Anterior chamber depth during hemodialysis

Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of S&...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Gracitelli CPB, Stefanini FR, Penha F, Góes MA, Draibe SA, Canziani ME, Paranhos Jr A
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://doaj.org/article/1852925973e14fff89b21e830b1be00d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:1852925973e14fff89b21e830b1be00d
record_format dspace
spelling oai:doaj.org-article:1852925973e14fff89b21e830b1be00d2021-12-02T11:32:07ZAnterior chamber depth during hemodialysis1177-54671177-5483https://doaj.org/article/1852925973e14fff89b21e830b1be00d2013-08-01T00:00:00Zhttp://www.dovepress.com/anterior-chamber-depth-during-hemodialysis-a14000https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of São Paulo – UNIFESP, São Paulo, Brazil Background: Exacerbation of chronic glaucoma or acute glaucoma is occasionally observed in patients undergoing hemodialysis (HD) because of anterior chamber depth changes during this therapy. Purpose: To evaluate anterior chamber depth and axial length in patients during HD sessions. Methods: A total of 67 eyes of 35 patients were prospectively enrolled. Axial length and anterior chamber depth were measured using ultrasonic biometry, and these measures were evaluated at three different times during HD sessions. Body weight and blood pressure pre- and post-HD were also measured. Results: There was no difference in the axial length between the three measurements (P = 0.241). We observed a significantly decreased anterior chamber depth (P = 0.002) during HD sessions. Conclusion: Our results support the idea that there is a change in anterior chamber depth in HD sessions. Keywords: anterior chamber, hemodialysis, axial length, acute angle-closure glaucomaGracitelli CPBStefanini FRPenha FGóes MADraibe SACanziani MEParanhos Jr ADove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2013, Iss default, Pp 1635-1639 (2013)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Gracitelli CPB
Stefanini FR
Penha F
Góes MA
Draibe SA
Canziani ME
Paranhos Jr A
Anterior chamber depth during hemodialysis
description Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of São Paulo – UNIFESP, São Paulo, Brazil Background: Exacerbation of chronic glaucoma or acute glaucoma is occasionally observed in patients undergoing hemodialysis (HD) because of anterior chamber depth changes during this therapy. Purpose: To evaluate anterior chamber depth and axial length in patients during HD sessions. Methods: A total of 67 eyes of 35 patients were prospectively enrolled. Axial length and anterior chamber depth were measured using ultrasonic biometry, and these measures were evaluated at three different times during HD sessions. Body weight and blood pressure pre- and post-HD were also measured. Results: There was no difference in the axial length between the three measurements (P = 0.241). We observed a significantly decreased anterior chamber depth (P = 0.002) during HD sessions. Conclusion: Our results support the idea that there is a change in anterior chamber depth in HD sessions. Keywords: anterior chamber, hemodialysis, axial length, acute angle-closure glaucoma
format article
author Gracitelli CPB
Stefanini FR
Penha F
Góes MA
Draibe SA
Canziani ME
Paranhos Jr A
author_facet Gracitelli CPB
Stefanini FR
Penha F
Góes MA
Draibe SA
Canziani ME
Paranhos Jr A
author_sort Gracitelli CPB
title Anterior chamber depth during hemodialysis
title_short Anterior chamber depth during hemodialysis
title_full Anterior chamber depth during hemodialysis
title_fullStr Anterior chamber depth during hemodialysis
title_full_unstemmed Anterior chamber depth during hemodialysis
title_sort anterior chamber depth during hemodialysis
publisher Dove Medical Press
publishDate 2013
url https://doaj.org/article/1852925973e14fff89b21e830b1be00d
work_keys_str_mv AT gracitellicpb anteriorchamberdepthduringhemodialysis
AT stefaninifr anteriorchamberdepthduringhemodialysis
AT penhaf anteriorchamberdepthduringhemodialysis
AT gampoacuteesma anteriorchamberdepthduringhemodialysis
AT draibesa anteriorchamberdepthduringhemodialysis
AT canzianime anteriorchamberdepthduringhemodialysis
AT paranhosjra anteriorchamberdepthduringhemodialysis
_version_ 1718395805709107200