Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery

Abstract This study evaluated the accuracy of total keratometry (TK) and standard keratometry (K) for intraocular lens (IOL) power calculation in eyes treated with femtosecond laser-assisted cataract surgery. The retrospective study included a retrospective analysis of data from 62 patients (91 eyes...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Soyoung Ryu, Ikhyun Jun, Tae-im Kim, Kyoung Yul Seo, Eung Kweon Kim
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/1e156ab580a14d8da17728d9845699df
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:1e156ab580a14d8da17728d9845699df
record_format dspace
spelling oai:doaj.org-article:1e156ab580a14d8da17728d9845699df2021-12-02T16:04:18ZPrediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery10.1038/s41598-021-92354-12045-2322https://doaj.org/article/1e156ab580a14d8da17728d9845699df2021-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-92354-1https://doaj.org/toc/2045-2322Abstract This study evaluated the accuracy of total keratometry (TK) and standard keratometry (K) for intraocular lens (IOL) power calculation in eyes treated with femtosecond laser-assisted cataract surgery. The retrospective study included a retrospective analysis of data from 62 patients (91 eyes) who underwent uneventful femtosecond laser-assisted cataract surgery with Artis PL E (Cristalens Industrie, Lannion, France) IOL implantation by a single surgeon between May 2020 and December 2020 in Severance Hospital, Seoul, South Korea. The new IOLMaster 700 biometry device (Carl Zeiss Meditec, Jena, Germany) was used to calculate TK and K. The mean absolute error (MAE), median absolute error (MedAE), and the percentages of eyes within prediction errors of ± 0.25 D, ± 0.50 D, and ± 1.00 D were calculated for all IOL formulas (SRK/T, Hoffer-Q, Haigis, Holladay 1, Holladay 2, and Barrett Universal II). There was strong agreement between K and TK (intraclass correlation coefficient = 0.99), with a mean difference of 0.04 D. For all formulas, MAE tended to be lower for TK than for K, and relatively lower MAE and MedAE values were observed for SRK/T and Holladay 1. Furthermore, for all formulas, a greater proportion of eyes fell within ± 0.25 D of the predicted postoperative spherical equivalent range in the TK group than in the K group. However, differences in MAEs, MedAEs, and percentages of eyes within the above prediction errors were not statistically significant. In conclusion, TK and K exhibit comparable performance for refractive prediction in eyes undergoing femtosecond laser-assisted cataract surgery.Soyoung RyuIkhyun JunTae-im KimKyoung Yul SeoEung Kweon KimNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Soyoung Ryu
Ikhyun Jun
Tae-im Kim
Kyoung Yul Seo
Eung Kweon Kim
Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery
description Abstract This study evaluated the accuracy of total keratometry (TK) and standard keratometry (K) for intraocular lens (IOL) power calculation in eyes treated with femtosecond laser-assisted cataract surgery. The retrospective study included a retrospective analysis of data from 62 patients (91 eyes) who underwent uneventful femtosecond laser-assisted cataract surgery with Artis PL E (Cristalens Industrie, Lannion, France) IOL implantation by a single surgeon between May 2020 and December 2020 in Severance Hospital, Seoul, South Korea. The new IOLMaster 700 biometry device (Carl Zeiss Meditec, Jena, Germany) was used to calculate TK and K. The mean absolute error (MAE), median absolute error (MedAE), and the percentages of eyes within prediction errors of ± 0.25 D, ± 0.50 D, and ± 1.00 D were calculated for all IOL formulas (SRK/T, Hoffer-Q, Haigis, Holladay 1, Holladay 2, and Barrett Universal II). There was strong agreement between K and TK (intraclass correlation coefficient = 0.99), with a mean difference of 0.04 D. For all formulas, MAE tended to be lower for TK than for K, and relatively lower MAE and MedAE values were observed for SRK/T and Holladay 1. Furthermore, for all formulas, a greater proportion of eyes fell within ± 0.25 D of the predicted postoperative spherical equivalent range in the TK group than in the K group. However, differences in MAEs, MedAEs, and percentages of eyes within the above prediction errors were not statistically significant. In conclusion, TK and K exhibit comparable performance for refractive prediction in eyes undergoing femtosecond laser-assisted cataract surgery.
format article
author Soyoung Ryu
Ikhyun Jun
Tae-im Kim
Kyoung Yul Seo
Eung Kweon Kim
author_facet Soyoung Ryu
Ikhyun Jun
Tae-im Kim
Kyoung Yul Seo
Eung Kweon Kim
author_sort Soyoung Ryu
title Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery
title_short Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery
title_full Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery
title_fullStr Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery
title_full_unstemmed Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery
title_sort prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/1e156ab580a14d8da17728d9845699df
work_keys_str_mv AT soyoungryu predictionaccuracyofconventionalandtotalkeratometryforintraocularlenspowercalculationinfemtosecondlaserassistedcataractsurgery
AT ikhyunjun predictionaccuracyofconventionalandtotalkeratometryforintraocularlenspowercalculationinfemtosecondlaserassistedcataractsurgery
AT taeimkim predictionaccuracyofconventionalandtotalkeratometryforintraocularlenspowercalculationinfemtosecondlaserassistedcataractsurgery
AT kyoungyulseo predictionaccuracyofconventionalandtotalkeratometryforintraocularlenspowercalculationinfemtosecondlaserassistedcataractsurgery
AT eungkweonkim predictionaccuracyofconventionalandtotalkeratometryforintraocularlenspowercalculationinfemtosecondlaserassistedcataractsurgery
_version_ 1718385257990848512