Laboratory evaluation of twelve portable devices for medicine quality screening.

<h4>Background</h4>Post-market surveillance is a key regulatory function to prevent substandard and falsified (SF) medicines from being consumed by patients. Field deployable technologies offer the potential for rapid objective screening for SF medicines.<h4>Methods and findings<...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Stephen C Zambrzycki, Celine Caillet, Serena Vickers, Marcos Bouza, David V Donndelinger, Laura C Geben, Matthew C Bernier, Paul N Newton, Facundo M Fernández
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
Acceso en línea:https://doaj.org/article/1b4cae14dc04440d863eba3cc2483985
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:1b4cae14dc04440d863eba3cc2483985
record_format dspace
spelling oai:doaj.org-article:1b4cae14dc04440d863eba3cc24839852021-12-02T20:24:00ZLaboratory evaluation of twelve portable devices for medicine quality screening.1935-27271935-273510.1371/journal.pntd.0009360https://doaj.org/article/1b4cae14dc04440d863eba3cc24839852021-09-01T00:00:00Zhttps://doi.org/10.1371/journal.pntd.0009360https://doaj.org/toc/1935-2727https://doaj.org/toc/1935-2735<h4>Background</h4>Post-market surveillance is a key regulatory function to prevent substandard and falsified (SF) medicines from being consumed by patients. Field deployable technologies offer the potential for rapid objective screening for SF medicines.<h4>Methods and findings</h4>We evaluated twelve devices: three near infrared spectrometers (MicroPHAZIR RX, NIR-S-G1, Neospectra 2.5), two Raman spectrometers (Progeny, TruScan RM), one mid-infrared spectrometer (4500a), one disposable colorimetric assay (Paper Analytical Devices, PAD), one disposable immunoassay (Rapid Diagnostic Test, RDT), one portable liquid chromatograph (C-Vue), one microfluidic system (PharmaChk), one mass spectrometer (QDa), and one thin layer chromatography kit (GPHF-Minilab). Each device was tested with a series of field collected medicines (FCM) along with simulated medicines (SIM) formulated in a laboratory. The FCM and SIM ranged from samples with good quality active pharmaceutical ingredient (API) concentrations, reduced concentrations of API (80% and 50% of the API), no API, and the wrong API. All the devices had high sensitivities (91.5 to 100.0%) detecting medicines with no API or the wrong API. However, the sensitivities of each device towards samples with 50% and 80% API varied greatly, from 0% to 100%. The infrared and Raman spectrometers had variable sensitivities for detecting samples with 50% and 80% API (from 5.6% to 50.0%). The devices with the ability to quantitate API (C-Vue, PharmaChk, QDa) had sensitivities ranging from 91.7% to 100% to detect all poor quality samples. The specificity was lower for the quantitative C-Vue, PharmaChk, & QDa (50.0% to 91.7%) than for all the other devices in this study (95.5% to 100%).<h4>Conclusions</h4>The twelve devices evaluated could detect medicines with the wrong or none of the APIs, consistent with falsified medicines, with high accuracy. However, API quantitation to detect formulations similar to those commonly found in substandards proved more difficult, requiring further technological innovation.Stephen C ZambrzyckiCeline CailletSerena VickersMarcos BouzaDavid V DonndelingerLaura C GebenMatthew C BernierPaul N NewtonFacundo M FernándezPublic Library of Science (PLoS)articleArctic medicine. Tropical medicineRC955-962Public aspects of medicineRA1-1270ENPLoS Neglected Tropical Diseases, Vol 15, Iss 9, p e0009360 (2021)
institution DOAJ
collection DOAJ
language EN
topic Arctic medicine. Tropical medicine
RC955-962
Public aspects of medicine
RA1-1270
spellingShingle Arctic medicine. Tropical medicine
RC955-962
Public aspects of medicine
RA1-1270
Stephen C Zambrzycki
Celine Caillet
Serena Vickers
Marcos Bouza
David V Donndelinger
Laura C Geben
Matthew C Bernier
Paul N Newton
Facundo M Fernández
Laboratory evaluation of twelve portable devices for medicine quality screening.
description <h4>Background</h4>Post-market surveillance is a key regulatory function to prevent substandard and falsified (SF) medicines from being consumed by patients. Field deployable technologies offer the potential for rapid objective screening for SF medicines.<h4>Methods and findings</h4>We evaluated twelve devices: three near infrared spectrometers (MicroPHAZIR RX, NIR-S-G1, Neospectra 2.5), two Raman spectrometers (Progeny, TruScan RM), one mid-infrared spectrometer (4500a), one disposable colorimetric assay (Paper Analytical Devices, PAD), one disposable immunoassay (Rapid Diagnostic Test, RDT), one portable liquid chromatograph (C-Vue), one microfluidic system (PharmaChk), one mass spectrometer (QDa), and one thin layer chromatography kit (GPHF-Minilab). Each device was tested with a series of field collected medicines (FCM) along with simulated medicines (SIM) formulated in a laboratory. The FCM and SIM ranged from samples with good quality active pharmaceutical ingredient (API) concentrations, reduced concentrations of API (80% and 50% of the API), no API, and the wrong API. All the devices had high sensitivities (91.5 to 100.0%) detecting medicines with no API or the wrong API. However, the sensitivities of each device towards samples with 50% and 80% API varied greatly, from 0% to 100%. The infrared and Raman spectrometers had variable sensitivities for detecting samples with 50% and 80% API (from 5.6% to 50.0%). The devices with the ability to quantitate API (C-Vue, PharmaChk, QDa) had sensitivities ranging from 91.7% to 100% to detect all poor quality samples. The specificity was lower for the quantitative C-Vue, PharmaChk, & QDa (50.0% to 91.7%) than for all the other devices in this study (95.5% to 100%).<h4>Conclusions</h4>The twelve devices evaluated could detect medicines with the wrong or none of the APIs, consistent with falsified medicines, with high accuracy. However, API quantitation to detect formulations similar to those commonly found in substandards proved more difficult, requiring further technological innovation.
format article
author Stephen C Zambrzycki
Celine Caillet
Serena Vickers
Marcos Bouza
David V Donndelinger
Laura C Geben
Matthew C Bernier
Paul N Newton
Facundo M Fernández
author_facet Stephen C Zambrzycki
Celine Caillet
Serena Vickers
Marcos Bouza
David V Donndelinger
Laura C Geben
Matthew C Bernier
Paul N Newton
Facundo M Fernández
author_sort Stephen C Zambrzycki
title Laboratory evaluation of twelve portable devices for medicine quality screening.
title_short Laboratory evaluation of twelve portable devices for medicine quality screening.
title_full Laboratory evaluation of twelve portable devices for medicine quality screening.
title_fullStr Laboratory evaluation of twelve portable devices for medicine quality screening.
title_full_unstemmed Laboratory evaluation of twelve portable devices for medicine quality screening.
title_sort laboratory evaluation of twelve portable devices for medicine quality screening.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/1b4cae14dc04440d863eba3cc2483985
work_keys_str_mv AT stephenczambrzycki laboratoryevaluationoftwelveportabledevicesformedicinequalityscreening
AT celinecaillet laboratoryevaluationoftwelveportabledevicesformedicinequalityscreening
AT serenavickers laboratoryevaluationoftwelveportabledevicesformedicinequalityscreening
AT marcosbouza laboratoryevaluationoftwelveportabledevicesformedicinequalityscreening
AT davidvdonndelinger laboratoryevaluationoftwelveportabledevicesformedicinequalityscreening
AT lauracgeben laboratoryevaluationoftwelveportabledevicesformedicinequalityscreening
AT matthewcbernier laboratoryevaluationoftwelveportabledevicesformedicinequalityscreening
AT paulnnewton laboratoryevaluationoftwelveportabledevicesformedicinequalityscreening
AT facundomfernandez laboratoryevaluationoftwelveportabledevicesformedicinequalityscreening
_version_ 1718374093642792960