In-and-out technique for intraocular lens scleral fixation

Jung Yeol Choi,1 Young Keun Han2,3 1Department of Ophthalmology, Jeju National University Hospital, Jeju, South Korea; 2Department of Ophthalmology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, South Korea; 3Department of Ophthalmology, Seoul National Unive...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Choi JY, Han YK
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://doaj.org/article/1976b1f70bc149c19068479b9c895a8f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:1976b1f70bc149c19068479b9c895a8f
record_format dspace
spelling oai:doaj.org-article:1976b1f70bc149c19068479b9c895a8f2021-12-02T00:18:16ZIn-and-out technique for intraocular lens scleral fixation1177-5483https://doaj.org/article/1976b1f70bc149c19068479b9c895a8f2018-07-01T00:00:00Zhttps://www.dovepress.com/in-and-out-technique-for-intraocular-lens-scleral-fixation-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Jung Yeol Choi,1 Young Keun Han2,3 1Department of Ophthalmology, Jeju National University Hospital, Jeju, South Korea; 2Department of Ophthalmology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, South Korea; 3Department of Ophthalmology, Seoul National University College of Medicine, Seoul, South Korea Abstract: We describe a modified scleral fixation method to facilitate the good centration and adequate tension of sutures at both ends with addition of an internal fixation knot that reduces decentering of the IOL in a patient with postsurgical aphakia. Using an ab externo suture technique to fixate the haptics to the scleral wall, an additional loop knot is tied 1 mm next to the fixation knot at the haptic. In the technique, an internalized suture and an additional suture knot is tied while holding it close to the fixation knot at the haptic using a needle holder or McPherson forceps. The externalized sutures are secured by taking a bite of transclera and tying the suture to itself. This technique is simple and easy, and adds an internal check valve to prevent excessive pull and decentering of the intraocular lens at one side. The internal check valve also serves as a criterion for the point of fixation at each end. Keywords: modified technique, intraocular lens scleral fixation, postsurgical aphakiaChoi JYHan YKDove Medical Pressarticlemodified techniqueintraocular lens scleral fixationOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 1279-1284 (2018)
institution DOAJ
collection DOAJ
language EN
topic modified technique
intraocular lens scleral fixation
Ophthalmology
RE1-994
spellingShingle modified technique
intraocular lens scleral fixation
Ophthalmology
RE1-994
Choi JY
Han YK
In-and-out technique for intraocular lens scleral fixation
description Jung Yeol Choi,1 Young Keun Han2,3 1Department of Ophthalmology, Jeju National University Hospital, Jeju, South Korea; 2Department of Ophthalmology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, South Korea; 3Department of Ophthalmology, Seoul National University College of Medicine, Seoul, South Korea Abstract: We describe a modified scleral fixation method to facilitate the good centration and adequate tension of sutures at both ends with addition of an internal fixation knot that reduces decentering of the IOL in a patient with postsurgical aphakia. Using an ab externo suture technique to fixate the haptics to the scleral wall, an additional loop knot is tied 1 mm next to the fixation knot at the haptic. In the technique, an internalized suture and an additional suture knot is tied while holding it close to the fixation knot at the haptic using a needle holder or McPherson forceps. The externalized sutures are secured by taking a bite of transclera and tying the suture to itself. This technique is simple and easy, and adds an internal check valve to prevent excessive pull and decentering of the intraocular lens at one side. The internal check valve also serves as a criterion for the point of fixation at each end. Keywords: modified technique, intraocular lens scleral fixation, postsurgical aphakia
format article
author Choi JY
Han YK
author_facet Choi JY
Han YK
author_sort Choi JY
title In-and-out technique for intraocular lens scleral fixation
title_short In-and-out technique for intraocular lens scleral fixation
title_full In-and-out technique for intraocular lens scleral fixation
title_fullStr In-and-out technique for intraocular lens scleral fixation
title_full_unstemmed In-and-out technique for intraocular lens scleral fixation
title_sort in-and-out technique for intraocular lens scleral fixation
publisher Dove Medical Press
publishDate 2018
url https://doaj.org/article/1976b1f70bc149c19068479b9c895a8f
work_keys_str_mv AT choijy inandouttechniqueforintraocularlensscleralfixation
AT hanyk inandouttechniqueforintraocularlensscleralfixation
_version_ 1718403786165190656