Derivation and validation of gray-box models to estimate noninvasive in-vivo percentage glycated hemoglobin using digital volume pulse waveform

Abstract Glycated hemoglobin and blood oxygenation are the two most important factors for monitoring a patient’s average blood glucose and blood oxygen levels. Digital volume pulse acquisition is a convenient method, even for a person with no previous training or experience, can be utilized to estim...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Shifat Hossain, Shantanu Sen Gupta, Tae-Ho Kwon, Ki-Doo Kim
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/1c6cb457f2c94361bc76fe57e818c06d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:1c6cb457f2c94361bc76fe57e818c06d
record_format dspace
spelling oai:doaj.org-article:1c6cb457f2c94361bc76fe57e818c06d2021-12-02T17:47:23ZDerivation and validation of gray-box models to estimate noninvasive in-vivo percentage glycated hemoglobin using digital volume pulse waveform10.1038/s41598-021-91527-22045-2322https://doaj.org/article/1c6cb457f2c94361bc76fe57e818c06d2021-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-91527-2https://doaj.org/toc/2045-2322Abstract Glycated hemoglobin and blood oxygenation are the two most important factors for monitoring a patient’s average blood glucose and blood oxygen levels. Digital volume pulse acquisition is a convenient method, even for a person with no previous training or experience, can be utilized to estimate the two abovementioned physiological parameters. The physiological basis assumptions are utilized to develop two-finger models for estimating the percent glycated hemoglobin and blood oxygenation levels. The first model consists of a blood-vessel-only hypothesis, whereas the second model is based on a whole-finger model system. The two gray-box systems were validated on diabetic and nondiabetic patients. The mean absolute errors for the percent glycated hemoglobin (%HbA1c) and percent oxygen saturation (%SpO2) were 0.375 and 1.676 for the blood-vessel model and 0.271 and 1.395 for the whole-finger model, respectively. The repeatability analysis indicated that these models resulted in a mean percent coefficient of variation (%CV) of 2.08% and 1.74% for %HbA1c and 0.54% and 0.49% for %SpO2 in the respective models. Herein, both models exhibited similar performances (HbA1c estimation Pearson’s R values were 0.92 and 0.96, respectively), despite the model assumptions differing greatly. The bias values in the Bland–Altman analysis for both models were – 0.03 ± 0.458 and – 0.063 ± 0.326 for HbA1c estimation, and 0.178 ± 2.002 and – 0.246 ± 1.69 for SpO2 estimation, respectively. Both models have a very high potential for use in real-world scenarios. The whole-finger model with a lower standard deviation in bias and higher Pearson’s R value performs better in terms of higher precision and accuracy than the blood-vessel model.Shifat HossainShantanu Sen GuptaTae-Ho KwonKi-Doo KimNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-18 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Shifat Hossain
Shantanu Sen Gupta
Tae-Ho Kwon
Ki-Doo Kim
Derivation and validation of gray-box models to estimate noninvasive in-vivo percentage glycated hemoglobin using digital volume pulse waveform
description Abstract Glycated hemoglobin and blood oxygenation are the two most important factors for monitoring a patient’s average blood glucose and blood oxygen levels. Digital volume pulse acquisition is a convenient method, even for a person with no previous training or experience, can be utilized to estimate the two abovementioned physiological parameters. The physiological basis assumptions are utilized to develop two-finger models for estimating the percent glycated hemoglobin and blood oxygenation levels. The first model consists of a blood-vessel-only hypothesis, whereas the second model is based on a whole-finger model system. The two gray-box systems were validated on diabetic and nondiabetic patients. The mean absolute errors for the percent glycated hemoglobin (%HbA1c) and percent oxygen saturation (%SpO2) were 0.375 and 1.676 for the blood-vessel model and 0.271 and 1.395 for the whole-finger model, respectively. The repeatability analysis indicated that these models resulted in a mean percent coefficient of variation (%CV) of 2.08% and 1.74% for %HbA1c and 0.54% and 0.49% for %SpO2 in the respective models. Herein, both models exhibited similar performances (HbA1c estimation Pearson’s R values were 0.92 and 0.96, respectively), despite the model assumptions differing greatly. The bias values in the Bland–Altman analysis for both models were – 0.03 ± 0.458 and – 0.063 ± 0.326 for HbA1c estimation, and 0.178 ± 2.002 and – 0.246 ± 1.69 for SpO2 estimation, respectively. Both models have a very high potential for use in real-world scenarios. The whole-finger model with a lower standard deviation in bias and higher Pearson’s R value performs better in terms of higher precision and accuracy than the blood-vessel model.
format article
author Shifat Hossain
Shantanu Sen Gupta
Tae-Ho Kwon
Ki-Doo Kim
author_facet Shifat Hossain
Shantanu Sen Gupta
Tae-Ho Kwon
Ki-Doo Kim
author_sort Shifat Hossain
title Derivation and validation of gray-box models to estimate noninvasive in-vivo percentage glycated hemoglobin using digital volume pulse waveform
title_short Derivation and validation of gray-box models to estimate noninvasive in-vivo percentage glycated hemoglobin using digital volume pulse waveform
title_full Derivation and validation of gray-box models to estimate noninvasive in-vivo percentage glycated hemoglobin using digital volume pulse waveform
title_fullStr Derivation and validation of gray-box models to estimate noninvasive in-vivo percentage glycated hemoglobin using digital volume pulse waveform
title_full_unstemmed Derivation and validation of gray-box models to estimate noninvasive in-vivo percentage glycated hemoglobin using digital volume pulse waveform
title_sort derivation and validation of gray-box models to estimate noninvasive in-vivo percentage glycated hemoglobin using digital volume pulse waveform
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/1c6cb457f2c94361bc76fe57e818c06d
work_keys_str_mv AT shifathossain derivationandvalidationofgrayboxmodelstoestimatenoninvasiveinvivopercentageglycatedhemoglobinusingdigitalvolumepulsewaveform
AT shantanusengupta derivationandvalidationofgrayboxmodelstoestimatenoninvasiveinvivopercentageglycatedhemoglobinusingdigitalvolumepulsewaveform
AT taehokwon derivationandvalidationofgrayboxmodelstoestimatenoninvasiveinvivopercentageglycatedhemoglobinusingdigitalvolumepulsewaveform
AT kidookim derivationandvalidationofgrayboxmodelstoestimatenoninvasiveinvivopercentageglycatedhemoglobinusingdigitalvolumepulsewaveform
_version_ 1718379451583037440