Lensless Multispectral Camera Based on a Coded Aperture Array
Multispectral imaging can be applied to water quality monitoring, medical diagnosis, and other applications, but the principle of multispectral imaging is different from the principle of hyper-spectral imaging. Multispectral imaging is generally achieved through filters, so multiple photos are requi...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/1c9003f302d7467cb0271eb0144bef33 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:1c9003f302d7467cb0271eb0144bef33 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:1c9003f302d7467cb0271eb0144bef332021-11-25T18:59:04ZLensless Multispectral Camera Based on a Coded Aperture Array10.3390/s212277571424-8220https://doaj.org/article/1c9003f302d7467cb0271eb0144bef332021-11-01T00:00:00Zhttps://www.mdpi.com/1424-8220/21/22/7757https://doaj.org/toc/1424-8220Multispectral imaging can be applied to water quality monitoring, medical diagnosis, and other applications, but the principle of multispectral imaging is different from the principle of hyper-spectral imaging. Multispectral imaging is generally achieved through filters, so multiple photos are required to obtain spectral information. Using multiple detectors to take pictures at the same time increases the complexity and cost of the system. This paper proposes a simple multispectral camera based on lensless imaging, which does not require multiple lenses. The core of the system is the multispectral coding aperture. The coding aperture is divided into different regions and each region transmits the light of one wavelength, such that the spectral information of the target can be coded. By solving the inverse problem of sparse constraints, the multispectral information of the target is inverted. Herein, we analyzed the characteristics of this multispectral camera and developed a principle prototype to obtain experimental results.Jianwei WangYan ZhaoMDPI AGarticlemultispectral imaginglensless imagingcode apertureChemical technologyTP1-1185ENSensors, Vol 21, Iss 7757, p 7757 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
multispectral imaging lensless imaging code aperture Chemical technology TP1-1185 |
spellingShingle |
multispectral imaging lensless imaging code aperture Chemical technology TP1-1185 Jianwei Wang Yan Zhao Lensless Multispectral Camera Based on a Coded Aperture Array |
description |
Multispectral imaging can be applied to water quality monitoring, medical diagnosis, and other applications, but the principle of multispectral imaging is different from the principle of hyper-spectral imaging. Multispectral imaging is generally achieved through filters, so multiple photos are required to obtain spectral information. Using multiple detectors to take pictures at the same time increases the complexity and cost of the system. This paper proposes a simple multispectral camera based on lensless imaging, which does not require multiple lenses. The core of the system is the multispectral coding aperture. The coding aperture is divided into different regions and each region transmits the light of one wavelength, such that the spectral information of the target can be coded. By solving the inverse problem of sparse constraints, the multispectral information of the target is inverted. Herein, we analyzed the characteristics of this multispectral camera and developed a principle prototype to obtain experimental results. |
format |
article |
author |
Jianwei Wang Yan Zhao |
author_facet |
Jianwei Wang Yan Zhao |
author_sort |
Jianwei Wang |
title |
Lensless Multispectral Camera Based on a Coded Aperture Array |
title_short |
Lensless Multispectral Camera Based on a Coded Aperture Array |
title_full |
Lensless Multispectral Camera Based on a Coded Aperture Array |
title_fullStr |
Lensless Multispectral Camera Based on a Coded Aperture Array |
title_full_unstemmed |
Lensless Multispectral Camera Based on a Coded Aperture Array |
title_sort |
lensless multispectral camera based on a coded aperture array |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/1c9003f302d7467cb0271eb0144bef33 |
work_keys_str_mv |
AT jianweiwang lenslessmultispectralcamerabasedonacodedaperturearray AT yanzhao lenslessmultispectralcamerabasedonacodedaperturearray |
_version_ |
1718410449506009088 |