Experimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System
Over the past years, thermoelectric refrigeration has attracted considerable attention due to its compact size, reliability, and environmental friendliness. Traditional refrigeration systems use greenhouse gases, which significantly impacts our environment. Therefore, in this work, a thermoelectric...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/19ceb6e1cfdb40b3937b0e248df3320e |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:19ceb6e1cfdb40b3937b0e248df3320e |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:19ceb6e1cfdb40b3937b0e248df3320e2021-11-11T15:19:12ZExperimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System10.3390/app1121102882076-3417https://doaj.org/article/19ceb6e1cfdb40b3937b0e248df3320e2021-11-01T00:00:00Zhttps://www.mdpi.com/2076-3417/11/21/10288https://doaj.org/toc/2076-3417Over the past years, thermoelectric refrigeration has attracted considerable attention due to its compact size, reliability, and environmental friendliness. Traditional refrigeration systems use greenhouse gases, which significantly impacts our environment. Therefore, in this work, a thermoelectric cooler prototype refrigeration system, a solid-state device causing no harm to the environment, was constructed and tested experimentally. A heat sink was attached to the cold side of the thermoelectric cooler (TEC) to cool the air passing through the heat sink. In contrast, a cold plate was attached to the hot side of TEC to remove the generated heat with the help of the liquid circulating in the aluminium cold plate. Experiments were carried out by varying parameters such as input current to the TEC module, inlet air flow rate, water flow rate through the cold plate, etc. The experimental results indicate that the cooling effect is increased by approximately 40%, increasing current from 2A to 8A. However, the cooling effect was decreased with increasing inlet airflow rate by 58% when airflow rate increased from 2.25 m/s to 3.55 m/s. However, the system performance shows approximately 35% increment with an increase in fan speed. Furthermore, a decrease in the water flow rate from 3.04 L/m to 1.80 L/m showed a slight increment in the cooling by 15%.Yesha PatelAbu Raihan Mohammad SiddiqueMohammad Reza MohagheghSyeda Humaira TasnimShohel MahmudMDPI AGarticleair-conditioningbulk mean temperaturecoefficient of performance (COP)heat removal ratethermoelectric coolerTechnologyTEngineering (General). Civil engineering (General)TA1-2040Biology (General)QH301-705.5PhysicsQC1-999ChemistryQD1-999ENApplied Sciences, Vol 11, Iss 10288, p 10288 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
air-conditioning bulk mean temperature coefficient of performance (COP) heat removal rate thermoelectric cooler Technology T Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 |
spellingShingle |
air-conditioning bulk mean temperature coefficient of performance (COP) heat removal rate thermoelectric cooler Technology T Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 Yesha Patel Abu Raihan Mohammad Siddique Mohammad Reza Mohaghegh Syeda Humaira Tasnim Shohel Mahmud Experimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System |
description |
Over the past years, thermoelectric refrigeration has attracted considerable attention due to its compact size, reliability, and environmental friendliness. Traditional refrigeration systems use greenhouse gases, which significantly impacts our environment. Therefore, in this work, a thermoelectric cooler prototype refrigeration system, a solid-state device causing no harm to the environment, was constructed and tested experimentally. A heat sink was attached to the cold side of the thermoelectric cooler (TEC) to cool the air passing through the heat sink. In contrast, a cold plate was attached to the hot side of TEC to remove the generated heat with the help of the liquid circulating in the aluminium cold plate. Experiments were carried out by varying parameters such as input current to the TEC module, inlet air flow rate, water flow rate through the cold plate, etc. The experimental results indicate that the cooling effect is increased by approximately 40%, increasing current from 2A to 8A. However, the cooling effect was decreased with increasing inlet airflow rate by 58% when airflow rate increased from 2.25 m/s to 3.55 m/s. However, the system performance shows approximately 35% increment with an increase in fan speed. Furthermore, a decrease in the water flow rate from 3.04 L/m to 1.80 L/m showed a slight increment in the cooling by 15%. |
format |
article |
author |
Yesha Patel Abu Raihan Mohammad Siddique Mohammad Reza Mohaghegh Syeda Humaira Tasnim Shohel Mahmud |
author_facet |
Yesha Patel Abu Raihan Mohammad Siddique Mohammad Reza Mohaghegh Syeda Humaira Tasnim Shohel Mahmud |
author_sort |
Yesha Patel |
title |
Experimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System |
title_short |
Experimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System |
title_full |
Experimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System |
title_fullStr |
Experimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System |
title_full_unstemmed |
Experimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System |
title_sort |
experimental investigation of the cooling effect generated by a heat sink integrated thermoelectric-based u-shaped air-conditioning system |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/19ceb6e1cfdb40b3937b0e248df3320e |
work_keys_str_mv |
AT yeshapatel experimentalinvestigationofthecoolingeffectgeneratedbyaheatsinkintegratedthermoelectricbasedushapedairconditioningsystem AT aburaihanmohammadsiddique experimentalinvestigationofthecoolingeffectgeneratedbyaheatsinkintegratedthermoelectricbasedushapedairconditioningsystem AT mohammadrezamohaghegh experimentalinvestigationofthecoolingeffectgeneratedbyaheatsinkintegratedthermoelectricbasedushapedairconditioningsystem AT syedahumairatasnim experimentalinvestigationofthecoolingeffectgeneratedbyaheatsinkintegratedthermoelectricbasedushapedairconditioningsystem AT shohelmahmud experimentalinvestigationofthecoolingeffectgeneratedbyaheatsinkintegratedthermoelectricbasedushapedairconditioningsystem |
_version_ |
1718435353470173184 |