Features of Surgical Correction of Spontaneous Luxation of the Complex “IOL Posterior Chamber – Capsular Bag”
Luxation of intraocular lens in capsular bag several years after cataract surgery leads to a decrease in visual function and requires surgical treatment.Aim: to determine effectiveness of various types of surgical treatment of late spontaneous dislocations of IOL in capsular bag.Methods. Analysis of...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | RU |
Publicado: |
Scientific Сentre for Family Health and Human Reproduction Problems
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/1e5a5ff44add4be4bed17c9f17d73fbd |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:1e5a5ff44add4be4bed17c9f17d73fbd |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:1e5a5ff44add4be4bed17c9f17d73fbd2021-11-23T06:14:42ZFeatures of Surgical Correction of Spontaneous Luxation of the Complex “IOL Posterior Chamber – Capsular Bag”2541-94202587-959610.29413/ABS.2019-4.4.16https://doaj.org/article/1e5a5ff44add4be4bed17c9f17d73fbd2019-08-01T00:00:00Zhttps://www.actabiomedica.ru/jour/article/view/2130https://doaj.org/toc/2541-9420https://doaj.org/toc/2587-9596Luxation of intraocular lens in capsular bag several years after cataract surgery leads to a decrease in visual function and requires surgical treatment.Aim: to determine effectiveness of various types of surgical treatment of late spontaneous dislocations of IOL in capsular bag.Methods. Analysis of 123 case histories of patients with late IOL dislocation, operated in 2013–2015, was made. First group included patients with replaced IOLs dislocated into pupillary lens. Second group consisted of patients who underwent reposition and suture of IOL to iris. Examination was made before operation and 6–12 months after operation. Results. The average term from moment of IOL implantation to its luxation was 8.78 ± 4.85 years. II degree of dislocation was detected in 74 % of patients, III degree of dislocation – in 10 %, and IV degree – in 16 % of patients.Uncorrected visual acuity was reduced to 0.15 ± 0.16; best corrected visual acuity to 0.31 ± 0.26. In 83.7 % of patients a pseudoexfoliation syndrome was detected. In 62.6 % of patients IOL luxation was accompanied byhydrodynamic disturbances. Best corrected visual acuity in period from 6 to 12 months after surgery was 0.40 ± 0.24, and after IOL reposition – 0.49 ± 0.22. In addition, after IOL replacement a significant increase in postoperative astigmatism was noted from –0.44 ± 0.84 to –1.96 ± 1.60 D (p < 0.001).Conclusion. As a result of surgical treatment of late spontaneous IOL dislocations in both groups increase in distance uncorrected and best corrected visual acuity was noted. Insufficient visual functions after surgical treatment were caused by concomitant pathology as well as increased postoperative astigmatism.O. P. MishchenkoN. A. SenchenkoA. G. ShchukoScientific Сentre for Family Health and Human Reproduction Problemsarticleiol late luxationiol dislocationpseudoexfoliative syndromecataract surgeryScienceQRUActa Biomedica Scientifica, Vol 4, Iss 4, Pp 108-112 (2019) |
institution |
DOAJ |
collection |
DOAJ |
language |
RU |
topic |
iol late luxation iol dislocation pseudoexfoliative syndrome cataract surgery Science Q |
spellingShingle |
iol late luxation iol dislocation pseudoexfoliative syndrome cataract surgery Science Q O. P. Mishchenko N. A. Senchenko A. G. Shchuko Features of Surgical Correction of Spontaneous Luxation of the Complex “IOL Posterior Chamber – Capsular Bag” |
description |
Luxation of intraocular lens in capsular bag several years after cataract surgery leads to a decrease in visual function and requires surgical treatment.Aim: to determine effectiveness of various types of surgical treatment of late spontaneous dislocations of IOL in capsular bag.Methods. Analysis of 123 case histories of patients with late IOL dislocation, operated in 2013–2015, was made. First group included patients with replaced IOLs dislocated into pupillary lens. Second group consisted of patients who underwent reposition and suture of IOL to iris. Examination was made before operation and 6–12 months after operation. Results. The average term from moment of IOL implantation to its luxation was 8.78 ± 4.85 years. II degree of dislocation was detected in 74 % of patients, III degree of dislocation – in 10 %, and IV degree – in 16 % of patients.Uncorrected visual acuity was reduced to 0.15 ± 0.16; best corrected visual acuity to 0.31 ± 0.26. In 83.7 % of patients a pseudoexfoliation syndrome was detected. In 62.6 % of patients IOL luxation was accompanied byhydrodynamic disturbances. Best corrected visual acuity in period from 6 to 12 months after surgery was 0.40 ± 0.24, and after IOL reposition – 0.49 ± 0.22. In addition, after IOL replacement a significant increase in postoperative astigmatism was noted from –0.44 ± 0.84 to –1.96 ± 1.60 D (p < 0.001).Conclusion. As a result of surgical treatment of late spontaneous IOL dislocations in both groups increase in distance uncorrected and best corrected visual acuity was noted. Insufficient visual functions after surgical treatment were caused by concomitant pathology as well as increased postoperative astigmatism. |
format |
article |
author |
O. P. Mishchenko N. A. Senchenko A. G. Shchuko |
author_facet |
O. P. Mishchenko N. A. Senchenko A. G. Shchuko |
author_sort |
O. P. Mishchenko |
title |
Features of Surgical Correction of Spontaneous Luxation of the Complex “IOL Posterior Chamber – Capsular Bag” |
title_short |
Features of Surgical Correction of Spontaneous Luxation of the Complex “IOL Posterior Chamber – Capsular Bag” |
title_full |
Features of Surgical Correction of Spontaneous Luxation of the Complex “IOL Posterior Chamber – Capsular Bag” |
title_fullStr |
Features of Surgical Correction of Spontaneous Luxation of the Complex “IOL Posterior Chamber – Capsular Bag” |
title_full_unstemmed |
Features of Surgical Correction of Spontaneous Luxation of the Complex “IOL Posterior Chamber – Capsular Bag” |
title_sort |
features of surgical correction of spontaneous luxation of the complex “iol posterior chamber – capsular bag” |
publisher |
Scientific Сentre for Family Health and Human Reproduction Problems |
publishDate |
2019 |
url |
https://doaj.org/article/1e5a5ff44add4be4bed17c9f17d73fbd |
work_keys_str_mv |
AT opmishchenko featuresofsurgicalcorrectionofspontaneousluxationofthecomplexiolposteriorchambercapsularbag AT nasenchenko featuresofsurgicalcorrectionofspontaneousluxationofthecomplexiolposteriorchambercapsularbag AT agshchuko featuresofsurgicalcorrectionofspontaneousluxationofthecomplexiolposteriorchambercapsularbag |
_version_ |
1718416930354757632 |