Openspritzer: an open hardware pressure ejection system for reliably delivering picolitre volumes
Abstract The ability to reliably and precisely deliver picolitre volumes is an important component of biological research. Here we describe a high-performance, low-cost, open hardware pressure ejection system (Openspritzer), which can be constructed from off the shelf components. The device is capab...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/1d30c7d3322840d9baf96af0c2d7ff61 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:1d30c7d3322840d9baf96af0c2d7ff61 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:1d30c7d3322840d9baf96af0c2d7ff612021-12-02T15:04:53ZOpenspritzer: an open hardware pressure ejection system for reliably delivering picolitre volumes10.1038/s41598-017-02301-22045-2322https://doaj.org/article/1d30c7d3322840d9baf96af0c2d7ff612017-05-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-02301-2https://doaj.org/toc/2045-2322Abstract The ability to reliably and precisely deliver picolitre volumes is an important component of biological research. Here we describe a high-performance, low-cost, open hardware pressure ejection system (Openspritzer), which can be constructed from off the shelf components. The device is capable of delivering minute doses of reagents to a wide range of biological and chemical systems. In this work, we characterise the performance of the device and compare it to a popular commercial system using two-photon fluorescence microscopy. We found that Openspritzer provides the same level of control over delivered reagent dose as the commercial system. Next, we demonstrate the utility of Openspritzer in a series of standard neurobiological applications. First, we used Openspritzer to deliver precise amounts of reagents to hippocampal neurons to elicit time- and dose-precise responses on neuronal voltage. Second, we used Openspritzer to deliver infectious viral and bacterial agents to living tissue. This included viral transfection of hippocampal interneurons with channelrhodopsin for the optogenetic manipulation of hippocampal circuitry with light. We anticipate that due to its high performance and low cost Openspritzer will be of interest to a broad range of researchers working in the life and physical sciences.C. J. FormanH. TomesB. MboboR. J. BurmanM. JacobsT BadenJ. V. RaimondoNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-11 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q C. J. Forman H. Tomes B. Mbobo R. J. Burman M. Jacobs T Baden J. V. Raimondo Openspritzer: an open hardware pressure ejection system for reliably delivering picolitre volumes |
description |
Abstract The ability to reliably and precisely deliver picolitre volumes is an important component of biological research. Here we describe a high-performance, low-cost, open hardware pressure ejection system (Openspritzer), which can be constructed from off the shelf components. The device is capable of delivering minute doses of reagents to a wide range of biological and chemical systems. In this work, we characterise the performance of the device and compare it to a popular commercial system using two-photon fluorescence microscopy. We found that Openspritzer provides the same level of control over delivered reagent dose as the commercial system. Next, we demonstrate the utility of Openspritzer in a series of standard neurobiological applications. First, we used Openspritzer to deliver precise amounts of reagents to hippocampal neurons to elicit time- and dose-precise responses on neuronal voltage. Second, we used Openspritzer to deliver infectious viral and bacterial agents to living tissue. This included viral transfection of hippocampal interneurons with channelrhodopsin for the optogenetic manipulation of hippocampal circuitry with light. We anticipate that due to its high performance and low cost Openspritzer will be of interest to a broad range of researchers working in the life and physical sciences. |
format |
article |
author |
C. J. Forman H. Tomes B. Mbobo R. J. Burman M. Jacobs T Baden J. V. Raimondo |
author_facet |
C. J. Forman H. Tomes B. Mbobo R. J. Burman M. Jacobs T Baden J. V. Raimondo |
author_sort |
C. J. Forman |
title |
Openspritzer: an open hardware pressure ejection system for reliably delivering picolitre volumes |
title_short |
Openspritzer: an open hardware pressure ejection system for reliably delivering picolitre volumes |
title_full |
Openspritzer: an open hardware pressure ejection system for reliably delivering picolitre volumes |
title_fullStr |
Openspritzer: an open hardware pressure ejection system for reliably delivering picolitre volumes |
title_full_unstemmed |
Openspritzer: an open hardware pressure ejection system for reliably delivering picolitre volumes |
title_sort |
openspritzer: an open hardware pressure ejection system for reliably delivering picolitre volumes |
publisher |
Nature Portfolio |
publishDate |
2017 |
url |
https://doaj.org/article/1d30c7d3322840d9baf96af0c2d7ff61 |
work_keys_str_mv |
AT cjforman openspritzeranopenhardwarepressureejectionsystemforreliablydeliveringpicolitrevolumes AT htomes openspritzeranopenhardwarepressureejectionsystemforreliablydeliveringpicolitrevolumes AT bmbobo openspritzeranopenhardwarepressureejectionsystemforreliablydeliveringpicolitrevolumes AT rjburman openspritzeranopenhardwarepressureejectionsystemforreliablydeliveringpicolitrevolumes AT mjacobs openspritzeranopenhardwarepressureejectionsystemforreliablydeliveringpicolitrevolumes AT tbaden openspritzeranopenhardwarepressureejectionsystemforreliablydeliveringpicolitrevolumes AT jvraimondo openspritzeranopenhardwarepressureejectionsystemforreliablydeliveringpicolitrevolumes |
_version_ |
1718389002689576960 |