment on the shaft does not exceed forty percent of the nominal torque. For technical requirements that electric acceleration time should have no less than twenty seconds or more. Office starting modes of electric submersible pumps economically justified using thyristor voltage regulator by forming the dial changes the intensity of the necessary legislation in time voltage feeding the stator windings. This ensures a smooth start right rotor of the electric submersible pump. Results. A block diagram of the intensity setter that is: with control unit, two units that form the exponential voltage supply emitter follower and regulatory elements. The mathematical expressions for voltage at the stator windings of the motor, changing exponentially, opening the angle of thyristor power unit thyristor the voltage regulator, which is determined through the initial angle of opening. Provided formula for pick-up voltage and minimum voltage, time constants, which are determined from the basic equations of motion and mechanical characteristics of the electric motor. Analytical investigated by the voltage dependence violation by changing the time constant flowing and growing exhibitor supply voltage stator electric circuit deepening pump. Originality. Proposed in the initial time on the stator windings of the electric pick-up voltage is applied. Under the influence of this voltage, motor rotor begins to accelerate. At the same time, pick-up voltage decreases the minimum startup voltage varies exponentially in which the rotor of the electric motor continues to rotate more steadily. Now the voltage at the motor stator windings increases exponentially to the nominal voltage of the supply network. This start flowing smoothly for the right time to establish nominal rotor speed of the motor. Practical value. Developed dial allows you to increase the intensity of the electric motor acceleration time and reduce the dynamic loads of the electric submersible pump.
format article
author V.I. Lobov
K.V. Lobova
author_facet V.I. Lobov
K.V. Lobova
author_sort V.I. Lobov
title INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_short INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_full INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_fullStr INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_full_unstemmed INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_sort intensity setter for a device of smooth start of submersible pump electric motor
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2016
url https://doaj.org/article/150ebf56fd88455380e061d3832883c2
work_keys_str_mv AT vilobov intensitysetterforadeviceofsmoothstartofsubmersiblepumpelectricmotor
AT kvlobova intensitysetterforadeviceofsmoothstartofsubmersiblepumpelectricmotor
_version_ 1718384335543861248