Anterior chamber depth during hemodialysis
Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of S&...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/1852925973e14fff89b21e830b1be00d |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:1852925973e14fff89b21e830b1be00d |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:1852925973e14fff89b21e830b1be00d2021-12-02T11:32:07ZAnterior chamber depth during hemodialysis1177-54671177-5483https://doaj.org/article/1852925973e14fff89b21e830b1be00d2013-08-01T00:00:00Zhttp://www.dovepress.com/anterior-chamber-depth-during-hemodialysis-a14000https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of São Paulo – UNIFESP, São Paulo, Brazil Background: Exacerbation of chronic glaucoma or acute glaucoma is occasionally observed in patients undergoing hemodialysis (HD) because of anterior chamber depth changes during this therapy. Purpose: To evaluate anterior chamber depth and axial length in patients during HD sessions. Methods: A total of 67 eyes of 35 patients were prospectively enrolled. Axial length and anterior chamber depth were measured using ultrasonic biometry, and these measures were evaluated at three different times during HD sessions. Body weight and blood pressure pre- and post-HD were also measured. Results: There was no difference in the axial length between the three measurements (P = 0.241). We observed a significantly decreased anterior chamber depth (P = 0.002) during HD sessions. Conclusion: Our results support the idea that there is a change in anterior chamber depth in HD sessions. Keywords: anterior chamber, hemodialysis, axial length, acute angle-closure glaucomaGracitelli CPBStefanini FRPenha FGóes MADraibe SACanziani MEParanhos Jr ADove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2013, Iss default, Pp 1635-1639 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Gracitelli CPB Stefanini FR Penha F Góes MA Draibe SA Canziani ME Paranhos Jr A Anterior chamber depth during hemodialysis |
description |
Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of São Paulo – UNIFESP, São Paulo, Brazil Background: Exacerbation of chronic glaucoma or acute glaucoma is occasionally observed in patients undergoing hemodialysis (HD) because of anterior chamber depth changes during this therapy. Purpose: To evaluate anterior chamber depth and axial length in patients during HD sessions. Methods: A total of 67 eyes of 35 patients were prospectively enrolled. Axial length and anterior chamber depth were measured using ultrasonic biometry, and these measures were evaluated at three different times during HD sessions. Body weight and blood pressure pre- and post-HD were also measured. Results: There was no difference in the axial length between the three measurements (P = 0.241). We observed a significantly decreased anterior chamber depth (P = 0.002) during HD sessions. Conclusion: Our results support the idea that there is a change in anterior chamber depth in HD sessions. Keywords: anterior chamber, hemodialysis, axial length, acute angle-closure glaucoma |
format |
article |
author |
Gracitelli CPB Stefanini FR Penha F Góes MA Draibe SA Canziani ME Paranhos Jr A |
author_facet |
Gracitelli CPB Stefanini FR Penha F Góes MA Draibe SA Canziani ME Paranhos Jr A |
author_sort |
Gracitelli CPB |
title |
Anterior chamber depth during hemodialysis |
title_short |
Anterior chamber depth during hemodialysis |
title_full |
Anterior chamber depth during hemodialysis |
title_fullStr |
Anterior chamber depth during hemodialysis |
title_full_unstemmed |
Anterior chamber depth during hemodialysis |
title_sort |
anterior chamber depth during hemodialysis |
publisher |
Dove Medical Press |
publishDate |
2013 |
url |
https://doaj.org/article/1852925973e14fff89b21e830b1be00d |
work_keys_str_mv |
AT gracitellicpb anteriorchamberdepthduringhemodialysis AT stefaninifr anteriorchamberdepthduringhemodialysis AT penhaf anteriorchamberdepthduringhemodialysis AT gampoacuteesma anteriorchamberdepthduringhemodialysis AT draibesa anteriorchamberdepthduringhemodialysis AT canzianime anteriorchamberdepthduringhemodialysis AT paranhosjra anteriorchamberdepthduringhemodialysis |
_version_ |
1718395805709107200 |