ANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS

Purpose. The study of parallel operation optimal modes of transformer equipment for a variety of operating conditions: same or different types of transformers, with or without reactive power flows. Methodology. Losses of energy in transformers make 30 % of all losses. Therefore the choice of the eco...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: I. V. Khomenko, S. K. Berezka, I. V. Poliakov
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2016
Materias:
Acceso en línea:https://doaj.org/article/15a70e6550f14db2a6ec0c33c126ab64
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:15a70e6550f14db2a6ec0c33c126ab64
record_format dspace
spelling oai:doaj.org-article:15a70e6550f14db2a6ec0c33c126ab642021-12-02T16:19:12ZANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS10.20998/2074-272X.2016.6.122074-272X2309-3404https://doaj.org/article/15a70e6550f14db2a6ec0c33c126ab642016-12-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2016.6.12/82195https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. The study of parallel operation optimal modes of transformer equipment for a variety of operating conditions: same or different types of transformers, with or without reactive power flows. Methodology. Losses of energy in transformers make 30 % of all losses. Therefore the choice of the economically justified parallel operation of transformers is effective action to reduce losses. Typically, in the calculations of reactive power flows in the transformers are not taken into account. It is interesting to analyze the optimal operating conditions of transformers with and without reactive power flows. Results. Calculations for transformers in distribution networks showed that the inclusion of reactive power flows in transformers significant impact on the calculated optimum regimes of transformers. I. V. KhomenkoS. K. BerezkaI. V. Poliakov National Technical University "Kharkiv Polytechnic Institute"articletransformer equipmentparallel operationoptimal modereactive powereconomically reasonable modeElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 6, Pp 70-73 (2016)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic transformer equipment
parallel operation
optimal mode
reactive power
economically reasonable mode
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle transformer equipment
parallel operation
optimal mode
reactive power
economically reasonable mode
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
I. V. Khomenko
S. K. Berezka
I. V. Poliakov
ANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS
description Purpose. The study of parallel operation optimal modes of transformer equipment for a variety of operating conditions: same or different types of transformers, with or without reactive power flows. Methodology. Losses of energy in transformers make 30 % of all losses. Therefore the choice of the economically justified parallel operation of transformers is effective action to reduce losses. Typically, in the calculations of reactive power flows in the transformers are not taken into account. It is interesting to analyze the optimal operating conditions of transformers with and without reactive power flows. Results. Calculations for transformers in distribution networks showed that the inclusion of reactive power flows in transformers significant impact on the calculated optimum regimes of transformers.
format article
author I. V. Khomenko
S. K. Berezka
I. V. Poliakov
author_facet I. V. Khomenko
S. K. Berezka
I. V. Poliakov
author_sort I. V. Khomenko
title ANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS
title_short ANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS
title_full ANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS
title_fullStr ANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS
title_full_unstemmed ANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS
title_sort analysis of optimum operating modes of power transformers under operating conditions
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2016
url https://doaj.org/article/15a70e6550f14db2a6ec0c33c126ab64
work_keys_str_mv AT ivkhomenko analysisofoptimumoperatingmodesofpowertransformersunderoperatingconditions
AT skberezka analysisofoptimumoperatingmodesofpowertransformersunderoperatingconditions
AT ivpoliakov analysisofoptimumoperatingmodesofpowertransformersunderoperatingconditions
_version_ 1718384156361097216