A comparison of diagnostic performance between two quantitative rapid fecal calprotectin assays in detecting active inflammatory bowel disease.

<h4>Background</h4>Fecal calprotectin (FC) is widely used for the diagnosis and monitoring disease activity of inflammatory bowel disease (IBD). Quantitative rapid assays can be a reliable alternative to the time-consuming assay. This study aimed to evaluate and compare the diagnostic pe...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jong-Mi Lee, Joo Hee Jang, Ji Hyeong Ryu, Jaeeun Yoo, Bo-In Lee, Seung-Jun Kim, Eun-Jee Oh
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/1a2dc459e8a74099aee5e883aa7926cd
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:<h4>Background</h4>Fecal calprotectin (FC) is widely used for the diagnosis and monitoring disease activity of inflammatory bowel disease (IBD). Quantitative rapid assays can be a reliable alternative to the time-consuming assay. This study aimed to evaluate and compare the diagnostic performance of two quantitative rapid FC assays (Ichroma calprotectin, and Buhlmann Quantum blue).<h4>Methods</h4>A total of 192 patients were included in this study; 84 patients with IBD (67 ulcerative colitis and 17 Crohn's disease) and 108 patients with non-IBD. We compared quantitative FC levels in different disease statuses and evaluated the correlation between the FC results of the two FC kits. Diagnostic performances in predicting active IBD were evaluated in reference to different cut-off levels.<h4>Results</h4>The FC levels in 45 patients with active IBD as defined by endoscopic score were significantly higher compared to the inactive IBD and other diseases (P<0.05). Although the two assays' results correlated (r = 0.642, P < 0.001), a significant deviation was observed (y (Buhlmannn) = -45.2 +8.9X (Ichroma)). The Diagnostic performances in predicting active IBD were comparable as area under the curve (AUC), 0.812, cut-off, 50, sensitivity, 64.4%, and specificity, 85.0% for iChroma assay and AUC, 0.826, cut-off, 100, sensitivity, 84.4%, and specificity 61.9% for Buhlmann Quantum Blue assay. FC levels using a cut-off of > 250 μg/g confirmed 85.7% (iChroma) and 64.1% (Buhlmann) of active IBD patients.<h4>Conclusion</h4>The results of the two rapid FC assays iChroma and Buhlmann showed a significant correlation, but the two test results were not interchangeable. With optimized cut-off values, rapid FC tests could be helpful in the diagnosis of IBD and differentiating active IBD from inactive or organic bowel disease.