Validity and Reliability of an Inertial Sensor Device for Specific Running Patterns in Soccer

Electronic performance tracking devices are largely employed in team sports to monitor performance and improve training. To date, global positioning system (GPS) based devices are those mainly used in soccer training. The aim of this study was to analyse the validity and reliability of the inertial...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Guglielmo Pillitteri, Ewan Thomas, Giuseppe Battaglia, Giovanni Angelo Navarra, Antonino Scardina, Viviana Gammino, Dario Ricchiari, Marianna Bellafiore
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
GPS
Acceso en línea:https://doaj.org/article/170cc581c1154b4e8a9284cbcb5da9a2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Electronic performance tracking devices are largely employed in team sports to monitor performance and improve training. To date, global positioning system (GPS) based devices are those mainly used in soccer training. The aim of this study was to analyse the validity and reliability of the inertial sensor device (ISD) in monitoring distance and speed in a soccer-specific circuit and how their performance compare to a GPS system. 44 young male soccer players (age: 14.9 ± 1.1, range 9–16, years, height: 1.65 ± 0.10 m, body mass: 56.3 ± 8.9 kg) playing in a non-professional soccer team in Italy, participated in the study. We assessed the players trough a soccer running sport-specific circuit. An ISD and a GPS were used to assess distance and speed. Data was compared to a video reference system, and the difference were quantified by means of the root mean square error (RMSE). Significant differences were found for both GPS and ISD devices for distance and speed. However, lower error for distance (dRMSE 2.23 ± 1.01 m and 5.75 ± 1.50 m, respectively) and speed (sRMSE 0.588 ± 0.152 m·s<sup>–1</sup> and 1.30 ± 0.422 m·s<sup>–1</sup>, respectively) were attained by the ISD compared to the GPS. Overall, our results revealed a statistically significant difference between systems in data monitoring for either distance and speed. However, results of this study showed that a smaller error was obtained with the ISD than the GPS device. Despite caution is warranted within the interpretation of these results, we observed a better practical applicability of the ISD due to its small size, lower cost and the possibility to use the device indoor.